i'm trying to set up a logical switch on a radiomaster pocket for a low battery voltage…
- User
i'm trying to set up a logical switch on a radiomaster pocket for a low battery voltage warning sound through telemetry, but no sound is playing. i want to hear a warning sound when my battery voltage on the flight controller drops below 3.4v and i have an a<x function on the logical switch page for v1 volt v2 3.4v (also AND switch SBdown so the alarm is only when armed) with a 1.0 delay. are there any settings or changes to make so i hear the alarm. the volume is on because all other alarms are playing.
- Assistant
Here’s a step-by-step checklist to get that low-voltage “beep” working on your RadioMaster Pocket (assuming you’re on OpenTX/EdgeTX):
-
Verify your FC-to-TX telemetry
• In MODEL → TELEMETRY → SENSORS, make sure your flight-controller’s battery voltage is actually bound in and shows up (usually as “Vf” or “A1/V1”).
• Go to your Telemetry screen in flight mode and confirm you can see the real-time voltage readout. -
Build your Logical Switches
a) L1 → Vf < 3.4 V
– Type: A<X
– Source A: your battery-voltage sensor (e.g. “Vf”, “V1” or “A1”)
– Value: 3.4
– No delay yet—keep it instant for testing.
b) L2 → L1 AND SB↓ (your “armed” switch)
– Type: AND
– Sources: L1, SB (or whatever your arming switch is) -
Assign a Special Function to play the alarm
In MODEL → SPECIAL FUNCTIONS, add a new line:
• Function: Play Track (or Play Sound)
• Source: L2
• Parameter: choose a system alarm (e.g. “battery_low.wav”) or your own wav file in SOUNDS/*.wav
• Repeat: While active
• Interval: e.g. 2 s (so it beeps every 2 seconds while L2 is true) -
Volume & Delay checks
• Make sure Master Volume (SYS → AUDIO → Volume) is up.
• If you want a 1 s “arming-delay,” go back and edit L1 or L2 to add an OFF or ON delay—e.g. L2 ON delay = 1.0 s. -
Test & Troubleshoot
• Remove the SB↓ from L2 for an “unarmed” test: does L1 alone now trigger the sound as soon as Vf < 3.4?
• If still silent, on a bench pull down a resistor on the battery-input so Vf reads < 3.4 V and watch the Special Functions “expanded view” to see if your SF line ever turns green.
• Double-check you selected the correct sensor ID (V1 vs A1 vs Vf).
BONUS: You can also set up a native telemetry alarm in TELEMETRY → ALARMS: choose your Vf sensor, set “Critical < 3.4 V → Warning,” and the radio will play its built-in voice prompt without needing an SF.
Once you’ve confirmed L2 really goes “ON” under 3.4 V, your SF will fire the audio file and you’ll get your beep-beep-beep low-battery warning. 👍
-
- User
the telemetry source is a 4in1 iRX4 lite using FlySky_2A, and the other available telemetry sensors from the board are TRSS, RSSI and RQly. the "Volt" telemetry sensor on the telemetry page shows an accurate readout of the FC voltage but the logical switch page also shows Volt+ and Volt- as V1 source options.
- Assistant
Here’s the key to getting that 4-in-1 “Volt” sensor to trigger your low-battery beep:
-
Make sure your voltage really is seen as an analog (Vfas) sensor
• Go to MODEL → TELEMETRY → SENSORS. You should see “Volt” listed, type “Vfas” or “Voltage”.
• If it’s showing up as a “Custom” sensor, you won’t get the V1/V2 analog slots—edit it and set the Type to “Voltage” (Vfas).
• Once you do that, you’ll see it again in the Logical Switch Source list as “Volt+” (the total pack voltage). -
Build a Logical Switch that trips below 3.4 V
• L1: Type = A < X
Source A = Volt+
Value = 3.4
(leave delays = 0 for now, just to bench-test)
• L2: Type = AND
Source A = L1
Source B = SB-Down (or whatever your “armed” switch is)
ON-Delay = 1.0 s (if you really want a 1 sec “arming” delay) -
Hook up a Special Function to play your beep
• MODEL → SPECIAL FUNCTIONS → (new line)
– Function: Play Track (or Play Sound)
– File: pick one of your WAVs or use a built-in alarm e.g. “battery_low.wav”
– Source: L2
– Switch: — (you already have L2 as your condition)
– Repeat: While active
– Interval: 2 s (so it beeps every couple seconds while L2=ON) -
Turn your volume up and test
• SYS → AUDIO → Volume = 100% (or whatever you like)
• On the bench, short the pack-voltage input or pull it down in your FC so it reads <3.4 V.
• In MODEL → SPECIAL FUNCTIONS press “Expanded view” and watch your SF line turn green when Volt+ < 3.4.
• You should hear the beep.
– If you’d prefer the built-in voice alarm instead, you can skip the Logical Switch & SF entirely and go to:
MODEL → TELEMETRY → ALARMS → select “Volt” sensor → set “Critical < 3.4 V” → Action = “Voice” or “Beep.”That will read out “Battery critical” without any SF at all.
But if you want full control over the WAV and the delay/armed-only qualifier, the L1/L2 → SF route above is the way to go. Give it a try and let me know how it goes! 🚀
-
Other models, same or similar prompt