Your colleague is giving you an important configuration tip related to SNMP (Simple Network Management Protocol) setup, particularly in the context of CCM (Central Control Monitoring) and other systems like Icinga (on ANR or ANS) and RADARGUI.
Let’s break down what your colleague means:
🔧 Original Note:
SNMP Alert Destination: Align the SNMP setup as existing configuration for CCM.
This means you should configure the SNMP alert destination (e.g., where SNMP traps are sent) to match the current (or known good) configuration used by CCM.
💡 Colleague's Comment:
Tip, check this. The newer software default disables SNMP v2. CCM, (the Icinga on the ANR or ANS) and RADARGUI do not use SNMPv3 at the moment.
Here's what that means:
-
Newer software versions disable SNMP v2 by default
- Many modern network devices and monitoring tools now disable SNMP v2c by default due to security concerns.
- SNMP v2c (commonly referred to as just SNMP v2) is older and less secure than SNMP v3.
-
CCM, Icinga (ANR/ANS), and RADARGUI still rely on SNMP v2c
- These systems do not currently support SNMP v3, which is more secure but also more complex to configure.
- So even though newer software might prefer or enforce SNMP v3, you must continue using SNMP v2c for compatibility with these monitoring tools.
-
Practical Implication
- If you're configuring a device to send SNMP traps/alerts to CCM, Icinga, or RADARGUI, you need to make sure SNMP v2c is explicitly enabled, especially if it's disabled by default in the latest firmware/software.
- You'll also want to ensure that community strings (used in SNMP v2c) are properly configured, usually
public or a custom read-only string.
🛠 What You Should Do:
- Check the SNMP settings on the device or system you're configuring.
- Ensure SNMP v2c is enabled, even if the software defaults to disabling it.
- Use the correct community string (like
public) so that CCM and other tools can receive and interpret the SNMP traps.
- Make sure trap destinations (IP addresses/hostnames) align with where CCM, Icinga, or RADARGUI are listening for SNMP traps.
Summary:
Your colleague is reminding you that while newer systems may default to disabling SNMP v2c (because SNMP v3 is more secure), your environment still relies on SNMP v2c because CCM, Icinga (ANR/ANS), and RADARGUI don't yet support SNMP v3. So you need to explicitly enable and configure SNMP v2c when setting up SNMP alerts.
Let me know if you want help writing/configuring actual SNMP settings for a specific platform (like Linux, Cisco, Juniper, etc.).