Physiological Basis of the Electrocardiogram (ECG)
The electrocardiogram (ECG or EKG) is a non-invasive recording of the heart's electrical activity as detected by electrodes placed on the skin surface. It reflects the summation of action potentials generated by millions of cardiac myocytes (heart muscle cells).
Cardiac cells maintain a resting membrane potential of approximately -90 mV, primarily due to high intracellular K⁺ and low Na⁺/Ca²⁺, enforced by the Na⁺/K⁺-ATPase pump. Depolarization occurs when ion channels open: fast Na⁺ influx in phase 0 rapidly shifts the membrane to +30 mV, followed by a plateau (phase 2) from Ca²⁺ influx via L-type channels, enabling contraction. Repolarization (phases 3–4) restores the gradient via K⁺ efflux.
These action potentials originate in the sinoatrial (SA) node (pacemaker) and propagate as coordinated wavefronts through the atria, atrioventricular (AV) node, bundle of His, bundle branches, and Purkinje fibers to the ventricles. The ECG detects the extracellular voltage changes from this depolarization-repolarization sequence as a mean electrical vector projected onto limb and chest leads. Upward deflections indicate vectors toward the positive electrode; downward, away.
A normal ECG waveform (at 25 mm/s speed, 10 mm/mV amplitude) consists of:
1. P Wave (0.08–0.11 s duration, <2.5 mm amplitude)
- Represents atrial depolarization.
- Triggered by spontaneous depolarization of the SA node (in the right atrial wall near the superior vena cava superior).
- The impulse spreads rapidly through atrial internodal pathways and Bachmann's bundle, depolarizing the right atrium first (initial positivity in lead II), then left atrium.
- Results in atrial contraction (atrial systole), contributing ~20% to ventricular filling.
- Small amplitude due to thin atrial walls and small muscle mass.
2. QRS Complex (0.06–0.10 s duration, 5–30 mm amplitude)
- Represents ventricular depolarization (and partial override of terminal atrial repolarization).
- Begins after the PR interval (0.12–0.20 s), during which the impulse delays at the AV node (for atrial emptying) and travels via the His-Purkinje system.
- Q wave: Small initial negativity (0.01–0.03 s); left-to-right septal depolarization (septum depolarizes right-to-left, vector away from most leads).
- R wave: Tall positivity; apex-to-base depolarization of main left and right ventricular free walls (left ventricle dominates due to greater mass, vector leftward/downward).
- S wave: Negativity following R; depolarization of basal (upper) ventricles and posterobasal left ventricle.
- High amplitude and sharp shape due to thick ventricular myocardium (~10x atrial mass) and rapid conduction (2–4 m/s via Purkinje fibers). Precedes ventricular systole.
3. T Wave (0.16 s duration, 1–5 mm amplitude; follows ST segment, isoelectric plateau)
- Represents ventricular repolarization.
- Occurs as K⁺ efflux restores resting potential (phase 3), with epicardium repolarizing before endocardium (vector toward endocardium, upright in most leads).
- Timing lags depolarization due to the prolonged action potential duration (200–300 ms), ensuring contraction precedes relaxation.
- Smooth, broad shape reflects slower, more uniform repolarization. Precedes ventricular diastole.
In summary, the ECG traces the sequence: atria depolarize → brief pause → ventricles depolarize → ventricles repolarize. Abnormalities (e.g., prolonged QRS in bundle branch block) indicate conduction delays or ectopic foci, aiding diagnosis of ischemia, arrhythmias, hypertrophy, etc. Lead placement (e.g., Einthoven's triangle) orients vectors for 12-lead views.