To calculate the increase in effective rainfall due to urbanization, we'll follow these steps, utilizing the Soil Conservation Service (SCS) Curve Number (CN) method for estimating runoff. The SCS-CN method relates rainfall to runoff through the Curve Number, which is a function of soil type, land use, and hydrologic condition.
Given Data:
- Initial Rainfall: 5 inches
- Watershed Area: 1000 acres
- Soil Type: B
- Initial Land Use & Condition: Open land in fair condition
- Post-Urbanization Land Use:
- 30% Industrial district
- 70% Residential (1/8 acres, 65% impervious)
Step 1: Determine Initial Curve Number (CN)
- Soil Type: B
- Initial Land Use & Condition: Open land in fair condition
| Soil Type | Open Space (Fair) | Industrial | Residential (1/8 acre, 65% impervious) |
|---|
| B | 61 | 77 (Assumed, as specific CN for Industrial not given) | 85 (Assumed, based on high impervious cover) |
Initial CN (Open Land, Fair, Soil B): 61
Step 2: Calculate Post-Urbanization Composite Curve Number (CN)
Given the lack of precise CN values for "Industrial" and the specific residential type in the table, we'll use the assumed values from Step 1. Normally, one would consult more detailed SCS-CN tables or guidelines for these specific land uses.
- 30% Industrial: CN = 77 (Assumed)
- 70% Residential (1/8 acres, 65% impervious): CN = 85 (Assumed)
Composite CN Calculation:
[ \text{Composite CN} = \frac{(A_1 \times CN_1) + (A_2 \times CN_2)}{A_1 + A_2} ]
Where:
- (A_1 = 0.3 \times 1000 = 300) acres (Industrial),
- (A_2 = 0.7 \times 1000 = 700) acres (Residential),
- (CN_1 = 77),
- (CN_2 = 85).
[ \text{Composite CN} = \frac{(300 \times 77) + (700 \times 85)}{300 + 700} ]
[ \text{Composite CN} = \frac{23100 + 59500}{1000} ]
[ \text{Composite CN} = \frac{82600}{1000} ]
[ \text{Composite CN} = 82.6 ]
Step 3: Calculate Initial and Post-Urbanization Runoff using SCS-CN Method
The SCS-CN method uses the following formula to estimate runoff (Q):
[ Q = \frac{(P - I_a)^2}{P - I_a + S} ]
Where:
- (Q) = Runoff (inches),
- (P) = Rainfall (inches),
- (I_a) = Initial Abstraction (approximated as (0.2S)),
- (S) = Potential Maximum Retention (inches), calculated as (S = \frac{1000}{CN} - 10).
Initial Conditions (CN=61):
- (S = \frac{1000}{61} - 10 \approx 6.39) inches
- (I_a \approx 0.2 \times 6.39 \approx 1.28) inches
Post-Urbanization Conditions (CN=82.6):
- (S = \frac{1000}{82.6} - 10 \approx 1.83) inches
- (I_a \approx 0.2 \times 1.83 \approx 0.366) inches
Calculating Runoff for 5 Inches Rainfall:
Initial Runoff (CN=61)
[ Q_{Initial} = \frac{(5 - 1.28)^2}{5 - 1.28 + 6.39} \approx \frac{14.59}{10.11} \approx 1.44 \text{ inches} ]
Post-Urbanization Runoff (CN=82.6)
[ Q_{Post} = \frac{(5 - 0.366)^2}{5 - 0.366 + 1.83} \approx \frac{21.33}{6.464} \approx 3.298 \text{ inches} ]
Step 4: Calculate Increase in Effective Rainfall
Effective rainfall is essentially the rainfall that contributes to runoff (i.e., the runoff itself). The increase in effective rainfall due to urbanization is the difference in runoff before and after urbanization.
[ \text{Increase in Effective Rainfall} = Q_{Post} - Q_{Initial} ]
[ \text{Increase in Effective Rainfall} \approx 3.298 - 1.44 ]
[ \text{Increase in Effective Rainfall} \approx 1.858 \text{ inches} ]
Note: The calculated increase in effective rainfall (~1.858 inches) does not exactly match the provided answer (1.498 inches). This discrepancy could arise from several factors:
- Assumed CN Values: For industrial and residential areas, as exact values weren't specified. Using standardized or locally validated CN values can reduce this discrepancy.
- Rounding Errors: Throughout the calculations. Minimizing rounding during intermediate steps can help align the results more closely.
- Methodological Simplifications: The SCS-CN method, while robust, simplifies complex hydrologic processes. More advanced models or site-specific calibrations might yield results closer to the expected answer.
- Potential Differences in Calculation Approach: The given answer of 1.498 inches might result from slightly different assumptions or rounding during calculations. Revisiting each step with precise values or alternative assumptions could help reconcile this difference.
For educational purposes, this walkthrough should provide a clear methodological pathway. However, for precise engineering or environmental assessments, consulting detailed SCS-CN tables, local hydrologic data, and potentially more advanced hydrologic models is recommended. Additionally, validating calculations against known results or using sensitivity analyses can help ensure accuracy in real-world applications.