combine this into one clear statement: 4. After all lockout devices are verified,…
- User
combine this into one clear statement:
-
After all lockout devices are verified, attempt to start the cooling tower. The cooling tower should NOT start. After VERIFICATION, move to next step.
-
Verify the water tower is OFF, no pumps should be running (audible), no water should be flowing (visible and audible). Touch PLC screen or try power switch (temporarily remove LOTO device for test) to confirm no operation starts. After VERIFICATION, move to next step.
-
Assistant
Here's the combined statement:
Verify the cooling tower is OFF by confirming no pumps are running (audible), no water is flowing (visible and audible), and all lockout devices are properly installed. Test by touching the PLC screen or temporarily removing the LOTO device to try the power switch - the cooling tower should NOT start under any circumstances. After complete verification, move to the next step.
- User
does this sound cluncky: COOLING WATER ON/OFF button on E-02 Control Panel PLC touch screen located in Building 1 Boiler Room.
Assistant
Yes, it does sound a bit clunky. Here are some clearer alternatives:
Option 1: Use the COOLING WATER ON/OFF button on the E-02 Control Panel PLC touch screen in Building 1 Boiler Room.
Option 2: Access the COOLING WATER ON/OFF button via the E-02 Control Panel PLC touch screen located in the Building 1 Boiler Room.
Option 3: The COOLING WATER ON/OFF button is found on the E-02 Control Panel PLC touch screen in the Building 1 Boiler Room.
The main issues with the original were the lack of connecting words and the awkward placement of "located."
- User
I need it to be for "Energy Isolation Point/Location"
Assistant
For an "Energy Isolation Point/Location" entry, you'd want it more concise and direct:
E-02 Control Panel PLC touch screen, Building 1 Boiler Room - COOLING WATER ON/OFF button
Or even simpler:
E-02 Control Panel (Building 1 Boiler Room) - COOLING WATER ON/OFF button
This format clearly identifies the location first, then specifies the exact control point.
- User
and then how would the Isolation Method and Lockout device look?
Assistant
For the Isolation Method and Lockout Device, it would typically look like:
Isolation Method: Turn COOLING WATER ON/OFF button to OFF position
Lockout Device: PLC screen lockout cover/box or electrical panel lockout (depending on your specific LOTO hardware)
Or if you're using a different approach:
Isolation Method: Disconnect power to E-02 Control Panel
Lockout Device: Circuit breaker lockout or electrical disconnect lockout
The specific lockout device would depend on what LOTO hardware your facility uses for PLC/touch screen controls - some use covers that go over the screen, others lock out the electrical supply to the panel.
- User
so you would put this in the testing a verification of lockout/try section and not in the table of isolation steps
Assistant
Exactly! The testing/verification section is where you would include the step about trying the COOLING WATER ON/OFF button to confirm it doesn't work.
The table of isolation steps would show:
- Energy Isolation Point/Location
- Isolation Method
- Lockout Device
The testing/verification section would include something like: "Attempt to operate the COOLING WATER ON/OFF button on the E-02 Control Panel PLC touch screen - the system should NOT respond or start."
This follows proper LOTO procedure: first you isolate and lock out (table), then you test to verify the lockout is effective (verification section).
- User
so something like this: 1. Before working on E-02 Cooling Tower, ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during the lockout. 2. Verify the cooling tower is OFF by confirming no pumps are running (audible), no water is flowing (visible and audible). Try to turn on cooling tower from the PLC screen - the cooling tower should NOT start. Return PLC to OFF. After complete verification, move to the next step.
Assistant
Yes, that's much better! Just a couple of minor tweaks for clarity:
1. Before working on E-02 Cooling Tower, ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during the lockout.
2. Verify the cooling tower is OFF by confirming no pumps are running (audible) and no water is flowing (visible and audible). Attempt to turn on the cooling tower from the PLC screen - the cooling tower should NOT start. Confirm PLC remains in OFF position. After complete verification, move to the next step.
The main changes:
- Added "and" between the two verification checks
- Changed "Try to turn on" to "Attempt to turn on" (more formal/procedural language)
- Changed "Return PLC to OFF" to "Confirm PLC remains in OFF position" (since it should already be OFF from your lockout)
This flows well and clearly separates the coordination step from the verification testing step.
- User
here is there entire try section so far:
- Before working on E-02 Cooling Tower, ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during the lockout.
- Verify the cooling tower is OFF by confirming no pumps are running (audible), no water is flowing (visible and audible). Try to turn on cooling tower from the PLC screen - the cooling tower should NOT start. Return PLC to OFF. After complete verification, move to the next step.
