Okay, in the context of pool timers, that string of information describes the electrical specifications of the pool pump motor that the timer will be controlling.
Here's a breakdown:
-
1 HP (Horsepower):
- This is the mechanical power output of the pool pump motor.
- Context for Timer: The timer needs to be rated to handle a motor of this size. Timers often have an HP rating (e.g., "Rated for up to 1.5 HP @ 120V"). Your timer's HP rating must be equal to or greater than the pump's HP.
-
15 FLA (Full Load Amps):
- This is the amount of electrical current (in Amperes) the motor is expected to draw when it's running under its normal, full operational load (i.e., pumping water at its rated capacity).
- Context for Timer: This is a very important specification. The electrical contacts inside the timer must be able to safely carry this amount of current continuously without overheating or failing. The timer's amperage rating must be at least 15A, and ideally a bit higher for a safety margin (e.g., a 20A or 30A rated timer).
-
90 LRA (Locked Rotor Amps):
- This is the very high inrush current the motor will draw for a brief moment when it first starts up, or if the motor shaft is "locked" (unable to turn). It can be 5-7 times (or more) the FLA.
- Context for Timer: The timer's contacts must be robust enough to handle this surge of current without arcing excessively or welding themselves shut. While not always explicitly listed as "LRA rating" on basic timers, a timer rated for the correct HP and FLA at the given voltage is generally designed to withstand the typical LRA associated with that motor size.
-
@ 120 VAC (Volts Alternating Current):
- This is the operating voltage for the pool pump motor.
- Context for Timer: The timer itself must also be designed to operate at 120 VAC and switch a 120 VAC load. You cannot use a 240 VAC timer for a 120 VAC pump, or vice versa, without proper wiring and potentially damaging the equipment or creating a safety hazard.
In Summary for Pool Timers:
When you see "1 HP, 15 FLA, 90 LRA @ 120 VAC" on a pool pump, you need to select a pool timer that is:
- Rated for at least 1 HP at 120 VAC.
- Rated for at least 15 Amps (FLA), preferably higher (e.g., 20A, 30A, or 40A). The timer's general amperage rating should cover the FLA comfortably.
- Designed to operate on a 120 VAC circuit.
If you choose a timer that is underrated for these specifications, it can lead to:
- Overheating of the timer contacts and internal wiring.
- Arcing and pitting of the contacts.
- Contacts welding shut (pump stays on) or failing to make contact (pump won't turn on).
- Premature failure of the timer.
- A potential fire hazard.