Deriving and comparing LMTD for heat exchangers
I derived the log mean temperature difference (LMTD) starting from differential heat transfer and energy balances, showing it as (ΔT₁ - ΔT₂)/ln(ΔT₁/ΔT₂) where ΔT₁ and ΔT₂ are temperature differences at the ends. For co-current flow, ΔT₁ = Th,in - Tc,in and ΔT₂ = Th,out - Tc,out; for counter-flow, ΔT₁ = Th,in - Tc,out and ΔT₂ = Th,out - Tc,in. I clarified that counter-flow yields a higher or more uniform LMTD, making it more efficient by providing a larger average driving force under the same inlet conditions and UA, allowing greater heat transfer or smaller exchanger area compared to parallel flow.Composing full LMTD derivation and explanation
I'm preparing a detailed answer that rigorously derives the log mean temperature difference (LMTD) starting from dQ = U ΔT(x) dA and energy balances for co-current flow, integrating to express area in terms of inlet/outlet temperature differences. This yields the standard LMTD formula ΔT_lm = (ΔT₁ - ΔT₂)/ln(ΔT₁/ΔT₂). I’ll then explain how ΔT₁ and ΔT₂ differ for counter-flow and co-current arrangements and clarify why counter-flow has a larger effective LMTD and thus higher heat transfer efficiency.
If you write down the heat balance on an elementary slice of a two–stream exchanger you arrive very quickly at the two ingredients that go into the log–mean form:
-
The rate of heat transfer is proportional to the local temperature driving force,
[
\mathrm{d}Q=U,\mathrm{d}A,[T_h(x)-T_c(x)]\equiv U,\mathrm{d}A,\Delta T(x),
]
with (U) taken as constant and no phase change.
-
The fluid temperatures change linearly with the heat duty because of the constant heat‑capacity rates (C_h=\dot m_h c_{ph}) and (C_c=\dot m_c c_{pc}). For example in co‑current flow a small amount of heat (\mathrm{d}Q) reduces the hot stream temperature by (\mathrm{d}T_h=-\mathrm{d}Q/C_h) and raises the cold stream temperature by (\mathrm{d}T_c=+\mathrm{d}Q/C_c), so the temperature difference across the wall changes as
[
\mathrm{d}\Delta T=\mathrm{d}T_h-\mathrm{d}T_c=-\Bigl(\frac{1}{C_h}+\frac{1}{C_c}\Bigr),\mathrm{d}Q.
]
Eliminating (\mathrm{d}A) between these two relations gives
[
\mathrm{d}A=\frac{\mathrm{d}Q}{U,\Delta T(Q)},\qquad \Delta T(Q)=\Delta T_1-\Bigl(\frac{1}{C_h}+\frac{1}{C_c}\Bigr)Q,
]
where (\Delta T_1) is the temperature difference at the inlet end. Integration from (Q=0) to the total duty (Q) then yields
[
A=\frac{1}{U}\int_0^{Q}\frac{\mathrm{d}Q}{\Delta T(Q)}
=\frac{1}{U},\frac{1}{1/C_h+1/C_c},\ln\frac{\Delta T_1}{\Delta T_2},
]
with (\Delta T_2) the temperature difference at the outlet end. Rearranging gives the familiar “(UA\Delta T)” form,
[
Q=U A,\Delta T_{\mathrm{lm}},\qquad
\Delta T_{\mathrm{lm}}=\frac{\Delta T_1-\Delta T_2}{\ln(\Delta T_1/\Delta T_2)}.
]
Exactly the same integration leads to the same logarithmic mean for a counter–current exchanger; the only difference is how you define the end–point differences. In parallel flow
[
\Delta T_1=T_{h,\mathrm{in}}-T_{c,\mathrm{in}},\qquad \Delta T_2=T_{h,\mathrm{out}}-T_{c,\mathrm{out}},
]
whereas in counterflow
[
\Delta T_1=T_{h,\mathrm{in}}-T_{c,\mathrm{out}},\qquad \Delta T_2=T_{h,\mathrm{out}}-T_{c,\mathrm{in}}.
]
Because in a countercurrent exchanger the hot stream always meets progressively colder cold fluid, the temperature difference is more nearly uniform along the length. For given inlet temperatures and the same heat duty, the “pinch” temperature difference at the cold end is larger in counterflow than in parallel flow, so the logarithmic mean of the two end differences is larger. Equivalently, for a given (U A) and inlet conditions a counterflow unit will transfer more heat or reach a higher cold‑side outlet temperature than a parallel unit. This more uniform driving force is what is meant when one says that counterflow is “more efficient”.