Explaining maximum power transfer and reflections
Maximum power transfer occurs when the load impedance is the complex conjugate of the source impedance, maximizing real power delivered. If there's a mismatch, part of the power reflects back, creating standing waves along transmission lines; these reduce power actually absorbed by the load, with the reflected fraction given by the magnitude squared of the reflection coefficient.
In its simplest form the maximum‑power‑transfer theorem says “make the load look like the source.” For a purely resistive d.c. circuit that means (R_\text{L}=R_\text{source}), and you end up with half of the source’s open‑circuit voltage across the load and (V_\text{oc}^2/4R_\text{source}) of real power being dissipated in it.
In a.c. circuits the same idea applies, but you have to take the reactive part into account. The available power is maximised when the load impedance is the complex conjugate of the Thevenin equivalent of the source, (Z_\text{L}=R_\text{S}-jX_\text{S}). That choice cancels the source reactance and splits the real part equally between source and load, so the load sees a real impedance and all of the voltage and current are in phase.
When the load is not matched to whatever is feeding it, two things happen:
-
The instantaneous voltage/current division changes, so the real power delivered to the load is less than the “available” (P_\text{av}) from the source. For a simple source (V_\text{S}) with impedance (Z_\text{S}) feeding a load (Z_\text{L}), the average power is
[
P_\text{L}=\frac{|V_\text{S}|^2,\Re{Z_\text{L}}}{|Z_\text{S}+Z_\text{L}|^2},
]
which reaches a maximum when (Z_\text{L}=Z_\text{S}^*).
-
In distributed systems such as RF transmission lines, the mismatch shows up as a non‑zero reflection coefficient (\Gamma=(Z_\text{L}-Z_0)/(Z_\text{L}+Z_0)). A fraction (|\Gamma|^2) of the forward power is reflected back toward the source, so only (P_\text{fwd},(1-|\Gamma|^2)) is absorbed on that first pass. The forward and reflected waves interfere, producing the familiar pattern of voltage and current maxima and minima along the line; the voltage standing‑wave ratio is (\mathrm{VSWR}=(1+|\Gamma|)/(1-|\Gamma|)).
In a lossless line with a well‑matched source, the reflected energy can bounce back and forth until it is eventually absorbed by the load; in a real system with losses or a non‑ideal source, the reflected power is dissipated as heat in the line or source. Either way, the presence of reflections and standing waves is an indication that you are not transferring as much power to the load as you could with proper matching.