Build a hospitalist handoff standard: I-PASS, checklist, and verification.
- User
Build a hospitalist handoff standard: I-PASS, checklist, and verification.
- Assistant
Hospitalist Handoff Standard: I-PASS Protocol with Checklist and Verification
Purpose
This standardizes patient handoffs between hospitalist shifts to improve communication, reduce errors, and ensure patient safety. It uses the I-PASS framework (Illness severity, Patient summary, Action list, Situation awareness/contingency plans, Synthesis by receiver), adapted for hospitalists. All handoffs must occur in a quiet, distraction-free environment (e.g., via phone, video, or in-person with EHR open). Handoffs cover all patients on the service.
Frequency: End-of-shift (e.g., 7 AM outgoing to 7 AM incoming; customizable).
Time Allocation: 1-2 minutes per patient; batch similar patients.
I-PASS Handoff Script/Template
Use this verbatim structure for each patient. Document in EHR handoff tool (e.g., under "Handoff Notes" section).
Component Description Example Script I: Illness Severity Stable, Watcher, Unstable. Color-code: Green (stable), Yellow (watcher), Red (unstable). Include early warning scores (e.g., MEWS, qSOFA). "Red: Unstable. MEWS 6, hypotensive on pressors." P: Patient Summary Core summary: Age, sex, diagnosis(es), key PMH, code status, allergies, pertinent interval events (last 24h). "65M, pneumonia + sepsis. PMH: DM, CHF. Full code. NKDA. Admitted 48h ago; cultures growing MRSA." A: Action List Prioritized to-do list for next 24h (meds, consults, labs, imaging, procedures). Include overnight tasks. "1. IDSA antibiotics q8h (vancomycin trough pending). 2. ID pulm today. 3. Repeat CXR AM. 4. D/C furosemide if UOP >1L." S: Situation Awareness & Contingency Plans Team awareness (caregivers, family), overnight events, barriers, contingencies ("If-then" plans). "Nurse aware of delirium; family updated. If BP <90, bolus 500ml NS then norepi. Code team paged x2 last night." S: Synthesis by Receiver Receiver summarizes back key points to confirm understanding. Sender clarifies. Receiver: "Got it: Red 65M MRSA pneumonia on pressors, pulm ID today, if hypotensive then fluids/norepi." Sender: "Correct." Full Patient Handoff Example:
I: Yellow: Watcher. MEWS 3 (tachypneic).
P: 72F, CHF exacerbation. PMH: Afib, CKD. DNR/DNI. PCN allergy. Diuresed 2L yesterday.
A: 1. Lasix 40mg IV BID if UOP <2L. 2. Echo stat. 3. Cardio fellow round AM. 4. BMP q12h.
S: On tele; nurse notes O2 need at night. Family requests hospice discussion. If saturations <90%, BiPAP trial.
S: [Receiver repeats/synthesizes]Pre-Handoff Checklist (Outgoing Provider)
Complete before handoff. Check off in EHR or paper tool.
- Updated EHR: Med rec, notes, orders current (within 30 min).
- Reviewed all patients: Vitals, labs, I/Os, imaging results.
- Prioritized list: Sort by acuity (Red/Yellow/Green).
- Code status/allergies verified.
- Pending items flagged (e.g., "Labs result pending").
- No distractions: Silence pagers/phones.
- Time estimate: <20 min total for service.
Handoff Checklist (Both Providers)
Use during handoff.
During Handoff Completed? Verbal I-PASS for each patient. ☐ Receiver synthesis/read-back for each. ☐ Visual review of EHR/orders together. ☐ Escalations discussed (e.g., rapid response). ☐ Questions clarified. ☐ Total time: <2 min/patient. ☐ Verification & Post-Handoff
Ensures accountability and auditability.
- Immediate Verbal Confirmation: Receiver states: "I have synthesized and accept handoff."
- EHR Sign-Off:
- Outgoing: Electronically sign "Handoff Given" with timestamp.
- Incoming: Sign "Handoff Received & Accepted."
- Audit Trail: Handoff tool auto-logs participants, time, and checklist completion.
- Post-Handoff Review (Incoming):
- Review all patients in EHR within 1 hour.
- Flag discrepancies to outgoing via secure message.
- Quality Metrics (Monthly Audit):
- % Handoffs with full I-PASS documentation.
- Error rate (e.g., missed actions).
- Provider feedback survey.
- Target: 100% compliance; escalate misses to chief hospitalist.
Training & Implementation
- Onboarding: Mandatory 30-min simulation training.
- Tools: EHR template auto-populates I-PASS fields.
- Escalation: If incomplete, page supervisor.
- References: Based on I-PASS study (NEJM 2017); customizable per institution.
This standard reduces handoff errors by >30% per literature. Questions? Contact hospitalist leadership.