Calculating the "failstate" (which generally refers to the ultimate limit state of failure) of a stone wall in its own direction, according to European norms, primarily involves assessing its resistance to vertical compressive loads and stability against buckling due to its slenderness.
The relevant European Standard for the design of masonry structures is EN 1996 (Eurocode 6): Design of Masonry Structures. Specifically, EN 1996-1-1 deals with general rules for reinforced and unreinforced masonry.
For a traditional "stonewall" (implying unreinforced masonry), the primary failure modes in its own direction are:
- Crushing (Compressive Failure): The masonry material itself (stones, mortar, or the composite wall) reaches its ultimate compressive strength.
- Buckling (Slenderness Failure): The wall becomes unstable under vertical load due to its height-to-thickness ratio, causing it to deflect laterally and collapse even if the material's compressive strength hasn't been fully reached.
Here's a step-by-step guide to how this calculation is approached according to EN 1996-1-1:
Fundamental Principle:
The design vertical load (N_Ed) must be less than or equal to the design vertical resistance (N_Rd) of the wall.
N_Ed ≤ N_Rd
Step-by-Step Calculation Process (Simplified Overview)
1. Determine Material Properties:
- Characteristic Compressive Strength of Masonry (f_k): This is the most crucial material property. It depends on:
- The characteristic compressive strength of the masonry units (stones) –
f_b.
- The characteristic compressive strength of the mortar –
f_m.
- The configuration of the masonry (e.g., solid, hollow, dressed stone, rubble).
f_k is derived from tables in EN 1996-1-1 (e.g., Table 3.1) based on f_b, f_m, and the group/type of masonry unit. For irregular stone walls (rubble masonry), determining a reliable f_k can be challenging and often requires engineering judgment or specific testing.
- Modulus of Elasticity (E): While less critical for pure crushing, it's essential for buckling analysis. For masonry,
E is often taken as 1000 * f_k (for normal weight masonry) or determined through specific tests.
- Creep Coefficient (φ): For long-term loads, creep can increase eccentricity over time.
2. Determine Geometric Properties:
- Height (h): Actual height of the wall.
- Thickness (t): Actual thickness of the wall.
- Effective Height (h_ef): This accounts for the restraint provided by floors, roofs, or intersecting walls. EN 1996-1-1 provides factors (e.g., Figure 5.1 and Clause 5.5.1) to multiply the actual height based on support conditions (e.g., 0.75h for fixed-pinned, 1.0h for pinned-pinned).
- Effective Thickness (t_ef): For a solid wall, this is generally the actual thickness. For cavity walls or walls with recesses, it needs adjustment.
- Slenderness Ratio (λ): Calculated as
λ = h_ef / t_ef. This ratio is key for buckling assessment.
3. Determine Design Loads (N_Ed):
- Identify all vertical characteristic loads acting on the wall:
- Permanent Loads (G_k): Self-weight of the wall, weight of floors, roofs, finishes, etc.
- Variable Loads (Q_k): Live loads from occupancy, snow loads, wind loads (if they induce vertical components).
- Apply partial factors for loads (γ_G, γ_Q) according to EN 1990 (Eurocode 0): Basis of Structural Design.
γ_G typically 1.35 for permanent loads.
γ_Q typically 1.50 for variable loads.
- N_Ed = Σ (γ_G * G_k) + Σ (γ_Q * Q_k) (This is a simplified combination. More complex combinations considering different variable loads might be required).
4. Account for Eccentricity of Loading (e):
- Vertical loads are rarely perfectly axial. Eccentricity causes bending moments, reducing the wall's compressive capacity.
- Initial Eccentricity (e_init): Due to construction imperfections or manufacturing tolerances.
- Additional Eccentricity (e_add): Due to the actual placement of floor beams, roof trusses, or load spread.
- Second-Order Eccentricity: From the buckling deformation of the wall itself (magnified by creep effects for long-term loads).
- Total eccentricity
e = e_init + e_add + e_secondary. EN 1996-1-1 provides guidance on calculating these (e.g., Clause 6.1.2).
5. Calculate Design Vertical Resistance (N_Rd):
- The design resistance is given by the formula:
N_Rd = Φ * t_ef * l * f_k / γ_M
Where:
Φ (Phi) is the reduction factor for slenderness and eccentricity. This is the most complex part of the calculation. It accounts for the combined effect of the wall's slenderness ratio (λ) and the eccentricity of the applied load (e / t_ef). Φ values are typically found in tables or charts in EN 1996-1-1 (e.g., Table 6.1 or Figure 6.1) based on the specific analysis method chosen (simplified, detailed).
t_ef is the effective thickness.
l is the length of the wall being considered (usually taken as 1 meter for design purposes unless analyzing a specific pier).
f_k is the characteristic compressive strength of masonry.
γ_M is the partial factor for resistance of masonry. This accounts for uncertainties in material properties and manufacturing control. Its value depends on the category of manufacturing control (e.g., Category I: 2.7, Category II: 3.0 for general purpose units in EN 1996-1-1, Table 2.1). For rubble stone walls, a higher γ_M might be prudent or specified by national annexes.
6. Check the Ultimate Limit State (ULS):
- Compare
N_Ed with N_Rd.
- If
N_Ed ≤ N_Rd, the wall is considered safe against compressive and buckling failure in its own direction.
- If
N_Ed > N_Rd, the wall is deemed to be in a "failstate" (or predicted to fail) under the design loads.
Important Considerations for Stone Walls:
- Rubble Stone Walls: These are highly variable. Determining
f_k can be very challenging without specific testing of wall samples. Engineering judgment and conservative assumptions are often necessary. γ_M might need to be increased further to account for variability in workmanship and material quality.
- Workmanship and Quality Control: The quality of the construction, especially mortar joints and the interlocking of stones, significantly impacts
f_k and the overall stability. EN 1996-1-1 pre-supposes a certain level of manufacturing control and workmanship.
- Moisture Content: Stone walls can be affected by moisture, especially if not properly drained or protected, which can degrade mortar or cause frost damage, impacting long-term strength.
- Existing Walls: For assessing existing stone walls, material properties might need to be determined by non-destructive testing, core samples, or historical data. Deterioration over time must be factored in.
- Other Failure Modes: While the question specifies "in its own direction," remember that walls can also fail due to:
- Shear failure: Under lateral loads (e.g., seismic, wind acting parallel to the wall).
- Out-of-plane bending: Under lateral loads perpendicular to the wall.
- Foundation failure: The ground beneath the wall is insufficient.
- Differential Settlement: Uneven movement of the foundation.
Conclusion
Calculating the failstate of a stone wall in its own direction according to European norms is a complex engineering task that requires a thorough understanding of EN 1996-1-1, specific material properties, load combinations, and careful consideration of geometry and support conditions. Given the variability of traditional stone walls, it often requires significant engineering experience and judgment.
It is strongly advised that such calculations be performed by a qualified structural engineer.