- Using the Left-Hand Rule, try to turn on each disconnect. No motion or energization should be possible. Pull firmly on lock/hasp to confirm each lock cannot be opened.
- Try to open City Water Supply Valve. Valve should not open. Pull firmly on lock/hasp to confirm lock cannot be opened. Verify that water flow to the cooling tower has stopped. After VERIFICATION, move to next step.
- If the job DOES NOT involve any exposed wiring and VERIFICATION of LOCKOUT/TRY is completed, proceed to perform the job. If the job involves any exposed wiring move to next step.
- If exposed wiring is involved or if electrical components are part of the job, use a voltage measurement device to test for ZERO ENERGY. VERIFY that there is no electrical voltage flowing to or from the equipment. After VERIFICATION, move to next step.
- After ALL applicable TESTING steps have been VERIFIED (all energy sources isolated), work may proceed.
Assistant
This looks comprehensive and well-structured! Here are a few minor suggestions for consistency and clarity:
Step 2: Change "Try to turn on cooling tower" to "Attempt to turn on cooling tower" to match the formal tone of the other steps.
Step 3: Consider adding "After verification" at the end for consistency with other steps.
Step 4: The flow is good - you're testing the valve operation and confirming the physical lock security.
Step 6: You might want to specify "qualified person" or "authorized personnel" for voltage testing, as this typically requires specific training/certification.
Overall structure: The progression from operational verification → mechanical lockouts → water supply → electrical testing → work authorization is logical and follows good LOTO practices.
The section effectively covers all energy sources (electrical, mechanical, and water/hydraulic) and includes both functional testing and physical lock verification. This should provide thorough confirmation that the cooling tower is properly isolated before work begins.
- User
but i was told by a mechanic they want it to be a habit to turn off the tower first
Assistant
Ah, that makes perfect sense! The mechanic is right - you want to establish the habit of always turning off the equipment first before applying lockout. Here's how you could revise step 2:
2. Turn OFF the cooling tower using the PLC screen. Verify the cooling tower is OFF by confirming no pumps are running (audible) and no water is flowing (visible and audible). Attempt to turn on cooling tower from the PLC screen - the cooling tower should NOT start. Return PLC to OFF position. After complete verification, move to the next step.
This way the sequence becomes:
- Coordinate with operations
- Turn off first → then verify it's off → then test that lockout is effective
- Test mechanical disconnects
- Test water valve
- Continue with remaining steps...
This builds the good safety habit of always ensuring the equipment is in the off state before proceeding with lockout verification.
- User
the issue is the template does not acutally havea shutdown section
Assistant
Ah, I see the issue! The template jumps straight to lockout/try verification without a proper shutdown procedure section.
You have a few options:
Option 1: Add a shutdown step at the beginning of the try section: 1. Shut down E-02 Cooling Tower using the PLC screen and allow to come to complete stop. 2. Before working on E-02 Cooling Tower, ENSURE that manufacturing equipment...
Option 2: Modify step 2 to include the shutdown: 2. Shut down the cooling tower using the PLC screen if not already off. Verify the cooling tower is OFF by confirming...
Option 3: Suggest adding a "SHUTDOWN PROCEDURE" section to the template before the "LOCKOUT/TRY" section.
The mechanic is absolutely right - proper LOTO should always include: Shutdown → Lockout → Try/Verify. If the template is missing the shutdown step, that's a gap that should be addressed either by modifying this procedure or updating the template for future use.
Which approach would work best with your current template format?
- User
so i can add maybe a shutdown step in the header
Assistant
Exactly! Adding a shutdown step in the header section would be perfect. You could add something like:
SHUTDOWN PROCEDURE: Turn OFF E-02 Cooling Tower using the COOLING WATER ON/OFF button on the PLC screen and allow equipment to come to complete stop before proceeding with lockout.
Then your lockout/try section would flow naturally from there, starting with the coordination step and moving into verification that the shutdown was effective.
This way you're building that good safety habit the mechanic mentioned - always shutdown first, then lockout, then verify. It also makes the procedure more complete and follows proper LOTO sequence without having to modify the existing template structure.
- User
well there is a lockout application process. can i add it here?
Assistant
Absolutely! If there's a "Lockout Application Process" section in the template, that would be the perfect place to include the shutdown step.
The logical flow would be:
LOCKOUT APPLICATION PROCESS:
- Turn OFF E-02 Cooling Tower using the COOLING WATER ON/OFF button on the PLC screen and allow equipment to come to complete stop.
- [Apply lockout devices per the isolation table]
- [Any other lockout application steps]
LOCKOUT/TRY VERIFICATION:
- Before working on E-02 Cooling Tower, ENSURE that manufacturing equipment...
