To prevent updating Modified and Modified By fields when updating a folder's column in SharePoint CSOM, use the following methods:
1. Use SystemUpdate() Instead of Update()
This is the primary solution to retain metadata:
folderItem[columnName] = newValue;
folderItem.SystemUpdate(false); // false = no version increment
ctx.ExecuteQuery();
- Why it works:
SystemUpdate() bypasses standard auditing, preserving Modified/Modified By[1][2][8].
- Limitations: Still triggers workflows/event receivers[6].
2. Manually Preserve Original Values (Alternative)
If SystemUpdate() isn't available (older CSOM versions), reset the fields:
// Capture original values first
var originalModified = folderItem["Modified"];
var originalModifiedBy = folderItem["ModifiedBy"];
// Update your column
folderItem[columnName] = newValue;
// Restore original metadata
folderItem["Modified"] = originalModified;
folderItem["ModifiedBy"] = originalModifiedBy;
folderItem.Update(); // Standard update
ctx.ExecuteQuery();
- Warning: Requires elevated permissions to modify system fields[3][7].
- Versioning: Creates a new version unless
EnableVersioning=false[3][5].
3. Use UpdateOverwriteVersion() (Advanced)
For direct control over system fields:
folderItem[columnName] = newValue;
folderItem["Modified"] = DateTime.Parse("2020-01-01"); // Set custom date
folderItem["Editor"] = 1073741823; // User ID for Modified By
folderItem.UpdateOverwriteVersion();
ctx.ExecuteQuery();
- Requirements:
- Disable
EnableVersioning on the list[3][7].
- Use
ForceCheckout = false[3].
- Use Case: Forced metadata changes without versioning[5][7].
Key Recommendations
| Method | Preserves Metadata? | Version Increment? | Complexity |
|---|
SystemUpdate() | ✅ Yes | ❌ No (if false) | Low |
| Manual Field Reset | ✅ Yes | ✅ Yes | Medium |
UpdateOverwriteVersion() | ❌ No | ❌ No | High |
Best Practice: Use SystemUpdate(false) unless you need to modify system fields directly[1][2][8]. For advanced scenarios, combine with ValidateUpdateListItem as shown in [5].