This Function Test document provides comprehensive testing procedures and acceptance criteria for the hardware supplied for the Hong Kong Vessel Traffic Services System(HKVTSS). The testing covers 23 HPE ProLiant servers comprising three different configurations.
The purpose of the function test is to demonstrate that the system meets the requirements as described in the above mentioned contract.
2 Document Overview
This document specifies the environment, preparations, and procedures to be executed for the SAT. It includes the specification of simulated data (if applicable) and test environment.
2.1 Test set-up
The tests to be executed are described with the following items:
Item Description
Description A short description of the test. A reference to a requirement can be made.
Mode A description of the initial situation which is required to start the test.
Input Actual input(s) to be made to execute the test.
Result Required results after the execution of the input(s). When this result is met, the test is considered as successful. The related Preliminary System Proposal descriptions are considered as sufficiently demonstrated.
In case the item description and/or mode do not provide additional information, these items can be omitted.
Test Environment Requirements:
• Stable power supply (240V, 50Hz) with appropriate power distribution
• Network connectivity for iLO access
• Temperature controlled environment (20-25°C)
• Test workstation with web browser for iLO interface access
• KVM console or monitor/keyboard for initial setup
Required Test Equipment:
• Network cables (Cat6 or higher)
• Power cables (C13-BS-1363A UK/HK/SG standard)
• USB keyboard and mouse for initial configuration
• Monitor with appropriate video cables
2.2 Accuracy
Numeric values mentioned in this document are assumed to be accurate until the last decimal place; e.g. 10.1 NM means a value between 10.05 NM and 10.15 NM. Exceptions to this rule are explicitly mentioned.
For hardware specifications:
• Memory capacities are exact values (e.g., 32GB, 128GB, 256GB)
• Storage capacities follow manufacturer specifications
• Power ratings are nominal values
2.3 Duration of the tests
The table below gives the estimated time to execute the tests of this procedure.
Test Estimated time
[hours]
3.1 Visual Inspection
3.2 System Boot and iLO Verification
3.2.1 H1 Configuration (HPE ProLiant DL360 Gen11 Silver server)
Boot Verification
iLO Access and License
Hardware Detection via iLO
System Health via iLO
Firmware and Driver Version Check
3.2.2 H3 Configuration (HPE ProLiant DL380 Gen11)
Boot Verification
iLO Access and License
Hardware Detection via iLO
System Health via iLO
Firmware and Driver Version Check
3.2.3 H5 Configuration (HPE ProLiant DL360 Gen11 Gold server)
Please add description to check the server chassis is undamaged, check rack ears, fan modules, drive bays and power units for physical defects to the 3.1 visual inspection par.
Assistant
I'll help you enhance the Visual Inspection section by adding more detailed criteria for checking the server chassis and components. Here's a suggested expanded description for the 3.1 Visual Inspection section:
3.1 Visual Inspection
During the visual inspection, carefully examine each server for the following criteria:
Chassis Integrity:
Check the entire server chassis for any signs of physical damage, dents, cracks, or deformation
Verify that all external surfaces are intact and free from significant scratches or impact marks
Rack Mounting Components:
Inspect rack ears for straightness and proper alignment
Confirm all rack mounting screws are present and securely fastened
Check for any bending or warping of rack mounting brackets
Fan Modules:
Visually inspect all fan modules for:
Physical damage or cracks
Secure mounting
No visible debris or obstruction
Consistent positioning and alignment
Drive Bays:
Examine drive bays for:
Proper alignment
No visible damage to bay covers or interfaces
Blanking panels in place for empty bays
No signs of corrosion or mechanical stress
Power Supply Units:
Check each power supply unit for:
Physical integrity
Secure mounting
No visible damage to power connectors
Proper seating in the chassis
Presence of all required power cables
Additional Checks:
Verify serial number matches documentation
Confirm no loose components or internal debris
Check for any signs of liquid damage or corrosion
Ensure all external ports and connectors are clean and undamaged
Recommended Documentation:
Take clear photographs of any identified issues
Note any observations in the "Comments" column
Mark each server as "OK" or "NOK" (Not OK) based on findings
This expanded description provides a comprehensive approach to visual inspection, ensuring thorough examination of the server hardware before proceeding with further testing.