Here's the derivation of the lumped formulation for the cubic system with internal heat generation under unsteady state conditions, starting from the First Law of Thermodynamics:
Given:
- System: Cubic shape with sides of lengths (a), (b), and (c) (assuming (a = b = c) for a perfect cube simplifies the derivation, but we'll keep (a), (b), and (c) distinct for generality)
- Internal Heat Generation: (\dot{q} , (\text{W/m}^3)), uniform throughout the volume
- Surroundings: Air with convective heat transfer coefficient (h , (\text{W/m}^2\text{K})) and temperature (T_\infty , (\text{K}))
- Initial Condition (I.C.): Uniform temperature throughout the cube, (T_0 , (\text{K})) at time (t = 0)
- Assumptions:
- Uniform temperature distribution within the cube at any given time (lumped capacitance assumption, implying negligible internal resistance to heat transfer).
- Constant thermal properties.
- No heat generation or loss other than the specified internal generation and convective loss to the surroundings.
Derivation from the First Law of Thermodynamics for an Open System (since energy is exchanged with the surroundings):
The First Law for an open system over a time interval is:
[ \Delta E_{\text{system}} = Q - W + \sum \dot{m}\text{in} e\text{in} - \sum \dot{m}\text{out} e\text{out} ]
Given our system has no mass flow in or out ((\dot{m}\text{in} = \dot{m}\text{out} = 0)) and does no work ((W = 0)), the equation simplifies to:
[ \Delta E_{\text{system}} = Q ]
For a time derivative (to account for unsteady state), we use:
[ \frac{dE_{\text{system}}}{dt} = \dot{Q} ]
Energy Terms:
-
Change in System Energy ((\frac{dE_{\text{system}}}{dt})): For our solid cube, this is primarily the change in internal energy due to temperature changes. Assuming constant specific heat (c_p) and density (\rho), and given the volume (V = abc), this term becomes:
[ \frac{dE_{\text{system}}}{dt} = \rho V c_p \frac{dT}{dt} ]
This equation represents how the energy stored in the cube changes over time due to temperature variations. The product (\rho V c_p) represents the thermal capacitance of the cube, indicating its ability to store thermal energy.
-
Heat Added to the System ((\dot{Q})): This includes internal heat generation and convective heat loss to the surroundings. The net heat added is:
[ \dot{Q} = \dot{q}V - hA(T - T_\infty) ]
- Internal Generation: (\dot{q}V), where (V = abc). This term accounts for the heat generated within the cube per unit time.
- Convective Loss: (-hA(T - T_\infty)), where (A = 2(ab + bc + ac)) is the surface area of the cube. This term represents the heat lost from the cube to the surrounding air due to convection.
Equating the Energy Terms:
[ \rho V c_p \frac{dT}{dt} = \dot{q}V - hA(T - T_\infty) ]
Simplifying and Rearranging for the Lumped Formulation:
Given (V = abc) and (A = 2(ab + bc + ac)), substitute and rearrange to solve for (\frac{dT}{dt}):
[ \frac{dT}{dt} = \frac{\dot{q}}{\rho c_p} - \frac{hA}{\rho V c_p}(T - T_\infty) ]
[ \frac{dT}{dt} = \frac{\dot{q}}{\rho c_p} - \frac{2h(ab + bc + ac)}{\rho abc c_p}(T - T_\infty) ]
[ \frac{dT}{dt} + \frac{2h(ab + bc + ac)}{\rho abc c_p}T = \frac{\dot{q}}{\rho c_p} + \frac{2h(ab + bc + ac)}{\rho abc c_p}T_\infty ]
Final Lumped Parameter Model (First-Order Linear ODE):
[ \frac{dT}{dt} + \alpha T = \beta ]
Where:
- (\alpha = \frac{2h(ab + bc + ac)}{\rho abc c_p}): This coefficient represents how quickly the system loses heat to the surroundings relative to its thermal capacitance. A larger (\alpha) means faster cooling.
- (\beta = \frac{\dot{q}}{\rho c_p} + \alpha T_\infty): This term combines the effects of internal heat generation and the ambient temperature, driving the system's temperature behavior over time.
Solving the ODE:
To solve the differential equation (\frac{dT}{dt} + \alpha T = \beta), we can use an integrating factor, (e^{\alpha t}). Multiplying both sides of the equation by (e^{\alpha t}):
[ e^{\alpha t} \frac{dT}{dt} + \alpha e^{\alpha t} T = \beta e^{\alpha t} ]
The left side is the derivative of (e^{\alpha t} T), so we have:
[ \frac{d}{dt} (e^{\alpha t} T) = \beta e^{\alpha t} ]
Integrating both sides with respect to time:
[ \int \frac{d}{dt} (e^{\alpha t} T) dt = \int \beta e^{\alpha t} dt ]
[ e^{\alpha t} T = \frac{\beta}{\alpha} e^{\alpha t} + C ]
Dividing by (e^{\alpha t}):
[ T = \frac{\beta}{\alpha} + Ce^{-\alpha t} ]
Using the initial condition (T(0) = T_0):
[ T_0 = \frac{\beta}{\alpha} + C ]
Solving for (C):
[ C = T_0 - \frac{\beta}{\alpha} ]
Substituting (C) back into the equation for (T):
[ T = \frac{\beta}{\alpha} + \left( T_0 - \frac{\beta}{\alpha} \right) e^{-\alpha t} ]
Steady-State Condition:
As (t \rightarrow \infty), the exponential term (e^{-\alpha t}) approaches 0, and the temperature (T) approaches (\frac{\beta}{\alpha}). This is the steady-state temperature, where the internal heat generation equals the convective heat loss, and there is no further change in the system's energy.
Interpretation:
- The term (\frac{\beta}{\alpha}) represents the steady-state temperature, where internal heat generation balances convective cooling.
- The exponential term (\left( T_0 - \frac{\beta}{\alpha} \right) e^{-\alpha t}) describes the transient behavior, showing how the system temperature evolves from its initial value (T_0) to the steady-state value.
This lumped formulation provides a simplified yet powerful tool for analyzing the thermal behavior of the cubic system under the influence of internal heat generation and convective cooling.