When there were three IVM-MII, sibling oocytes were included in Group 2: “scRNA-seq…
- User
When there were three IVM-MII, sibling oocytes were included in Group 2: “scRNA-seq assessment”. In this case, sibling oocytes were randomized between fresh, manual or semi-automated vitrified oocytes, and single-cell transcriptomes were analyzed and compared. Three in vivo MII oocytes were also included in Group 2 on the day of oocyte retrieval from a patient who was part of an oocyte donation program.
Oocyte conditioning Vitrification and warming processes were performed by the two same operators.
Manual vitrification-warming procedure (Reference method) MII were vitrified in a closed system (Rapid-I™, Vitrolife, Sweden) using the RapidVit™ Oocyte kit (Vitrolife, Sweden) containing ethylene glycol and propanediol, which are permeable cryoprotectants, and sucrose, acting as an extracellular cryoprotectant. The vitrification procedure was performed according to the manufacturer’s protocol. Each solution (Vitri 1™ Oocyte, Vitri2™ Oocyte and Vitri 3™ Oocyte) was warmed to 37 °C in a multi-well plate. The oocyte was transferred for 7 minutes in Vitri 1™ Oocyte, 4 minutes in Vitri 2™ Oocyte, and a maximum of 25 seconds in drops of Vitri 3™ Oocyte including the loading on cryodevice (Rapid-I) and immersion into liquid nitrogen. The vitrified oocytes were warmed with a RapidWarm™ Oocyte kit (Vitrolife, Sweden) at 37 °C. The Rapid-I was plunged into Warm 1™ Oocyte for 1 minute. The oocyte was then moved into Warm 2™ Oocyte for 3 minutes, Warm 3™ Oocyte for 5 minutes, and Warm 4™ Oocyte for 7 minutes. Immediately after warming, oocytes were loaded into the Embryoscope with Global media (Global, LifeGlobal, Denmark) for morphometric assessments or in a 4-well culture dish for transcriptomic assessment.
Semi-automated vitrification and warming with the GAVI® system MII oocytes were vitrified in the semi-automated vitrification group using GAVI®, as previously described by Roy et al. [37]. Oocytes were first equilibrated in VitBase solution for 5 minutes in an un-gassed incubator at 37 °C. In the meantime, the medium cartridge containing vitrification solutions VS1 and VS2 (ethylene glycol, dimethyl sulfoxide, trehalose and supplemented human serum albumin) and tip and seal cartridges were loaded into the GAVI® system. The oocytes were then individually loaded into a device called a “Pod” and loaded into GAVI®. The oocyte vitrification protocol was selected, run and once finished, the cassette was manually removed and dunked into liquid nitrogen. Oocytes were stored in a liquid nitrogen tank before being warmed as per Genea BIOMEDX protocol using Gems Warming solutions® (Genea, Sydney, Australia). After a brief warming in a 37 °C water batch, 10 μl of WarmSol1 was dispensed in less than 20 seconds in the Pod, over a period of 1 minute. Oocytes were then transferred for 1 minute in WarmSol1, 3 minutes in WarmSol2, 5 minutes in WarmSol3, 1 minute in WarmSol3 before being transferred into Global media (Global, LifeGlobal, Denmark).
Survival rate, Morphometric assessment, Resistance to micro-injection The primary outcome of this study was the survival rate (i.e. the number of intact oocytes after thawing divided by the total number of warmed oocytes). To evaluate post thawing oocyte rehydration for oocytes included in Group 1, the oocyte surfaces (i.e. ooplasm surface) were estimated with the Embryoscope tool immediately after thawing, and then one, two and three hours post thawing. To assess the oocyte’s resistance to micro-injection in Group 1, a secondary outcome was the survival rate after “empty” micro-injection (without spermatozoa) performed 3 hours after thawing, specified as the number of intact oocytes after the micro-injection gesture.
- Assistant
Great question — the paper is comparing manual and semi-automated vitrification methods for MII (mature) oocytes, with single-cell RNA-seq as one of the key assessments. The control group depends on which comparison you’re focusing on:
🔹 Primary Experimental Comparison: The study is designed to test whether semi-automated vitrification improves oocyte survival and quality compared to manual vitrification. So:
Manual vitrification (using the Rapid-I™ system) is the control group — the standard/reference method.
Semi-automated vitrification (using the GAVI® system) is the experimental group — the new/test method.
This is confirmed by the following phrases:
“Manual vitrification-warming procedure (Reference method)”
- User
- Assistant
- User
what is vitrification?
