No, you cannot disable the default behavior where the Blackfly S camera prioritizes Vaux (Line 3 of the GPIO connector) over USB/PoE power via software, firmware, or configuration settings. This is a hardware-level power priority design, not a configurable feature.
Here's why and what you need to know:
1. Hardware-Powered Priority (Not Configurable)
- The Blackfly S uses a diode-ORing circuit (or equivalent power-path management IC) that always prioritizes Vaux (12V) over USB/PoE.
- When voltage is present on Vaux (Line 3), the camera automatically and exclusively draws power from it, ignoring USB/PoE. This is intentional for industrial reliability (e.g., to prevent brownouts if USB/PoE is unstable).
- There is no register, API call, or firmware setting to override this behavior. It’s fixed in the camera's power management circuitry.
2. Why This Design?
- Vaux is a dedicated power input, not a signal line. Its primary purpose is to allow direct connection to an external 12V power source (e.g., for high-current accessories or to bypass USB/PoE limitations).
- Teledyne assumes that if you connect 12V to Vaux, you intend to power the camera from it. This avoids conflicts or unexpected behavior in industrial setups.
3. Your Only Options
If you need to power the camera via USB/PoE even when Vaux is connected, you must:
- Physically disconnect Vaux (Line 3) when using USB/PoE.
Example: Use a relay or manual switch to cut power to Vaux when USB/PoE is active.
- Never apply voltage to Vaux when USB/PoE is the intended power source.
Note: Leaving Vaux unconnected (floating) is safe and allows USB/PoE to power the camera.
4. Critical Warnings
- Do not repurpose Vaux as a signal line. Applying voltage here (even if <12V) will attempt to power the camera. If your external device supplies power to Vaux unintentionally (e.g., a sensor with a 12V output), it will disable USB/PoE power and may damage the camera or the external device.
- Never back-power the camera via GPIO. If Vaux is connected to a non-12V source (e.g., a logic signal), it can cause irreversible damage.
5. Workaround for Specific Use Cases
If you need to use Vaux for non-power purposes (e.g., triggering):
- Use Line 2 (GPO) or Line 4 (GPI) instead. These are true GPIOs configurable via software.
- If you must use Line 3 (Vaux), isolate it from power sources:
- Add a series diode (e.g., Schottky) to block back-powering.
- Use an optocoupler or transistor circuit to avoid direct electrical connection.
- This is complex and not recommended unless absolutely necessary.
Key Documentation Reference
Teledyne FLIR Blackfly S User Manual (Section 3.4.1):
"The camera can be powered via the GPIO connector... If power is supplied via the GPIO connector, the camera will draw power from the GPIO connector and not from the USB or Power over Ethernet (PoE) port."
(No mention of software overrides—this behavior is hardware-enforced.)
Recommendation
- For USB/PoE operation: Keep Vaux unconnected (leave the pin floating).
- If Vaux must be connected (e.g., for external accessories), use a power switch to disconnect it when USB/PoE is active.
- Never apply voltage to Vaux unless you want the camera to use it as the sole power source.
This behavior is consistent across all Blackfly S models (e.g., BFS-PGE-16S2M, BFS-U3-51S5C). If your application requires dynamic power-source switching, consider adding external power management hardware (e.g., a power multiplexer IC) to your system design. For further validation, consult Teledyne’s Application Note #146 or contact their technical support.