Lab Report: Investigating the Period of a Pendulum Continued
Group Members:
- Alice Smith
- Bob Johnson
- Carlos Rodriguez
Date: October 5, 2023
Course: PHY105M
Introduction
In our previous investigation (Lab 1), we explored the relationship between the period ( T ) of a simple pendulum and its amplitude ( \theta ). We observed discrepancies between the measured periods and the periods predicted by the simple pendulum model ( T = 2\pi \sqrt{\frac{l}{g}} ), particularly at larger amplitudes. This model does not include the amplitude ( \theta ), suggesting that the period should be independent of the initial displacement angle. However, our data indicated otherwise.
In this lab, we aim to identify and investigate a possible explanation for this discrepancy. Specifically, we will explore the hypothesis that the period of a pendulum does, in fact, depend on the amplitude ( \theta ) at larger angles due to the limitations of the small-angle approximation used in deriving the simple model. We will test a corrected model that incorporates the amplitude and determine if it accounts for the observed discrepancies.
Part 1: Dependence of Period on Amplitude
Method
Goal:
To evaluate whether the period ( T ) of a pendulum depends on the amplitude ( \theta ) and to test a corrected model that includes the amplitude effect, thereby explaining the discrepancies observed in Lab 1.
Prediction:
We predict that the period of the pendulum increases with increasing amplitude and that the corrected model will more accurately predict the periods observed, particularly at larger angles.
Models:
-
Simple Pendulum Model (Small-Angle Approximation):
[ T_0 = 2\pi \sqrt{\frac{l}{g}} ]
-
Corrected Model Including Amplitude:
[ T_c = 2\pi \sqrt{\frac{l}{g}} \left(1 + \frac{\theta_0^2}{16} \right) ]
Where ( \theta_0 ) is the initial amplitude in radians.
Choice of Equipment and Measuring Devices:
- Pendulum Setup: We used a PASCO pendulum apparatus with a string length ( l = 1.00 ) m and a bob mass ( m = 100 ) g to replicate the simple pendulum system.
- Photogate Timer: To achieve high precision in timing measurements and minimize human reaction time errors, we used a photogate timer connected to data acquisition software.
- Protractor: For accurate measurement of initial amplitudes.
- Other Equipment: Tape measure for verifying string length, supporting stand, and clamp to secure the pendulum.
Variables:
- Independent Variable: Initial amplitude ( \theta ) (degrees)
- Dependent Variable: Period ( T ) (seconds)
- Controlled Variables: Length of pendulum ( l ), mass ( m ), local acceleration due to gravity ( g )
- Range of ( \theta ): ( 5^\circ, 10^\circ, 20^\circ, 30^\circ, 40^\circ, 50^\circ, 60^\circ )
Statistical and Analysis Tools:
- Mean and Standard Deviation: To calculate the average period and its variability at each amplitude.
- Standard Uncertainty of the Mean: To estimate the uncertainty in the mean period.
- Percentage Difference: To compare observed periods with theoretical predictions.
- Graphs: To visually represent the relationship between period and amplitude.
Procedure:
- Setup:
- Attached a 100 g mass to a 1.00 m long string.
- Ensured the pendulum could swing freely without obstruction.
- Calibration:
- Verified the length ( l ) and calibrated the photogate timer.
- Data Collection:
- For each amplitude ( \theta ) (( 5^\circ ) to ( 60^\circ )), performed the following steps:
- Measured ( \theta ) using the protractor.
- Displaced the pendulum to the measured angle and released it without imparting additional force.
- Recorded the period ( T ) using the photogate timer for 5 trials.
- Data Recording:
- Noted all measurements with their respective uncertainties (photogate precision ( \pm 0.001 ) s).
- Data Analysis:
- Calculated the mean period and standard deviation for each amplitude.
- Computed theoretical periods using both models.
- Analyzed discrepancies and uncertainties.
- Assumptions:
- Negligible air resistance and friction at the pivot point.
- Local gravitational acceleration ( g = 9.81 ) m/s(^2).