- Assistant
Vitrification is a rapid freezing technique used to preserve biological cells (like oocytes or embryos) by turning them into a glass-like solid without forming damaging ice crystals.
🔹 Why is vitrification used? When you freeze cells slowly, ice crystals can form and puncture the cell membrane, damaging or killing the cell. Vitrification avoids this by freezing so quickly that ice doesn’t have time to form.
🔹 How does vitrification work?
Cryoprotectants: Oocytes are first exposed to high concentrations of cryoprotectant chemicals (like ethylene glycol, DMSO, sucrose). These prevent ice crystal formation.
Rapid cooling: The oocytes are then plunged into liquid nitrogen (at -196°C), freezing them almost instantly into a glassy, solid state.
Storage: They’re stored in liquid nitrogen tanks until needed.
Warming: When thawed, the oocytes are quickly warmed and rehydrated in decreasing concentrations of cryoprotectants to prevent damage from osmotic shock.
🔹 What is vitrification used for?
Fertility preservation (for cancer patients, egg donors, or women delaying childbearing)
- User
can you make a dictionary:
GSM6212026 oocyte, fresh, patient1 GSM6212027 oocyte, manual, patient1 GSM6212028 oocyte, auto, patient1 GSM6212029 oocyte, fresh, patient2 GSM6212030 oocyte, manual, patient2 GSM6212031 oocyte, fresh, patient3 GSM6212032 oocyte, fresh, patient4 GSM6212033 oocyte, manual, patient4 GSM6212034 oocyte, auto, patient4 GSM6212035 oocyte, manual, patient5 GSM6212036 oocyte, auto, patient5 GSM6212037 oocyte, manual, patient6 GSM6212038 oocyte, auto, patient6 GSM6212039 oocyte, auto, patient2 GSM6212040 oocyte, manual, patient3 GSM6212041 oocyte, auto, patient3 GSM6212042 oocyte, fresh, patient7 GSM6212043 oocyte, manual, patient7 GSM6212044 oocyte, auto, patient7 GSM6212045 oocyte, fresh, patient6
GSM id to auto, manual, or fresh to patient
- Assistant
Sure! Here's the dictionary mapping each GSM ID to a tuple of (method, patient), where the method is one of "fresh", "manual", or "auto": pythonCopyEditgsm_dict = { "GSM6212026": ("fresh", "patient1"), "GSM6212027": ("manual", "patient1"), "GSM6212028": ("auto", "patient1"), "GSM6212029": ("fresh", "patient2"), "GSM6212030": ("manual", "patient2"), "GSM6212031": ("fresh", "patient3"), "GSM6212032": ("fresh", "patient4"), "GSM6212033": ("manual", "patient4"), "GSM6212034": ("auto", "patient4"), "GSM6212035": ("manual", "patient5"), "GSM6212036": ("auto", "patient5"), "GSM6212037": ("manual", "patient6"), "GSM6212038": ("auto", "patient6"), "GSM6212039": ("auto", "patient2"), "GSM6212040": ("manual", "patient3"), "GSM6212041": ("auto", "patient3"), "GSM6212042": ("fresh", "patient7"), "GSM6212043": ("manual", "patient7"), "GSM6212044": ("auto", "patient7"), "GSM6212045": ("fresh", "patient6"), }
Let me know if you want the inverse mapping (grouped by patient or by method), or a CSV version!
- User
im in a folder. this folders has subfoders called GSE205417_D#. the # coresponds to the number after patient# in the tuple. inside the donor folder are sample subfolders(fresh, auto, manual). please rename the subflders to their coresponding GSM id
- Assistant
You can use the following bash script to rename the fresh, auto, and manual subfolders inside each GSE205417_D# folder to their corresponding GSM ID, based on your provided dictionary:
✅ Bash Script: bashCopyEdit#!/bin/bash
Define GSM dictionary as associative array
declare -A gsm_dict=( [1,fresh]="GSM6212026" [1,manual]="GSM6212027" [1,auto]="GSM6212028" [2,fresh]="GSM6212029" [2,manual]="GSM6212030" [2,auto]="GSM6212039" [3,fresh]="GSM6212031" [3,manual]="GSM6212040" [3,auto]="GSM6212041" [4,fresh]="GSM6212032" [4,manual]="GSM6212033" [4,auto]="GSM6212034" [5,manual]="GSM6212035" [5,auto]="GSM6212036" [6,manual]="GSM6212037" [6,auto]="GSM6212038" [6,fresh]="GSM6212045" [7,fresh]="GSM6212042" [7,manual]="GSM6212043" [7,auto]="GSM6212044" )
Traverse through donor folders
for donor_folder in GSE205417_D*; do donor_id="${donor_folder##*D}" # Extract donor number
Loop through methods
- User
this is the supplementary data that has been provided: GSE205417_normalized_counts_RLE.xls.gz 1.7 Mb (ftp)(http) XLS GSE205417_raw_counts.tsv.gz
what does the raw coutns ccontian
- Assistant
The file GSE205417_raw_counts.tsv.gz contains the raw gene expression counts from the single-cell RNA-sequencing (scRNA-seq) of the oocytes described in the paper. Here's what that means in detail:
🔬 What's inside GSE205417_raw_counts.tsv.gz? It is a tab-separated file (TSV) that likely has:
Rows = Genes (each row corresponds to one gene, often identified by Ensembl ID or gene symbol)
Columns = Samples (each column corresponds to one oocyte/sample, probably labeled by GSM ID like GSM6212026, etc.)
