Sure! Let’s clarify the concept of dBm0 and its voltage equivalents (dBu0, dBu0s) with a concrete example using voltages.
Step 1: Understand the units
- dBm: power referenced to 1 mW.
- dBu: voltage referenced to 0.775 V RMS (this corresponds to 1 mW into 600 Ω).
- dBm0: power level referred to a zero relative level point (a reference point in the system).
- dBu0: voltage level referred to a zero relative level point.
- dBu0s: similar to dBu0 but specifically for sound-program transmission.
Step 2: Voltage and power relationship
Power ( P ) in watts is related to voltage ( V ) (RMS) and impedance ( R ) by:
[
P = \frac{V^2}{R}
]
For a 600 Ω system (common in audio):
- 0 dBm = 1 mW = 0.001 W
- Voltage for 0 dBm:
[
V_0 = \sqrt{P \times R} = \sqrt{0.001 \times 600} = \sqrt{0.6} \approx 0.775 \text{ V}
]
This is why 0 dBu = 0.775 V RMS.
Step 3: Example with voltages and relative levels
Imagine a system with a reference point (zero relative level point) and two measurement points:
- At the reference point (call it point T), the voltage level is ( V_T ).
- At another point X, the voltage level is ( V_X ).
Suppose:
- The relative level at point X compared to T is ( L_{XR} = -6 \text{ dBr} ) (meaning the signal at X is 6 dB lower than at T).
- The absolute voltage measured at X is ( V_X = 0.245 \text{ V} ).
Step 4: Convert voltage to dBu
[
L_{XA} = 20 \log_{10} \left(\frac{V_X}{0.775}\right)
]
Calculate:
[
L_{XA} = 20 \log_{10} \left(\frac{0.245}{0.775}\right) = 20 \log_{10} (0.316) \approx 20 \times (-0.5) = -10 \text{ dBu}
]
So, the absolute voltage level at X is -10 dBu.
Step 5: Calculate the voltage level referred to the zero relative level point (dBu0)
Using the formula from the document:
[
L_0 = L_{XA} - L_{XR}
]
[
L_0 = (-10) - (-6) = -10 + 6 = -4 \text{ dBu0}
]
Step 6: Interpret the result
- The voltage level at X is -10 dBu (absolute voltage relative to 0.775 V).
- The relative level at X is -6 dBr (6 dB below the reference point).
- The voltage level referred to the zero relative level point (the reference point T) is -4 dBu0.
This means if you "move" the measurement back to the reference point, the voltage level would be -4 dBu0.
Summary in voltage terms:
| Quantity | Value | Explanation |
|---|
| ( V_X ) | 0.245 V | Measured voltage at point X |
| ( L_{XA} ) (dBu) | -10 dBu | Absolute voltage level at X |
| ( L_{XR} ) (dBr) | -6 dBr | Relative level at X compared to T |
| ( L_0 ) (dBu0) | -4 dBu0 | Voltage level referred to zero level point |
Why is this useful?
- You can compare signals measured at different points by referring them all to the same zero relative level point.
- This is important for consistent measurements, especially when calculating signal-to-noise ratios or system gains/losses.
If you want, I can also show how this works with power (dBm0) or noise levels. Would you like that?