I am doing cyclic voltammetry of platinum sample with 50 mV/s speed in HClO4 and there…
- User
I am doing cyclic voltammetry of platinum sample with 50 mV/s speed in HClO4 and there is a peak at 0.7 V with respect to RHE. What does this peak mean
- Assistant
In cyclic voltammetry of platinum in perchloric acid (HClO₄), a peak at approximately 0.7 V versus the reversible hydrogen electrode (RHE) is typically associated with the reduction of platinum oxides formed during the anodic sweep. As the potential increases beyond 0.6 V, the platinum surface undergoes oxidation, leading to the formation of platinum oxide species. Upon reversing the scan direction, these oxides are reduced back to metallic platinum, resulting in a cathodic peak around 0.7 V[1].
The exact potential at which this reduction peak appears can vary depending on factors such as the specific crystallographic orientation of the platinum electrode and the electrolyte composition. For instance, studies have shown that on Pt(111) electrodes, a broad cathodic peak is observed at approximately 0.7 V during the reverse scan, corresponding to the reduction of platinum oxides formed at higher potentials[1].
Other models, same or similar prompt