This is a complex structural engineering problem that requires a few assumptions and simplifications to solve here. Remember that the proposed solution is a first estimate based on approximate calculations and the given assumptions. For a final design, advanced analysis and local code must be consulted. We will run through some straightforward mechanical calculations for each check.
1. Buoyancy Check at Max Gravity Load
First, we need to calculate the weight of the dock section that the pontoons must support. The total load per square meter (P_total) is the sum of dead load (P_dead) and live load (P_live), and then calculate it per dock section:
P_total = P_dead + P_live = 0.6 kPa + 5 kPa = 5.6 kPa
Area of one section of the dock (A_dock_section) = Length × Width = 13m × 3m = 39 m²
Total load over one dock section (F_total) = P_total × A_dock_section = 5.6 kPa × 39 m² = 218.4 kN
Accounting for wind load (W_wind) and berthing energy (E_berthing) that acts on the dock, we simply add them directly as forces:
F_total = F_total + W_wind + E_berthing = 218.4 kN + 24.4 kN + 1.59 kN = 244.39 kN
Now, assuming you want 50% to 70% of your pipe area submerged under dead load, you would begin by finding the volume of water displaced by this load, which must be equal to or greater than the total load for buoyancy:
Total load in terms of water displaced (V_displaced) = F_total / (density of water * g), where g = 9.81 m/s², and the density of water is approximately 1000 kg/m³.
V_displaced = 244.39 kN / (9.81 m/s² * 1000 kg/m³) ≈ 24.93 m³
Each pontoon must displace half the volume under full load:
V_pontoon_full_load = V_displaced / 2 ≈ 24.93 m³ / 2 ≈ 12.47 m³
Now we can transition into diameter calculations for two scenarios: 50% and 70% submerged pontoon volumes:
For 50%:
V_pontoon_50% = V_pontoon_full_load / 0.5 = 24.93 m³
For 70%:
V_pontoon_70% = V_pontoon_full_load / 0.7 ≈ 17.81 m³
The volume of a cylindrical pontoon is πd²/4L_pontoon, where d is the diameter and L_pontoon is the length of the pontoon (equal to the length of the dock section, 13m). Solve for the diameter 'd' for both cases (50% and 70% submerged).
2. Lateral Loads - Shear and Flexure
Lateral loads (W_wind and E_berthing) will create shear and bending moment that the dock will have to resist. Since we don't have a specific connection design, we'll only do a preliminary calculation for the available shear and moment capacity of the pontoon pipes.
We can simply check that the lateral loads are within the design capacity of the docks in terms of shear and moment. The maximum shear force (V) and bending moment (M) would typically occur at the points of connection to the moorings. This is also dependent on the structural framing of the dock itself; therefore, further detailed design is necessary here.
3. Longitudinal Flexure - Wave Action
For the effect of waves on longitudinal flexure, we'd need to estimate how the buoyancy is distributed along the pontoon's length during a wave trough. In a simplified case, you could equate this to a loaded beam with specific 'missing' support sections under the waves, requiring you to calculate the moment (M_f) in these areas.
You can estimate that the buoyancy support is only available at the wave's crests. Estimating the distance between wave crests (λ) from wave theory, you can consider the wave speed (v) is v = √(gλ/2π). With a period (T) of 10 seconds, you have λ = (v*T)² * 2π/g. With this wavelength, you can approximate the number of wave crests under the dock section and consider the pontoon as a series of simply supported beams over this span presenting peak moments and shear at midspans and supports, respectively.
4. Serviceability Limit State - Vibration/Dock Movement
For vibration and movement, the natural frequency of the dock system and resulting accelerations should not cause discomfort to users. The system's natural frequency depends on the mass of the dock and the stiffness of the pontoons. A detailed analysis of this would typically use a finite element model or similar computational methods.
For a more comprehensive analysis and proper safety assurance, professional engineering software and further detailed calculations are required. The information provided here should only serve as a guideline for an initial design and must be verified and expanded with more detailed structural engineering work.