Okay, let's break down the troubleshooting steps for your Sunsynk hybrid inverter in your off-grid setup with a Hoymiles microinverter connected to the grid input (which is unusual but let's address it) and a generator input that isn't functioning. We'll focus on likely settings and potential wiring issues.
Understanding Your Setup
- Off-Grid with Battery: The Sunsynk is primarily running from your solar panels and battery.
- Hoymiles Microinverter (Connected to Grid Input): This is where things get a bit tricky and potentially problematic. Microinverters are designed to synchronize with a stable AC grid. Your Sunsynk's "grid" input is essentially acting as that AC grid, but only when the Sunsynk outputs AC power through that port. This is crucial.
- Generator Input Not Showing Production: This is a separate but important issue.
Troubleshooting Steps and Settings to Check:
-
Hoymiles Microinverter Issue:
-
Sunsynk's Grid Output Settings: This is the most important area to investigate for the Hoymiles.
-
Grid Mode: Ensure the Sunsynk's "Grid Mode" (or similar terminology) is set appropriately. It's likely set to "Off-Grid," but you need to tell the Sunsynk to output AC power on the Grid port, so the Hoymiles can sync to it. Look for settings like:
- Grid Tied (with Export): This is probably not what you want, as it would likely attempt to export excess power to a non-existent grid.
- Grid Tied (Zero Export): This might work, but you'd need to carefully monitor if the Sunsynk can properly manage the Hoymiles' output to prevent backfeeding.
- PV Priority: If there's a setting to prioritize PV input and feed that power to the Grid output, that could be suitable. This is the key to making the Hoymiles think it's connected to a normal grid.
- Check AC voltage: Ensure the voltage on the AC output/grid is set at 230Vac (or whatever local voltage standard).
-
AC Output Voltage and Frequency: Verify that the AC output voltage and frequency settings on the Sunsynk match the requirements of the Hoymiles microinverter (typically 230V / 50Hz or 120V / 60Hz depending on your region).
-
Grid Parallel Function: If the inverter has this function enable it.
-
Wiring/Connection Issues: Double-check the wiring between the Hoymiles and the Sunsynk's grid input. Make sure the polarity is correct.
-
Hoymiles Compatibility: Confirm that the Hoymiles microinverter is compatible with the Sunsynk's output voltage range and frequency.
-
Why This is Complicated: The Hoymiles is expecting a stable, consistent AC grid. The Sunsynk is creating that grid, but it may not be perfectly stable at all times (especially with fluctuating solar input). This is why this setup is not ideal.
-
Best to connect on AC output: Check if you can safely connect the microinverter to the AC output instead of the grid output.
-
Generator Input Issue:
-
Generator Settings: Look for settings related to the generator input. These might include:
- Generator Type: Select the correct type of generator (e.g., "Petrol," "Diesel"). If there is an option for "Auto Start" or "Manual Start," check that you know how this function is set up (usually requires additional wiring).
- Voltage and Frequency Range: Verify that the acceptable voltage and frequency range for the generator input are configured correctly to match your generator's specifications. If the generator is outside these limits, the Sunsynk will ignore its output.
- Wattage Limit: Make sure the maximum wattage allowed from the generator is set appropriately.
- Generator Charging Enable: This setting dictates whether the inverter will use the generator's power to charge the battery. Ensure it's enabled if you want this functionality.
-
Generator Connection:
- Wiring: Double-check the wiring between the generator and the Sunsynk. Make sure the polarity is correct.
- Voltage and Frequency: Use a multimeter to verify that the generator is actually producing the correct voltage and frequency while it's running.
- Generator On: Ensure the generator is turned on and producing power.
- Check the Generator Breaker: Make sure the generator's output breaker is on.
- Generator Start Signal (if applicable): If your generator is connected for automatic start/stop, check the signal wire is correctly connected.
-
Sunsynk Display: Does the Sunsynk show any voltage or amperage on the generator input when the generator is running? If not, the Sunsynk may not be "seeing" the generator at all.
-
General Inverter Settings and Checks:
- Firmware: Ensure the Sunsynk's firmware is up to date. Check the manufacturer's website for updates.
- Error Codes: Check for any error codes on the Sunsynk's display. Look up these codes in the manual for troubleshooting information.
- Battery Settings: Review your battery settings to ensure they are correctly configured for your battery type (e.g., Lithium, Lead-Acid). Incorrect battery settings can affect the inverter's overall behavior. Specifically, check the charging voltage and current limits.
Important Considerations:
- Sunsynk Manual: The Sunsynk manual is your primary resource. Refer to it for specific settings, wiring diagrams, and troubleshooting information.
- Safety: Work safely. Disconnect power before making any wiring changes.
- Qualified Electrician: If you're not comfortable working with electrical wiring, consult a qualified electrician. Improper wiring can be dangerous and damage your equipment.
- Hoymiles Documentation: Consult the Hoymiles microinverter documentation to see any specific requirements or recommendations for grid-independent operation.
- Consider the Design: It's worth reconsidering the connection of the Hoymiles. A more typical setup would be to connect the solar panels directly to the Sunsynk's DC input and use the Sunsynk's battery charging capabilities.
Example Settings (Based on Common Sunsynk Models):
While I can't give you exact settings without knowing your specific Sunsynk model, here are some examples of the types of settings you should be looking for. These are examples only, don't blindly apply them!
-
Generator:
- Generator Input: Enabled
- Generator Type: Diesel/Petrol (appropriate to your gen)
- Voltage Range: 220-240V (or appropriate for your region)
- Frequency Range: 48-52Hz (or appropriate for your region)
- Max Charging Current: [Set based on your battery specifications and generator capacity]
-
Grid:
- Grid Mode: Off-Grid (or similar)
- AC Output Voltage: 230V (or your region's standard)
- AC Output Frequency: 50Hz (or your region's standard)
- Grid Parallel: enabled if the inverter has this option
Step-by-Step Troubleshooting Approach:
- Hoymiles First: Disconnect the generator input for now to isolate the problem. Focus on getting the Hoymiles working. Go through the "Hoymiles Microinverter Issue" troubleshooting steps above.
- Generator Second: Once you have the Hoymiles behaving (or if you decide to disconnect it and run solely on battery/solar), focus on the generator input. Go through the "Generator Input Issue" steps above.
- Document Everything: As you change settings, write down the original values. This will allow you to easily revert to the previous configuration if needed.
By systematically working through these steps and carefully reviewing your Sunsynk's settings, you should be able to identify the cause of the issues and get your system working properly. Good luck!