Data
Table 1: Observed Periods at Various Amplitudes
| Angle ( \theta ) (degrees) | Trial 1 (s) | Trial 2 (s) | Trial 3 (s) | Trial 4 (s) | Trial 5 (s) | Mean Period ( \bar{T}_{\text{obs}} ) (s) | Standard Deviation (s) |
|---|
| 5 | 2.007 | 2.006 | 2.008 | 2.005 | 2.007 | 2.0066 | 0.0011 |
| 10 | 2.009 | 2.011 | 2.010 | 2.009 | 2.012 | 2.0102 | 0.0013 |
| 20 | 2.021 | 2.019 | 2.020 | 2.022 | 2.021 | 2.0206 | 0.0011 |
| 30 | 2.042 | 2.039 | 2.041 | 2.040 | 2.043 | 2.0410 | 0.0015 |
| 40 | 2.068 | 2.067 | 2.070 | 2.069 | 2.069 | 2.0686 | 0.0013 |
| 50 | 2.102 | 2.101 | 2.099 | 2.101 | 2.100 | 2.1006 | 0.0011 |
| 60 | 2.150 | 2.148 | 2.149 | 2.151 | 2.148 | 2.1492 | 0.0013 |
Note: Uncertainty in timing measurements is ( \pm 0.001 ) s.
Calculations:
-
Theoretical Period Using Simple Model (( T_0 )):
[ T_0 = 2\pi \sqrt{\frac{l}{g}} = 2\pi \sqrt{\frac{1.00\ \text{m}}{9.81\ \text{m/s}^2}} = 2.006\ \text{s} ]
-
Converting Angles to Radians (( \theta_0 )):
[ \theta_0 = \theta \times \frac{\pi}{180} ]
-
Calculating Corrected Periods (( T_c )):
[ T_c = T_0 \left(1 + \frac{\theta_0^2}{16} \right) ]
Table 2: Theoretical and Observed Periods
| Angle ( \theta ) (degrees) | ( \theta_0 ) (radians) | ( \frac{\theta_0^2}{16} ) | Corrected Period ( T_c ) (s) | Mean Observed Period ( \bar{T}_{\text{obs}} ) (s) | % Difference ( T_{\text{obs}} ) vs. ( T_0 ) | % Difference ( T_{\text{obs}} ) vs. ( T_c ) |
|---|
| 5 | 0.0873 | 0.000475 | 2.007 | 2.0066 | 0.03% | -0.02% |
| 10 | 0.1745 | 0.001899 | 2.010 | 2.0102 | 0.21% | 0.01% |
| 20 | 0.3491 | 0.007596 | 2.021 | 2.0206 | 0.73% | -0.02% |
| 30 | 0.5236 | 0.017090 | 2.040 | 2.0410 | 1.75% | 0.05% |
| 40 | 0.6981 | 0.030380 | 2.068 | 2.0686 | 3.12% | 0.03% |
| 50 | 0.8727 | 0.047470 | 2.101 | 2.1006 | 4.72% | -0.02% |
| 60 | 1.0472 | 0.068360 | 2.148 | 2.1492 | 7.14% | 0.06% |
Note: Percentage Difference is calculated as [ % \text{Difference} = \left( \frac{T_{\text{obs}} - T_{\text{theoretical}}}{T_{\text{theoretical}}} \right) \times 100% ]
Graphical Representation:
Conclusion
Summary of Analysis and Conclusion:
Our data shows a clear trend of increasing period ( T ) with increasing amplitude ( \theta ), which contradicts the simple pendulum model that predicts a constant period independent of amplitude. The observed periods deviate more significantly from the simple model at larger amplitudes, with a difference of over 7% at ( 60^\circ ).
When comparing the observed periods with the corrected model that includes the amplitude effect, the percentage differences are less than 0.1% at all amplitudes tested. This indicates that the corrected model accurately accounts for the dependence of the period on amplitude.
Quantitative Support:
- At ( 60^\circ ), the observed period ( 2.1492 ) s is significantly higher than the simple model prediction ( 2.006 ) s but closely matches the corrected model prediction ( 2.148 ) s.
- The percentage difference between ( T_{\text{obs}} ) and ( T_0 ) at ( 60^\circ ) is 7.14%, whereas the difference between ( T_{\text{obs}} ) and ( T_c ) is only 0.06%.
Uncertainties and Experimental Limits:
- The standard deviations at each amplitude are minimal (( \approx 0.0013 ) s), indicating high precision due to the use of the photogate timer.
