Below is the “short-version” (how to make the box send BUSY / CONGESTION) and then a more detailed walk-through that also explains why you cannot let a TA410 play a custom voice prompt by itself.
═════════════════════════════════════════════════════════
QUICK ANSWER
═════════════════════════════════════════════════════════
- Log in to the TA410 web GUI.
- VoIP Settings ➜ Advanced (or Gateway Settings ➜ Advanced on some firmware).
- Find the block called “Return Code When …”.
- In the line “SIP Server Unreachable / Trunk Unregistered”
put 486 (Busy Here) or 603 (Decline) – either one will give the PSTN caller a busy tone.
- Save ► Apply ► (restart is NOT required on current firmware).
Result:
If the SIP account that the FXO port is supposed to use is not registered, the TA410 will pick the line, send the chosen SIP error to the PSTN side and the caller will immediately hear a standard busy tone.
═════════════════════════════════════════════════════════
STEP-BY-STEP WITH SCREENSHOTS IN WORDS
═════════════════════════════════════════════════════════
-
Log in as admin.
-
Top menu “Gateway” → sub-menu “VoIP Settings” → tab “Advanced”.
(On early firmware it is “Gateway Settings” → “Advanced”.)
-
Scroll down until you see a table that looks like this:
┌────────────────────────────────────────────┐
│ Return Code When … │ Default │
│ ───────────────────────────── │ ───────── │
│ Called party is busy │ 486 │
│ SIP server is unreachable │ 480 │ ← we change this line
│ No matching DID/Route │ 404 │
└────────────────────────────────────────────┘
-
Change “SIP server is unreachable” (sometimes labelled “Trunk Unregistered / Registration Failed”) from 480 or 503 to 486 (Busy Here) or 603 (Decline).
• 486 → classical busy tone
• 603 → “error” tone (often the same as busy, depends on the Telco)
-
Click “Save”, then “Apply”.
No reboot is required on firmware ≥ 13.18.0.x. On older releases the GUI will ask for one; just follow it.
═════════════════════════════════════════════════════════
WHY ONLY BUSY / CONGESTION, NOT A VOICE MESSAGE
═════════════════════════════════════════════════════════
• The TA-series gateways are not PBXs – they have no sound files/IVR module.
• They can only pass audio coming from one side to the other or generate standard call-progress tones (ringback, busy, congestion).
• Therefore you can return any SIP error code you like (486, 503, 404, …) and the gateway will translate that into the corresponding PSTN tone, but it cannot play a recorded message such as “All our operators are offline, please call later”.
If you really need a spoken announcement you have two options:
-
Put a little PBX (FreePBX, Yeastar S-Series, 3CX, etc.) in front.
• Let the FXO gateway send the call to a dummy IVR extension on that PBX.
• In the PBX choose “If all extensions are UNAVAILABLE –> Play Recording –> Hangup”.
-
Ask your Telco to activate a network-side announcement when the line is busy.
═════════════════════════════════════════════════════════
TROUBLESHOOTING TIPS
═════════════════════════════════════════════════════════
• After changing the return code, make an incoming call while the SIP trunk is not registered. You should hear busy immediately, not endless ringing.
• If you still hear ringing, clear the browser cache and verify that the value really got written to the configuration (older firmware occasionally ignored the first click on “Save”).
• Use the built-in “PCAP Capture” tool (Maintenance ➜ Toolbox ➜ Packet Capture) to prove that the gateway is now emitting a 486/603.
═════════════════════════════════════════════════════════
SUMMARY
═════════════════════════════════════════════════════════
• TA410 can return standard SIP error codes when its SIP account is offline.
• Configure that under VoIP Settings ➜ Advanced “Return Code When …”.
• 486 or 603 will translate to a busy tone for the PSTN caller.
• Playing an actual voice prompt is outside the scope of TA-series gateways; you need a PBX or a Telco service for that.