I still don't understand. Can you give an example in terms of voltages? For absolute…

  1. User

    I still don't understand. Can you give an example in terms of voltages?

    For absolute voltage level including the audio-frequency noise level (see § 6.6) dBu: absolute voltage level with respect to 0.775 V; dBu0: absolute voltage level with respect to 0.775 V, referred to a point of zero relative level; dBu0s: absolute voltage level with respect to 0.775 V, referred to a point of zero relative level in sound-programme transmission;

  2. Assistant

    Let's break it down using voltage levels.

    Background:

    • dBu: This is a unit of absolute voltage level, referenced to 0.775 volts.
      • For example, 0 dBu = 0.775 V (RMS).
    • dBu0: This is the absolute voltage level (in dBu) referred to a point of zero relative level.

    Understanding Relative Level and Absolute Level

    1. Relative Level (dBr): This is a measure of how much a point in a system is above or below a reference point (the "zero relative level point").

    2. Absolute Voltage Level (dBu): This is a measure of the actual voltage at a point.

    Example with Voltages

    Let's say:

    • The voltage at point X is 1.55 V (RMS).
    • The relative level at X is +6 dBr (meaning X is 6 dB above the reference point).

    Step 1: Convert Voltage to dBu

    First, we need to convert the voltage at X into dBu.

    The formula to convert voltage to dBu is: [ \text{dBu} = 20 \log_{10} \left( \frac{V}{0.775} \right) ] For ( V = 1.55 , \text{V} ): [ \text{dBu} = 20 \log_{10} \left( \frac{1.55}{0.775} \right) = 20 \log_{10} (2) = 6 , \text{dBu} ] So, the absolute voltage level at X is 6 dBu.

    Step 2: Refer the Voltage Level to the Zero Relative Level Point (dBu0)

    To refer this to the zero relative level point, we use the formula: [ \text{dBu0} = \text{dBu} - \text{Relative Level (dBr)} ] Given:

    • dBu = 6 dBu (from Step 1)
    • Relative Level = +6 dBr

    [ \text{dBu0} = 6 , \text{dBu} - (+6 , \text{dBr}) = 0 , \text{dBu0} ]

    Interpretation

    • The voltage at X is 1.55 V, which corresponds to 6 dBu.
    • Since X is 6 dB above the reference point, when we refer the voltage level to the reference point, we get 0 dBu0.

    This means that if we were to measure the signal at the reference point, its voltage level would correspond to 0 dBu0, or 0.775 V.

    Summary

    QuantityValueUnit
    Voltage at X1.55V
    Relative level at X+6dBr
    Absolute level at X6dBu
    Referred to 0 dBr0dBu0

    dBu0s

    • dBu0s is similar to dBu0, but specifically used in the context of sound-programme transmission.

    The key idea is that dBu0 (or dBu0s) allows you to express voltage levels from different points in a system as if they were all measured at the same reference point, making comparisons easier.

    If you have more questions or need further clarification, feel free to ask!