Okay, let's solve this problem step by step.
First, we need to address the likely typos in the units given:
- "diện tích 1260 cm³": Diện tích should be in square units, not cubic. We'll assume this is 1260 cm².
- "cảm ứng từ 20 ml": Magnetic field (cảm ứng từ) is measured in Tesla (T). "ml" is a unit of volume. We'll assume this is 20 milliTesla (mT).
Let's convert the units to the standard SI system:
- Area A = 1260 cm² = 1260 * (10⁻² m)² = 1260 * 10⁻⁴ m² = 0.126 m².
- Magnetic field B = 20 mT = 20 * 10⁻³ T = 0.02 T.
- Time t = 1 phút = 60 s.
Now, let's break down the questions.
Question 2: Suất điện động cực đại của máy phát
The maximum induced EMF (suất điện động cực đại), E₀, in a generator is given by the formula:
E₀ = N * B * A * ω
where:
- N is the number of turns in the stator coil.
- B is the magnetic field strength.
- A is the area of each turn.
- ω is the angular velocity of the rotor.
First, we need to find the frequency of the phao and then the frequency and angular velocity of the rotor.
- The phao oscillates 6 times in 10 s. So, the frequency of the phao is f_phao = 6 cycles / 10 s = 0.6 Hz.
- The rotor frequency (f_rotor) is 30 times the phao frequency: f_rotor = 30 * f_phao = 30 * 0.6 Hz = 18 Hz.
- The angular velocity ω is related to the rotor frequency by ω = 2πf_rotor. Using π = 3.14 as given: ω = 2 * 3.14 * 18 rad/s = 6.28 * 18 rad/s = 113.04 rad/s.
Now, we can calculate the maximum EMF E₀:
- N = 600
- B = 0.02 T
- A = 0.126 m²
- ω = 113.04 rad/s
E₀ = 600 * 0.02 * 0.126 * 113.04
E₀ = 12 * 0.126 * 113.04
E₀ = 1.512 * 113.04
E₀ ≈ 171.03648 V
Rounding the result to the nearest whole number (chữ số hàng đơn vị):
E₀ ≈ 171 V.
Câu 2. Suất điện động cực đại của máy phát khi đó là 171 Vold.
Question 3: Nhiệt lượng toả ra trên điện trở R trong 1 phút
When the generator is connected to a resistor R, the power dissipated as heat is given by P = V_rms² / R, where V_rms is the RMS voltage. The heat dissipated in time t is Q = P * t = (V_rms² / R) * t.
For a sinusoidal voltage, the RMS voltage is related to the peak voltage (E₀) by V_rms = E₀ / √2. In this case, V_rms is the RMS EMF generated by the machine.
Q = ( (E₀ / √2)² / R ) * t
Q = ( E₀² / 2R ) * t
We use the unrounded value of E₀ for calculation to maintain precision, and round the final result.
- E₀ ≈ 171.03648 V
- R = 100 Ω
- t = 60 s
Q = ( (171.03648)² / (2 * 100) ) * 60
Q = ( 29253.507 / 200 ) * 60
Q = 146.267535 * 60
Q ≈ 8776.0521 J
Rounding the result to the nearest whole number (chữ số hàng đơn vị):
Q ≈ 8776 J.
Câu 3. Nhiệt lượng toà ra trên điện trở R trong 1 phút là 8776 Jun.
Summary of Answers:
- Câu 2: Suất điện động cực đại của máy phát khi đó là 171 Vold.
- Câu 3: Nhiệt lượng toà ra trên điện trở R trong 1 phút là 8776 Jun.