🔹 So the matrix looks like: Gene IDGSM6212026GSM6212027GSM6212028...ENSG000001234561249ENSG00000123457020............ Each cell in the matrix is the raw count of RNA-seq reads that were assigned to that gene in that sample.
🧪 What do raw counts represent? Raw counts are the unprocessed output from quantifying RNA-seq reads. They represent:
The number of sequencing reads mapped to each gene in each oocyte.
- User
can i use this in scanpy for anndata
- Assistant
Yes, you can absolutely use the GSE205417_raw_counts.tsv.gz file in Scanpy by converting it into an AnnData object, which is the core data structure used in Scanpy for single-cell analysis. Here’s how you can do it:
✅ Step-by-Step: Load raw_counts.tsv.gz into AnnData pythonCopyEditimport scanpy as sc import pandas as pd
Load the raw count matrix
raw_counts = pd.read_csv("GSE205417_raw_counts.tsv.gz", sep='\t', index_col=0)
Check the shape and format
print(raw_counts.shape) print(raw_counts.head())
Convert to AnnData
adata = sc.AnnData(raw_counts.T) # Transpose so cells are rows, genes are columns
Optionally, store gene names and sample names
adata.var_names = raw_counts.index # gene IDs adata.obs_names = raw_counts.columns # GSM IDs
Now adata is ready for Scanpy processing
adata.raw = adata # Store raw counts if needed
🔍 Notes:
.T is important because Scanpy expects samples (cells/oocytes) as rows, and genes as columns.
- User
does it contain barcodes?
- Assistant
No, the file GSE205417_raw_counts.tsv.gz most likely does not contain barcodes, and here’s why:
🔬 Nature of the experiment: This dataset comes from single-cell RNA-seq of human oocytes, but each sample is a full single oocyte, not droplet-based (like 10x Genomics). The paper states:
“The free-zona pellucida oocyte [...] was individually placed in a lysis buffer…”
This means they processed one cell at a time, not via high-throughput droplet barcoding.
🧾 So what’s in the file? The raw count file is structured more like bulk RNA-seq per cell, so:
Each column = one oocyte/sample (labeled with GSM ID)
Each row = one gene
No cell barcodes needed, because each sample is already a single oocyte and its identity is tracked by GSM ID.
🔍 TL;DR: FeaturePresent?NotesBarcodes❌ NoNot needed — one oocyte per sampleGSM IDs✅ YesColumn names = GSM identifiersGene IDs✅ YesRow index = gene identifiers (probably Ensembl or gene symbols)
If you still want to create a barcode field (e.g. for compatibility with tools expecting it), you could simulate it using the GSM IDs: pythonCopyEditadata.obs["barcode"] = adata.obs_names
Let me know if you'd like help inspecting or verifying the file contents directly.
- User
- Assistant
To associate the columns in your file (D655T20, D655T21, ..., etc.) with the donor (patient) number, you’ll need to map each of those sample IDs (e.g., D655T20) to their corresponding GSM ID, and then use your previous GSM → patient mapping. Let’s walk through how to do this in a structured way.
🧾 Step 1: Use a Sample Metadata Table The file you pasted appears to use internal sample IDs like D655T20, which are aliases for GSM IDs (e.g., GSM6212026). These mappings are typically found in the GSE metadata or Series Matrix File from GEO. To proceed, you need one of the following:
Supplementary me
Other models, same or similar prompt
Responses were produced in different, uncontrolled contexts (system prompts, settings, prior turns). This is not a benchmark.