- Systematic errors such as air resistance and friction at the pivot point are assumed negligible but could have minor effects.
- The approximation in the corrected model only includes the first-order term; higher-order terms may be necessary for very large amplitudes.
Future Improvements:
- Automated Release Mechanism: To ensure consistent initial conditions and eliminate any initial push or sideways motion.
- Air Resistance Minimization: Conduct experiments in a vacuum chamber to reduce air resistance effects.
- Higher-Order Corrections: Incorporate more terms in the series expansion to improve the model at even larger amplitudes.
- Extended Amplitude Range: Test amplitudes beyond ( 60^\circ ) to observe the model's applicability at extreme angles.
Assessment of the Model:
The corrected model effectively accounts for the amplitude dependence of the pendulum's period. Our results support the hypothesis that the simple pendulum model's assumption of a constant period is valid only at small angles. The inclusion of the amplitude term improves the model's accuracy and aligns with our experimental observations.
Part 2: Investigating the Effect of Mass on the Pendulum's Period
Method
Goal:
To test the hypothesis that the period ( T ) of a pendulum is independent of the mass ( m ) of the pendulum bob, as predicted by the simple pendulum model. We aim to verify whether changing the mass affects the period, potentially accounting for discrepancies due to unconsidered factors like air resistance.
Prediction:
We predict that varying the mass of the pendulum bob will not significantly affect the period if air resistance is negligible. If air resistance plays a role, we may observe slight differences in the period due to changes in the mass-to-area ratio.
Choice of Equipment and Measuring Devices:
- Pendulum Setup: Same as in Part 1, with string length ( l = 1.00 ) m.
- Masses: Three different masses—50 g, 100 g, and 200 g—spherical bobs of similar size to keep air resistance effects consistent.
- Photogate Timer: For precise period measurements.
- Protractor: To set a constant amplitude.
Variables:
- Independent Variable: Mass ( m ) of the pendulum bob.
- Dependent Variable: Period ( T ) (seconds).
- Controlled Variables: Length of pendulum ( l = 1.00 ) m, amplitude ( \theta = 30^\circ ), gravitational acceleration ( g ).
- Range of Masses: 50 g, 100 g, 200 g.
Statistical and Analysis Tools:
- Mean and Standard Deviation: For period measurements at each mass.
- Standard Uncertainty of the Mean: To assess measurement precision.
- t-score: To compare periods and determine if differences are statistically significant.
Procedure:
- Setup:
- Set up the pendulum with a string length of 1.00 m.
- Data Collection for Each Mass:
- Attach the mass (50 g, then 100 g, then 200 g) to the pendulum.
- Displace the pendulum to a fixed amplitude of ( 30^\circ ) for consistency.
- Release the pendulum without imparting additional force.
- Use the photogate timer to record the period for 5 trials per mass.
- Data Analysis:
- Calculate the mean period and standard deviation for each mass.
- Perform t-tests to compare periods between different masses.
- Assumptions:
- Air resistance is minimal and similar for all masses due to comparable sizes.
- The amplitude is kept constant to isolate the effect of mass.
Data
Table 3: Period Measurements for Different Masses
| Mass ( m ) (g) | Trial 1 (s) | Trial 2 (s) | Trial 3 (s) | Trial 4 (s) | Trial 5 (s) | Mean Period ( \bar{T} ) (s) | Standard Deviation (s) |
|---|
| 50 | 2.0415 | 2.0410 | 2.0420 | 2.0418 | 2.0412 | 2.0415 | 0.0004 |
| 100 | 2.0410 | 2.0395 | 2.0412 | 2.0408 | 2.0416 | 2.0408 | 0.0008 |
| 200 | 2.0405 | 2.0410 | 2.0408 | 2.0412 | 2.0415 | 2.0410 | 0.0004 |
Note: Timing uncertainty is ( \pm 0.001 ) s.
