how do i calculate the failstate of a stonewall in its own direction according to the…
- User
how do i calculate the failstate of a stonewall in its own direction according to the europeean norm
Assistant
Of course. Calculating the failure state of a stonewall in its own plane (out-of-plane failure) according to European Norms is primarily governed by Eurocode 6: Design of masonry structures (EN 1996).
The core principle is to ensure that the Design Action Effect (E_d) is less than or equal to the Design Resistance (R_d).
E_d ≤ R_d
- E_d (Design Action Effect): This is the calculated effect of the loads (like wind) on the wall, magnified by partial safety factors. For out-of-plane failure, this is typically a bending moment or an overturning moment.
- R_d (Design Resistance): This is the calculated strength of the wall, reduced by a partial safety factor for the material. This is the moment resistance of the wall section.
Here is a step-by-step guide to the calculation process.
Step 1: Define Wall Properties and Materials (EN 1996-1-1)
You need to gather the fundamental data about your wall.
-
Geometry:
- Thickness (t): The thickness of the wall in meters (e.g., 0.5 m).
- Height (h): The height of the wall in meters (e.g., 3.0 m).
- Support Conditions: How is the wall supported at the top and bottom? (e.g., simply supported, cantilever, fixed). This determines the effective height (h_ef). For a simple wall supported at the top and bottom,
h_ef = h. For a freestanding wall (cantilever),h_ef = 2h.
-
Material Properties:
- Characteristic Compressive Strength of Masonry (f_k): This depends on the strength of the stone units and the mortar. It can be found in tables in EN 1996-1-1 or determined by testing.
- Characteristic Flexural Strength of Masonry (f_xk): This is the most important property for out-of-plane failure. It has two values:
- f_xk1: Flexural strength with the plane of failure parallel to the bed joints (horizontal joints). This is usually the critical value for a wall bending vertically.
- f_xk2: Flexural strength with the plane of failure perpendicular to the bed joints.
- Self-Weight (γ_masonry): The density of the stonework in kN/m³ (e.g., 22 kN/m³).
-
Partial Safety Factors (γ_M):
- This factor reduces the material strength to a design value. It is found in the National Annex for your country. For masonry,
γ_Mis often in the range of 2.0 to 3.0.
- This factor reduces the material strength to a design value. It is found in the National Annex for your country. For masonry,
Step 2: Determine the Actions (Loads) (EN 1991)
The primary out-of-plane load for a simple wall is wind.
-
Wind Load (w_k):
- Calculated according to EN 1991-1-4 (Actions on structures - Wind actions).
- This calculation is complex and depends on the building's location (wind zone), height, terrain category, and shape.
- The result is a characteristic wind pressure (
w_k) in kN/m².
-
Partial Safety Factor for Actions (γ_Q):
- This factor increases the variable action (wind) to its design value.
- For variable actions,
γ_Qis typically 1.5.
Step 3: Calculate the Design Action Effect (M_Ed)
This is the maximum bending moment the loads will cause in the wall. The formula depends on the wall's support conditions. We'll use the most common case: a wall simply supported at the top and bottom, under a uniform wind load.
-
Calculate the Design Wind Load (w_d):
w_d = w_k * γ_QExample: Ifw_k = 0.8 kN/m², thenw_d = 0.8 * 1.5 = 1.2 kN/m². -
Calculate the Design Bending Moment (M_Ed): The formula for a simply supported beam/wall under a uniform load is:
M_Ed = (w_d * h_ef²) / 8This is calculated per meter length of the wall.Example: For a 3.0 m high wall:
M_Ed = (1.2 kN/m² * (3.0 m)²) / 8 = 1.35 kNm/mThis means the design bending moment at the mid-height of the wall is 1.35 kNm per meter of wall length.
Step 4: Calculate the Design Resistance of the Wall (M_Rd)
This is the maximum bending moment the wall can resist before failing.
-
Calculate the Design Flexural Strength (f_xd): You must use the flexural strength value corresponding to the direction of bending. For a wall bending vertically, the failure plane is horizontal (parallel to the bed joints), so you use
f_xk1.f_xd = f_xk1 / γ_MExample: If
f_xk1 = 0.15 N/mm²(or 150 kN/m²) andγ_M = 2.5:f_xd = 150 kN/m² / 2.5 = 60 kN/m² -
Calculate the Section Modulus (Z): The section modulus is a geometric property of the wall's cross-section. For a solid rectangular section, calculated per meter length:
Z = (b * t²) / 6Since we work per meter length,b = 1.0 m.Z = (1.0 * t²) / 6Example: For a wall with thickness
t = 0.5 m:Z = (1.0 * (0.5 m)²) / 6 = 0.0417 m³ -
Calculate the Design Moment of Resistance (M_Rd):
M_Rd = f_xd * ZExample:
M_Rd = 60 kN/m² * 0.0417 m³ = 2.5 kNm/mThis means the wall can resist a bending moment of 2.5 kNm per meter of wall length.
Step 5: The Verification (The Final Check)
Now, you compare the action effect with the resistance.
Is M_Ed ≤ M_Rd?
-
From our example:
M_Ed = 1.35 kNm/m(the moment caused by the wind)M_Rd = 2.50 kNm/m(the moment the wall can resist)
-
Conclusion:
1.35 ≤ 2.50-> The condition is satisfied.
The wall is considered SAFE against out-of-plane bending failure under the specified wind load. If
M_Edwere greater thanM_Rd, the wall would be in a FAILSTATE and would need to be made thicker, have its materials improved, or be provided with additional support.Special Case: Freestanding Wall (Overturning)
For a freestanding wall (like a garden wall, cantilevered from the base), you must also check for overturning.
- Overturning Moment (M_ov,d): The moment caused by the total wind force acting at mid-height.
M_ov,d = (w_d * h) * (h / 2) - Restoring Moment (M_res,d): The moment caused by the wall's self-weight. A favourable partial safety factor
γ_G,fav(often 0.9) is used.M_res,d = (Self-Weight * γ_G,fav) * (t / 2) - Verification:
M_ov,d ≤ M_res,d
Disclaimer: This is a simplified explanation of the process. A full Eurocode design requires careful consideration of all relevant clauses, the correct use of the National Annex for your country, and an understanding of the specific conditions of the project. For any real-world application, you must consult a qualified structural engineer.