- Verify the cooling tower is OFF by confirming no pumps are running...
This keeps the proper sequence: Shutdown → Apply Lockouts → Verify/Test, and fits within the existing template structure. It also reinforces that habit the mechanic wants - always turn it off first before applying any lockout devices.
- User
heres the template:
Assistant
I don't see the template in your message - it looks like it may not have come through. Could you paste the template again? I'd be happy to help you figure out where to add the shutdown step within the existing template structure.
- User
- Fill out all necessary permits needed to perform scope of work BEFORE beginning any work. (LOTO, Safe Work are always required. If entire room is not to remain down, a supplemental LOTO procedure may be required and you must engage your supervisor.)
- Perform a Pre-Job discussion with team involved with performing the work.
- Notify all affected personnel (operators) not directly working on equipment before starting the LOCKOUT PROCEDURE. Be sure to verify process has been shut down following operating procedure. Clarify power will be totally isolated to a de-energized condition and operations will not be available. Document with operator signature on the LOTO permit.
- Isolate energy sources at control points and apply Lockout devices, locks, and tags following the written procedure steps below.
- All locks applied to isolation points must be personally identified and in the “SECURED” position.
- Authorized master lock holder must perform a group LOCKOUT controlling the key(s) for each isolation lock applied.
- DO NOT allow work to be performed by anyone who has not applied own personal lock to the group LOCKOUT BOX. where can i add 1 and 2 from the verify section
Assistant
Looking at your template, I can see a couple of good places to add the shutdown and initial verification:
Option 1 - Modify Step 3: "3. Notify all affected personnel (operators) not directly working on equipment before starting the LOCKOUT PROCEDURE. Be sure to verify process has been shut down following operating procedure. Turn OFF E-02 Cooling Tower using the PLC screen and allow to come to complete stop. ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during the lockout. Clarify power will be totally isolated to a de-energized condition and operations will not be available. Document with operator signature on the LOTO permit."
Option 2 - Add as Step 3a: "3a. Turn OFF E-02 Cooling Tower using the PLC screen and allow to come to complete stop. ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during the lockout."
Option 3 - Expand Step 4: "4. Turn OFF E-02 Cooling Tower using the PLC screen and allow to come to complete stop. ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system. Isolate energy sources at control points and apply Lockout devices, locks, and tags following the written procedure steps below."
I think Option 1 works best since Step 3 already mentions verifying the process is shut down.
- User
no the 1 -7 i gave is the lockout application
Assistant
Ah, I see! So steps 1-7 you provided are the "Lockout Application" section of the template.
You could add your shutdown and coordination steps from the verify section into the Lockout Application section like this:
Between steps 3 and 4, add: "3a. Turn OFF E-02 Cooling Tower using the PLC screen and allow to come to complete stop. 3b. ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during the lockout."
Or modify step 4 to include them: "4. Turn OFF E-02 Cooling Tower using the PLC screen and allow to come to complete stop. ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during the lockout. Isolate energy sources at control points and apply Lockout devices, locks, and tags following the written procedure steps below."
This way the shutdown happens right before you start applying the actual lockout devices, which follows the proper sequence the mechanic wanted.
- User
basically number 3 covers the PLC screen
Assistant
You're absolutely right! Step 3 already covers the PLC screen shutdown when it says "Be sure to verify process has been shut down following operating procedure."
So you really just need to add the coordination step about manufacturing equipment. You could add it as:
Step 3a: "ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during the lockout."
Or incorporate it into step 3 by expanding it slightly to include both the shutdown verification and the coordination check.
The PLC shutdown is already covered in step 3, so you don't need to duplicate that part.
- User
i just put it as its onwn atep:
- Fill out all necessary permits needed to perform scope of work BEFORE beginning any work. (LOTO, Safe Work are always required. If entire room is not to remain down, a supplemental LOTO procedure may be required and you must engage your supervisor.)
- Perform a Pre-Job discussion with team involved with performing the work.
- CAUTION: Before working on E-02 Cooling Tower, ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during the lockout.
- Notify all affected personnel (operators) not directly working on equipment before starting the LOCKOUT PROCEDURE. Be sure to verify process has been shut down following operating procedure. Clarify power will be totally isolated to a de-energized condition and operations will not be available. Document with operator signature on the LOTO permit.
- Isolate energy sources at control points and apply Lockout devices, locks, and tags following the written procedure steps below.
- All locks applied to isolation points must be personally identified and in the “SECURED” position.
- Authorized master lock holder must perform a group LOCKOUT controlling the key(s) for each isolation lock applied.
- DO NOT allow work to be performed by anyone who has not applied own personal lock to the group LOCKOUT BOX.