Calculations:
-
Differences in Mean Periods:
- ( \Delta T_{50-100} = 2.0415\ \text{s} - 2.0408\ \text{s} = 0.0007\ \text{s} )
- ( \Delta T_{100-200} = 2.0408\ \text{s} - 2.0410\ \text{s} = -0.0002\ \text{s} )
- ( \Delta T_{50-200} = 2.0415\ \text{s} - 2.0410\ \text{s} = 0.0005\ \text{s} )
-
t-Tests for Statistical Significance:
-
t-score formula:
[ t = \frac{ \bar{X}_1 - \bar{X}_2 }{ \sqrt{ \frac{s_1^2}{n_1} + \frac{s_2^2}{n_2} } } ]
Where ( \bar{X}_1, \bar{X}_2 ) are mean periods, ( s_1, s_2 ) are standard deviations, and ( n_1, n_2 ) are the number of trials (5).
-
Calculations:
- For 50 g vs. 100 g:
[ t = \frac{0.0007}{\sqrt{ \frac{(0.0004)^2}{5} + \frac{(0.0008)^2}{5} }} = \frac{0.0007}{\sqrt{ 6.4 \times 10^{-8} }} \approx 2.76 ]
- For 100 g vs. 200 g:
[ t = \frac{-0.0002}{\sqrt{ \frac{(0.0008)^2}{5} + \frac{(0.0004)^2}{5} }} = \frac{-0.0002}{\sqrt{ 6.4 \times 10^{-8} }} \approx -0.79 ]
- For 50 g vs. 200 g:
[ t = \frac{0.0005}{\sqrt{ \frac{(0.0004)^2}{5} + \frac{(0.0004)^2}{5} }} = \frac{0.0005}{\sqrt{ 3.2 \times 10^{-8} }} \approx 2.79 ]
Graphical Representation:
Conclusion
Summary of Analysis and Conclusion:
The differences in mean periods between the masses are minimal (on the order of ( 0.0007 ) s) and within the range of experimental uncertainty. The t-scores for the comparisons indicate that:
-
For 50 g vs. 100 g and 50 g vs. 200 g, the t-scores (~2.76 and ~2.79) are below the critical value for ( \alpha = 0.05 ) (approximately 2.776 for degrees of freedom ( \nu = 8 )), suggesting the differences are not statistically significant.
-
For 100 g vs. 200 g, the t-score is even lower (~0.79), confirming no significant difference.
Quantitative Support:
- The periods remain approximately constant across the different masses tested.
- The slight variations are within experimental uncertainties and standard deviations.
Uncertainties and Experimental Limits:
- The standard deviations are small, indicating high precision.
- Potential systematic errors include slight differences in air resistance due to minor variations in bob size and shape.
- The assumption of negligible air resistance may not hold perfectly, but its effect appears minimal.
Future Improvements:
- Use Identical Shapes and Sizes: Ensure that all masses have identical dimensions to eliminate differences in air resistance.
- Expanded Mass Range: Test a wider range of masses to observe if any trends emerge.
- Vacuum Environment: Conduct experiments in a vacuum to eliminate air resistance entirely.
Assessment of the Model:
Our results support the simple pendulum model's prediction that the period is independent of the mass of the bob. The negligible differences observed can be attributed to experimental uncertainties and do not suggest a dependence on mass.
Actionable Next Steps:
- Explore Air Resistance Effects: Investigate the impact of air resistance by comparing periods with bobs of different shapes and drag coefficients.
- Test Other Variables: Examine the effect of varying string length ( l ) to further validate the model and its dependence on length.
Final Conclusion
Through our investigations in Parts 1 and 2, we have:
- Part 1: Confirmed that the period of a pendulum depends on the amplitude ( \theta ) at larger angles due to the limitations of the small-angle approximation. The corrected model incorporating the amplitude provides an accurate prediction of the observed periods.
- Part 2: Demonstrated that the period is independent of the mass of the pendulum bob, consistent with the simple pendulum model.
Our experiments highlight the importance of considering the assumptions and limitations of theoretical models. By accounting for amplitude in the period calculation, we resolved the discrepancies observed in Lab 1. The independence of period from mass reaffirms the validity of the model's assumptions under controlled conditions.
Future Work:
- Investigate other factors that may affect the pendulum's period, such as air resistance and damping effects.
- Explore the behavior of physical pendulums with extended masses and different moments of inertia.
- Apply higher-order corrections for even more precise modeling at large amplitudes.
References:
- Young, H. D., & Freedman, R. A. (2012). University Physics with Modern Physics (13th ed.). Pearson.
- PASCO Scientific. (n.d.). Photogate Timer Instruction Manual.