Derive the buck converter transfer function relating output to input voltage times duty cycle. Analyze inductor volt-second balance in steady state during on and off times.
Assistant
Other models, same or similar prompt
Responses were produced in different, uncontrolled contexts (system prompts, settings, prior turns). This is not a benchmark.
This is a classic power electronics problem. I need to derive the transfer function for a buck converter, specifically the DC transfer function relating output voltage to input voltage and duty cycle. I'll also analyze the inductor volt-second balance.
Let me structure this systematically:
Buck Converter Topology and Operation
Steady-State Analysis
Inductor Volt-Second Balance
Transfer Function Derivation
Physical Interpretation
1. Buck Converter Topology
A buck converter consists of:
Input voltage (Vi)
Power switch (MOSFETs or similar) S1
Freewheeling diode D
Inductor L
Filter capacitor C
Output voltage Vo
2. Operating Principle
During the ON period (t = 0 to t = DTs):
Switch S1 is ON, diode D is OFF
The inductor is connected to the input voltage Vi
Current through the inductor increases
During the OFF period (t = DTs to t = Ts):
Switch S1 is OFF, diode D is ON
The inductor is connected through the diode to the output
Current through the inductor decreases
3. Inductor Volt-Second Balance
Let me analyze this carefully.
During ON time (duration = D·Ts):
Voltage across inductor: VL,on = Vi - Vo
Volt-seconds: (Vi - Vo) × D·Ts
During OFF time (duration = (1-D)·Ts):
Voltage across inductor: VL,off = -Vo
Volt-seconds: (-Vo) × (1-D)·Ts
For steady state, the flux through the inductor must return to the same value at the beginning and end of the switching cycle (inductor volt-second balance):
∫VL dt must equal zero over one complete cycle
During ON: VL = Vi - Vo
During OFF: VL = -Vo
Setting the total volt-seconds to zero:
(Vi - Vo) × D·Ts - Vo × (1-D)·Ts = 0
This yields the fundamental DC relationship:
Vo = D·Vi
The inductor current rises during the ON interval by ΔiL,on = (Vi - Vo)·D·Ts / L, then falls during the OFF interval when the diode conducts and the inductor voltage becomes -Vo, causing a current decrease of ΔiL,off = Vo·(1-D)·Ts / L. For steady-state operation, these changes must be equal, which confirms the volt-second balance and establishes that output voltage scales linearly with duty cycle. The transfer function shows that output voltage scales linearly with both input voltage and duty cycle: Vo = D × Vi. This means the converter steps down the input voltage, with the output always constrained by 0 ≤ D ≤ 1, ensuring Vo never exceeds Vi.
For the inductor current ripple, the peak-to-peak variation during the on-phase is ΔiL,up = (Vi - Vo) × D × Ts / L, while during the off-phase it's ΔiL,down = Vo × (1-D) × Ts / L. Substituting the steady-state relationship Vo = D·Vi simplifies the on-phase ripple to ΔiL,up = Vi(1 - D) × D × Ts / L.
The off-phase ripple becomes ΔiL,down = Vi·D·(1-D) × Ts / L, which equals the on-phase ripple—a key characteristic of steady-state operation. The total current ripple is therefore ΔiL = 2 × Vi·D·(1-D) × Ts / L, or equivalently ΔiL = Vi·D·(1-D) / (L·f) when expressed in terms of switching frequency.
The output voltage ripple depends on capacitor discharge during the diode conduction phase, where the charge transferred relates to the inductor current behavior.
For dynamic behavior, small perturbations in duty cycle around an operating point D produce output voltage changes according to δVo = Vi·δd, giving a transfer function of H_d(s) = Vi between duty cycle and output voltage perturbations. The input-to-output transfer function follows similarly.
Buck Converter Transfer Function Derivation
Circuit Configuration
A buck converter consists of:
Power switch S (MOSFET/BJT)
Freewheeling diode D
Inductor L and Capacitor C (LC filter)
Input voltage Vᵢ and Output voltage V₀
Steady-State Operating Modes
ON Time Phase (Duration: D·Tₛ)
Switch S is closed; diode D is reverse-biased
VL(on)=Vi−V
dtdiL
Current change:
ΔiL,on=L(V
OFF Time Phase (Duration: (1-D)·Tₛ)
Switch S is open; diode D conducts
VL(off)=−Vo
dtdiL
Current change:
ΔiL,off=−L
Inductor Volt-Second Balance
Key Principle: In steady-state, the net flux linkage change per cycle must return to zero.
∫0TsVLdt
Applying this condition:
(Vi−Vo)⋅D
Expanding:
Vi⋅D⋅Ts
Vi⋅D⋅Ts=V
DC Transfer Function
ViVo
Or equivalently:
Vo=D⋅Vi
Key Insights:
Output voltage equals input voltage multiplied by duty cycle
0 ≤ D ≤ 1 ensures V₀ ≤ Vᵢ (step-down converter)
Transfer function is independent of L, C, and switching frequency in DC steady-state
Inductor Current Ripple Analysis
Magnitude of Current Ripple:
Rising slope (ON):ΔiL,up=LV
Falling slope (OFF):ΔiL,down=
Total peak-to-peak ripple:ΔiL=L⋅f
where f = 1/Tₛ is the switching frequency.
Observations:
Ripple maximized at D = 0.5
Proportional to input voltage and inversely proportional to inductance and frequency
Higher L and f → lower ripple (smoother current)
Output Voltage Ripple
The capacitor maintains voltage during the OFF phase. The ripple is:
ΔVo≈8Cf
Or using the current ripple directly:
ΔVo=8LCf2
Small-Signal Transfer Functions
For perturbations around equilibrium point (D₀, Vᵢ₀):
1) Duty cycle to output:Hd(s)=d^
2) Input to output:Hi(s)=V
More complete form (considering LC dynamics):
H(s)=ViD
where R is load resistance and R_L is inductor series resistance.
Summary Table
Parameter
Expression
Notes
DC Gain
V₀/Vᵢ = D
Fundamental relationship
Current ripple
ΔiL = ViD(1-D)/(Lf)
Max at D=0.5
Voltage ripple
ΔV₀ ≈ ViD(1-D)/(8LCf²)
Decreases with higher L, C, f
ON-time inductor voltage
VL = Vi - V₀
Larger difference → steeper rise
OFF-time inductor voltage
VL = -V₀
Always negative
This analysis forms the foundation for buck converter design, control stability analysis, and component selection.