Skip to content
TheChatArchiveThe Chat Archive
Mistralmistral-medium-2505· Mistral AIHugging Face LMArena Human Preference 140K

I am running an underglow business, I have a main kit which goes from controller to a Y…

From a Chatbot Arena battleThe same person sent this prompt to two anonymous models at once. Compare it with o3-2025-04-16’s answer.
  1. User

    I am running an underglow business, I have a main kit which goes from controller to a Y splitter and each side has 100cm, 2m conntector, 180cm, 2m connector and then 80cm

    My leds are 12v and 90/led/m, they are rated for 25W

    tell me the expected

    mA per diode Wattage Amperage expected voltage dropoff, and will I expect yellowing?

    My longest underglow kit will be on one side 110cm, 190cm and 160cm rear. Will I have voltage drop off?

    also answer these generalized questions to my kit

    battery harness, what gauage wire to the controller, what gauge wire to the LED's, what gauge wire between LEDs will be suitable?

  2. Mistral Assistant

    Let's break down your underglow kit specifications and answer your questions step by step.

    1. LED Specifications & Calculations

    • LED Type: 12V, 90 LEDs/meter
    • Power Rating: 25W per strip (assuming this is for a full strip, not per meter)
    • Voltage Drop & Yellowing Concerns

    a) Current per Diode (mA)

    • Total LEDs in 1 meter: 90 LEDs
    • Power per meter (assuming 25W is for the full strip):
      • If the strip is 5 meters (100cm + 2m + 180cm + 2m + 80cm = 5.8m, but likely split), we need to clarify.
      • For simplicity, let's assume 25W is for the entire strip (all segments combined).
      • Current (Amps) = Power (W) / Voltage (V) = 25W / 12V ≈ 2.08A total.
      • Current per LED = Total Current / Total LEDs
        • If total LEDs = 90 LEDs/m × 5m = 450 LEDs → 2.08A / 450 ≈ 4.6mA per LED
        • (This seems low; likely the 25W is per meter, not total.)

    Revised Calculation (Assuming 25W per meter):

    • Current per meter = 25W / 12V ≈ 2.08A per meter
    • Current per LED = 2.08A / 90 ≈ 23mA per LED (More realistic)

    b) Wattage

    • 25W per meter (if that's the rating)
    • Total wattage depends on total length.

    c) Amperage

    • 2.08A per meter (if 25W/m)
    • Total amperage = 2.08A × total meters

    d) Expected Voltage Drop

    • Voltage drop depends on wire gauge and length.
    • 12V LEDs typically tolerate ~10% drop (1.2V) before dimming/yellowing.
    • Longest run (110cm + 190cm + 160cm = 460cm = 4.6m):
      • If using 18AWG wire (~0.02Ω/m), resistance = 4.6m × 0.02Ω ≈ 0.092Ω
      • Voltage drop = Current × Resistance = 2.08A × 0.092Ω ≈ 0.19V (negligible)
      • If using thinner wire (e.g., 22AWG), resistance increases, and drop may exceed 1.2V.

    e) Will You Get Yellowing?

    • Unlikely if using 18AWG or thicker.
    • If voltage drops below ~10.8V, LEDs may dim or yellow.
    • Solution: Use 16AWG or thicker for long runs to minimize drop.

    2. Wire Gauge Recommendations

    a) Battery Harness to Controller

    • Recommended: 12AWG or 10AWG (for high current, low voltage drop)
    • Why? Prevents overheating and ensures stable voltage.

    b) Controller to LEDs

    • Recommended: 16AWG or 14AWG (for runs up to 5m)
    • Why? Balances flexibility and low resistance.

    c) Between LED Strips (Connections)

    • Recommended: 18AWG or 16AWG (for short jumps)
    • Why? Prevents voltage drop between segments.

    3. Summary of Key Points

    ParameterValue
    Current per LED~23mA (if 25W/m)
    Wattage per meter25W
    Amperage per meter~2.08A
    Voltage drop riskLow with 16AWG/18AWG
    Yellowing riskUnlikely if proper gauge used
    Battery to Controller12AWG/10AWG
    Controller to LEDs16AWG/14AWG
    Between LEDs18AWG/16AWG

    Final Recommendation

    • Use 16AWG for long runs (4.6m side) to prevent voltage drop.
    • Avoid thin wires (22AWG+) for long distances.
    • If dimming/yellowing occurs, upgrade to thicker wire or add a secondary power injection.

    Would you like help calculating exact voltage drops for your specific wire lengths?

Responses were produced in different, uncontrolled contexts (system prompts, settings, prior turns). This is not a benchmark.