Draft a medical device SaMD/AI compliance checklist and PMS plan.
- User
Draft a medical device SaMD/AI compliance checklist and PMS plan.
- Assistant
SaMD/AI Medical Device Compliance Checklist and Post-Market Surveillance (PMS) Plan
Draft prepared by Sherlock, AI by Trailblazer Labs
Date: [Insert Current Date]
Scope: This checklist and PMS plan are designed for Software as a Medical Device (SaMD) incorporating AI/ML elements. They align with key regulations including EU MDR 2017/745 (Annex I, II, III), FDA SaMD Framework and AI/ML SaMD Action Plan, ISO 13485, IEC 62304, IEC 62366-1, ISO 14971, IMDRF SaMD guidance, and emerging AI-specific guidances (e.g., MDCG 2023-7, FDA Good Machine Learning Practice). Customize for jurisdiction, risk class (e.g., Class I-III or I-IV per MDR), and SaMD intended use. Not legal advice—consult regulatory experts.
1. SaMD/AI Compliance Checklist
Use this checklist during pre-market development, submission (e.g., EU Technical Documentation, FDA 510(k)/De Novo/PMA), and audits. Mark as Compliant (Y/N/NA), with evidence references.
1.1 Regulatory Classification and General Requirements
Item Description Y/N/NA Evidence 1.1.1 SaMD defined per IMDRF/FDA (standalone software with medical purpose; no hardware integration unless specified). 1.1.2 Risk classification completed (e.g., FDA I/II/III; EU Class I/IIa/IIb/III; IMDRF a/b/c/d based on significance of state, info, clinical condition). 1.1.3 AI/ML classification addressed (locked vs. adaptive/continuous learning models). 1.1.4 GSPR/QSR conformity declared (EU Annex I; FDA QSR 21 CFR 820). 1.1.5 UDI assigned and implemented (Unique Device Identification). 1.2 Quality Management System (QMS)
Item Description Y/N/NA Evidence 1.2.1 ISO 13485:2016 QMS certified/implemented (design controls, CAPA, complaints, etc.). 1.2.2 Software lifecycle processes per IEC 62304 (Class A/B/C based on risk). 1.2.3 Change control for AI model updates (versioning, retraining protocols). 1.3 Technical Documentation (EU Annex II/III; FDA Design History File)
Item Description Y/N/NA Evidence 1.3.1 Detailed description of SaMD/AI architecture (algorithms, data inputs/outputs, training/validation datasets). 1.3.2 Bill of materials/software architecture diagram. 1.3.3 Cybersecurity design (encryption, access controls, vulnerability assessments per FDA cybersecurity guidance). 1.3.4 Performance specs, algorithms, and limitations documented. 1.4 Risk Management (ISO 14971:2019)
Item Description Y/N/NA Evidence 1.4.1 Risk Management File (RMF) with hazard analysis, FMEA/FTA for SaMD/AI-specific risks (e.g., bias, overfitting, adversarial attacks). 1.4.2 AI risks mitigated: data bias, dataset diversity, explainability (e.g., SHAP/LIME), robustness testing. 1.4.3 Residual risks acceptable and disclosed in IFU. 1.4.4 Post-market risk integration (benefit-risk analysis). 1.5 Clinical Evaluation (MEDDEV 2.7/1 Rev 4; FDA Clinical Guidance)
Item Description Y/N/NA Evidence 1.5.1 Clinical Evaluation Plan (CEP) and Report (CER) with literature review, clinical investigations, or equivalence. 1.5.2 AI performance metrics: sensitivity/specificity, AUC-ROC, calibration plots; stratified by subgroups (bias analysis). 1.5.3 Real-World Evidence (RWE) plan if applicable for adaptive AI. 1.5.4 Scientific validity, analytical/clinical validation demonstrated. 1.6 Verification, Validation, and Usability
Item Description Y/N/NA Evidence 1.6.1 Software V&V per IEC 62304 (unit/integration/system testing). 1.6.2 AI-specific testing: dataset splits (train/valid/test), cross-validation, external validation sets. 1.6.3 Usability engineering per IEC 62366-1 (formative/summative testing with users). 1.6.4 Simulated use, stress testing, interoperability testing. 1.7 AI/ML-Specific Considerations (FDA GMLP; MDCG AI Guidance)
Item Description Y/N/NA Evidence 1.7.1 Dataset governance: source, size, diversity, preprocessing documented; bias mitigation (e.g., reweighting, augmentation). 1.7.2 Model transparency/explainability (e.g., feature importance). 1.7.3 Algorithm transparency (pre-determined vs. ML; training process). 1.7.4 Change management for model updates (Predetermined Change Control Plan for adaptive AI). 1.7.5 Ethical AI: fairness, accountability documented. 1.8 Labeling, Instructions for Use (IFU), and Promotion
Item Description Y/N/NA Evidence 1.8.1 IFU includes intended use, limitations, warnings (e.g., AI confidence scores, operator training). 1.8.2 Symbols per ISO 15223; multilingual as required. 1.8.3 Promotional claims substantiated (no off-label). 1.9 Pre-Market Submission Readiness
Item Description Y/N/NA Evidence 1.9.1 Notified Body/competent authority engagement (if Class IIa+). 1.9.2 Clinical trials registered (if required, e.g., ClinicalTrials.gov). 1.9.3 PMS/Vigilance plan in place (see Section 2). Completion Notes: Total items compliant: /. Gaps actioned by [date]. Auditor sign-off: ________________.
