Explaining and contrasting H∞ vs. H2/LQG objectives
H∞ control minimizes the peak gain (infinity norm) of the transfer function from disturbance to output, ensuring worst-case disturbance attenuation and robust stability under model uncertainty via the small-gain theorem. In contrast, H2/LQG control minimizes the average energy (RMS) of the output assuming known noise statistics, yielding optimal performance for a given model but poor robustness to unmodeled dynamics. This fundamental worst-case versus average-case distinction underlies why H∞ control is preferred for robust control design.
One convenient way of formulating both problems is in terms of the induced gain from an exogenous input (w) to a performance output (z) of the closed–loop system.
If you fix a stabilising controller (K) and look at the closed‑loop transfer matrix (T_{zw}(s)), the two standard norms that people minimise are
-
the (H_2)–norm
[
|T_{zw}|2^2 = \frac{1}{2\pi}\int{-\infty}^{\infty}!!\operatorname{trace},T_{zw}^*(j\omega)T_{zw}(j\omega),\mathrm{d}\omega,
]
which, for white‑noise (w), is proportional to the steady–state mean square value of (z); and
-
the (H_\infty)–norm
[
|T_{zw}|\infty = \sup{\omega},\bar\sigma\bigl(T_{zw}(j\omega)\bigr),
]
the peak singular value of (T_{zw}) over all frequencies, i.e. the worst–case amplification of an (L_2)–bounded input.
The linear–quadratic–Gaussian problem leads to an (H_2) minimisation: one assumes a known plant model driven by Gaussian process and measurement noise with known covariances, and designs a Kalman filter and LQ regulator to minimise the expected value of a quadratic cost. The resulting controller has small rms error for the assumed statistics, but its performance and even stability can degrade rapidly if the plant or disturbance statistics are different from the model.
The (H_\infty) problem, in contrast, is a minimax problem: you seek a controller that makes the induced (L_2)-gain from (w) to (z) as small as possible. In game–theoretic terms, the disturbance is an adversary choosing the worst‑case frequency and direction. By making (|T_{zw}|\infty) less than a prescribed (\gamma), you enforce a bound on the peak closed‑loop gain. When model uncertainty is described as an additive or multiplicative perturbation (\Delta) with (|\Delta|\infty\leq 1), the small–gain theorem gives a simple robust–stability condition (|\Delta T|\infty<1). Designing (T) to have a small (H\infty) norm therefore directly gives stability and performance margins with respect to unmodelled dynamics and parameter variation, without relying on a particular noise spectrum.
For that reason (H_\infty) methods are preferred in robust control: they address worst–case amplification and give guaranteed bounds in the presence of modelling error. (H_2)/LQG designs are optimal on average for a nominal model, but offer no worst–case guarantees and are not inherently robust to uncertainty.