please bring the whole data of the guarantee figures in the text, into one table…
- User
please bring the whole data of the guarantee figures in the text, into one table including the related plant and the conditions of that guaranteed figures. please specify and separate the feeds for all of plants alongs with their feeds and guaranteed figures, also for utilities and products in three categories: "EHA plant:
- FEED & PRODUCT GUARANTEES 1.1. FEED The PROCESS UNIT shall consume not more than 58 TONS per OPERATING DAY OF Acrylic Acid with the specification set forth in Appendix 2. 1.2. PRODUCT The PROCESS UNIT shall produce not less than 134 Tons, average per OPERATING DAY of with 2-Ethylhexyl Acrylate the specification set forth in Appendix 2. UTILITY CONSUMPTION GUARANTEES 2.1. ELECTRICITY The PROCESS UNIT(S) shall consume not more than 40 KWH per Ton of the 2-Ethylhexyl Acrylate PRODUCT. 2.2. STEAM The PROCESS UNIT(S) shall consume not more than 1.06 Tons high PRESSURE STEAM (2.0MPaG pressure and 214.8℃ temperature) per Ton of the 2-Ethylhexyl Acrylate PRODUCT. The PROCESS UNIT(S) shall consume not more than 1.24 Tons low PRESSURE STEAM (0.25MPaG pressure and 138℃ temperature) per Ton of the 2-Ethylhexyl Acrylate PRODUCT. 2.3. CIRCULATING COOLING WATER The PROCESS UNIT(S) shall consume not more than 21.5 m3 of circulating cooling water per Ton of the 2-Ethylhexyl Acrylate PRODUCT. Cooling water incoming temperature to PROCESS UNIT(S) 34°C cooling water outgoing temperature from PROCESS UNIT(S) 44 °C. 2.4. CHILLED WATER The PROCESS UNIT(S) shall consume not more than 56.7 m3 of circulating cooling water per Ton of the 2-Ethylhexyl Acrylate PRODUCT. Chilled water incoming temperature to PROCESS UNIT(S) 5 °C chilled water outgoing temperature from PROCESS UNIT(S) 10 °C."
AA Plant: FEED & PRODUCT GUARANTEES 1.1. FEED The PROCESS UNIT shall consume not more than 192.8 TONS per OPERATING DAY OF Propylene with the specification set forth in Appendix 2. 1.2. PRODUCT The PROCESS UNIT shall produce not less than 266 Tons, average per OPERATING DAY of with Acrylic Acid the specification set forth in Appendix 2. UTILITY CONSUMPTION GUARANTEES 2.1. ELECTRICITY The PROCESS UNIT(S) shall consume not more than 262.5 KWH per Ton of the Acrylic Acid PRODUCT. 2.2. STEAM The PROCESS UNIT(S) shall consume not more than 281 Tons high PRESSURE STEAM (2.0MPaG pressure and 214.8℃ temperature) per Ton of the Acrylic Acid PRODUCT. 2.3. CIRCULATING COOLING WATER The PROCESS UNIT(S) shall consume not more than 470 m3 of circulating cooling water per Ton of the Acrylic Acid PRODUCT. Cooling water incoming temperature to PROCESS UNIT(S) 34°C cooling water outgoing temperature from PROCESS UNIT(S) 44 °C. 2.4. CHILLED WATER The PROCESS UNIT(S) shall consume not more than 24 m3 of circulating cooling water per Ton of the Acrylic Acid PRODUCT. Chilled water incoming temperature to PROCESS UNIT(S) 0 °C chilled water outgoing temperature from PROCESS UNIT(S) 5 °C.
BA plant: Acrylic Ester Plant when produce Butyl Acrylate FEED & PRODUCT GUARANTEES 1.1. FEED The PROCESS UNIT shall consume not more than 75.3 TONS per OPERATING DAY OF Acrylic Acid with the specification set forth in Appendix 2. 1.2. PRODUCT The PROCESS UNIT shall produce not less than 125.5 Tons, average per OPERATING DAY of with Butyl Acrylate the specification set forth in Appendix 2. UTILITY CONSUMPTION GUARANTEES 2.1. ELECTRICITY The PROCESS UNIT(S) shall consume not more than 58 KWH per Ton of the Butyl Acrylate PRODUCT. 2.2. STEAM The PROCESS UNIT(S) shall consume not more than 0.81 Tons high PRESSURE STEAM (2.0MPaG pressure and 214.8℃ temperature) per Ton of the Butyl Acrylate PRODUCT. The PROCESS UNIT(S) shall consume not more than 0.95 Tons low PRESSURE STEAM (0.25MPaG pressure and 138℃ temperature) per Ton of the Butyl Acrylate PRODUCT. 2.3. CIRCULATING COOLING WATER The PROCESS UNIT(S) shall consume not more than 57 m3 of circulating cooling water per Ton of the Butyl Acrylate PRODUCT. Cooling water incoming temperature to PROCESS UNIT(S) 34°C cooling water outgoing temperature from PROCESS UNIT(S) 44 °C. 2.4. CHILLED WATER The PROCESS UNIT(S) shall consume not more than 151 m3 of circulating cooling water per Ton of the Butyl Acrylate PRODUCT. Chilled water incoming temperature to PROCESS UNIT(S) 5 °C chilled water outgoing temperature from PROCESS UNIT(S) 10 °C.
Assistant
Other models, same or similar prompt
Responses were produced in different, uncontrolled contexts (system prompts, settings, prior turns). This is not a benchmark.