2. Post-Market Surveillance (PMS) Plan
Document Reference: [e.g., PMS-001 v1.0]
Device: [SaMD/AI Name, Model, UDI] | Risk Class: [e.g., IIb] | PMS Responsible: [QRA/Regulatory Lead]
Review Frequency: Annual (or post-update); integrate with PSUR (EU) / PMSR (FDA).
Objective: Proactively monitor safety, performance, and effectiveness post-market to detect signals, mitigate risks, and support lifecycle changes (MDR Art. 83-86, Annex III; FDA 21 CFR 803/822). For AI: Monitor drift, bias emergence, real-world performance.2.1 PMS Objectives and Scope
- Collect/analyze data on foreseeable risks, usability, clinical performance/benefits.
- Detect new/ emerging risks (esp. AI: dataset shift, adversarial inputs).
- Support PSUR/PMSR, CAPA, field safety notices, recalls.
- Metrics: Complaint rates, adverse events (MAUDE/EUDAMED), performance KPIs (e.g., AUC drift <5%).
2.2 Data Sources and Collection Methods
Data Source Collection Method Frequency Responsible Analysis Tool User complaints/helpdesk Automated ticketing (e.g., Zendesk), hotline Real-time Customer Support Trend analysis (Excel/Tableau) Adverse events/vigilance EUDAMED/FDA MedWatch/MDR reporting Real-time Pharmacovigilance Signal detection software (e.g., Oracle Argus) Registry/RWE studies EHR integration, patient registries Quarterly Clinical/HEOR Statistical software (R/Python) Literature/scientific PubMed/Google Scholar alerts Monthly Medical Affairs Review database User analytics/telemetry Usage logs, error rates, AI confidence scores Continuous Data Analytics ML monitoring (e.g., Evidently AI) Audits/capabilities Supplier audits, cybersecurity scans Annual QMS Audit reports PSUR inputs Sales/volume data, market feedback Annual Regulatory PMS database 2.3 Signal Detection and Risk Assessment
- Thresholds: Complaint rate >0.1%; performance degradation >10%; new risk probability >1/10,000.
- Methods: Statistical process control (SPC), Bayesian anomaly detection for AI drift; FMEA refresh annually.
- Escalation: Signals → Risk Review Board (within 7 days) → CAPA if confirmed.
- AI-Specific: Monitor input data drift (e.g., KS-test), model retraining triggers.
2.4 Reporting and Communication
Report Content Frequency Recipients PMS Report Data summary, signals, actions Annual NB/RA/Management PSUR (EU Class IIa+) Benefit-risk update, clinical data Every 2 years (post-CE mark) NB/EUDAMED Field Safety Notice Confirmed issues As needed Users/RA Trend Report AI performance KPIs Quarterly Internal 2.5 Resource Allocation and Training
- Team: QRA (lead), Data Scientist (AI), Clinical Expert.
- Budget: [e.g., $XXK/year for tools/studies].
- Training: Annual PMS/AI ethics for staff; SOPs: PMS-001, AI-MON-001.
2.6 Plan Review and Updates
- Review annually or post-model update/change.
- Metrics for PMS effectiveness: Signal detection rate >95%, time-to-resolution <30 days.
- Approval: ________________ Date: __________ Next Review: [Date +1yr].
Annexes: [PMS SOPs, Data Collection Forms, Signal Log Template].
This draft provides a robust starting point. For implementation, integrate into your QMS and validate with a mock audit. Questions? Provide specifics for tailoring (e.g., jurisdiction, AI type).