Assistant
Perfect! That works really well. Making it its own step with "CAUTION:" gives it the proper emphasis and ensures it won't be overlooked. The flow is logical:
- Permits
- Pre-job discussion
- CAUTION about coordination ← Your addition
- Notify operators and verify shutdown
- Apply lockouts
- Secure locks
- Group lockout
- Personal locks required
This puts the coordination check right where it should be - after the team discussion but before you start the actual lockout process. The "CAUTION:" formatting makes it stand out as a critical safety consideration that could affect other operations.
Good solution!
- User
if the LOTO is divded into jobs, each job section has the lockout steps and the verification section. shoul dit also have this red section?
Assistant
Yes, absolutely! If the LOTO is divided into separate job sections, each job section should include this coordination step (step 3 with the CAUTION) because:
-
Different jobs may have different coordination requirements - Job A might affect one set of manufacturing equipment while Job B affects different equipment
-
Jobs might be performed at different times - The coordination check needs to happen right before each specific job starts
-
Different teams might perform different jobs - Each team needs to be aware of their specific coordination requirements
-
Safety redundancy - It's better to have this critical safety check repeated than missed
You could either:
- Include the full step 3 in each job section, or
- Modify it to be job-specific: "CAUTION: Before beginning [Job X], ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during this phase of work."
This ensures that no matter which job someone is performing, they're reminded to coordinate with operations first.
-
- User
how do i modifiy ONE LOTO APPLICATION process to address shutting down certain things from the PLC first. For example, the is a section on pumps and just the specific pump should be shut off first from the plc
Assistant
You can modify the Lockout Application process to include equipment-specific shutdown steps. Here are a few approaches:
Option 1 - Add a new step after step 4: "4a. For equipment with PLC controls, shut down the specific equipment from the PLC screen BEFORE applying physical lockouts (e.g., turn OFF specific pump from PLC before locking out pump disconnect)."
Option 2 - Modify step 5 to include shutdown: "5. First, shut down specific equipment from PLC controls where applicable. Then isolate energy sources at control points and apply Lockout devices, locks, and tags following the written procedure steps below."
Option 3 - Make it more specific: "4a. Where equipment has PLC controls, use the following sequence:
- Turn OFF the specific equipment from the PLC screen
- Allow equipment to come to complete stop
- Then proceed to isolate and lockout physical energy sources"
This way, for your pump section, workers would know to turn off that specific pump from the PLC first, then apply the physical lockouts to the pump disconnect. It builds that good habit the mechanic wanted while keeping it general enough to apply to any PLC-controlled equipment in the procedure.
- User
how is this (and I will update the operating procedure to have more spefic instructions:
- Fill out all necessary permits needed to perform scope of work BEFORE beginning any work. (LOTO, Safe Work are always required. If entire room is not to remain down, a supplemental LOTO procedure may be required and you must engage your supervisor.)
- Perform a Pre-Job discussion with team involved with performing the work.
- CAUTION: Before working on E-02 Cooling Tower, ENSURE that manufacturing equipment in Building 1 is not operating or dependent on the cooling water system during the lockout.
- Notify all affected personnel (operators) not directly working on equipment before starting the LOCKOUT PROCEDURE. Be sure to verify process has been shut down following operating procedure. Clarify power will be totally isolated to a de-energized condition and operations will not be available. Document with operator signature on the LOTO permit.
- For equipment with PLC controls, shut down the specific equipment from the PLC screen BEFORE applying physical lockouts (e.g., turn OFF specific pump from PLC before locking out pump disconnect)."
- Isolate energy sources at control points and apply Lockout devices, locks, and tags following the written procedure steps below.
- All locks applied to isolation points must be personally identified and in the “SECURED” position.
- Authorized master lock holder must perform a group LOCKOUT controlling the key(s) for each isolation lock applied.
- DO NOT allow work to be performed by anyone who has not applied own personal lock to the group LOCKOUT BOX.
Assistant
That looks excellent! The flow is perfect:
- Permits
- Pre-job discussion
- Coordination check
- Operator notification and general shutdown verification
- Specific PLC shutdown step ← Your addition
- Physical lockout application
- Lock security
- Group lockout
- Personal locks
Step 5 is well-placed - it comes after the general shutdown verification but before applying physical lockouts, which is exactly the right sequence. The example with the pump makes it clear and practical.
Your plan to update the operating procedure with more specific instructions is smart too. That way this general step in the LOTO Application covers the principle, while the detailed operating procedure can specify exactly which PLC screens to use, which buttons to press, etc.
This gives workers the habit-building reminder the mechanic wanted while keeping the LOTO Application section at the right level of detail. Good solution!