What UK standard or regulation says about minimum one metre distance from buildings…

From a Chatbot Arena battleThe same person sent this prompt to two anonymous models at once. Compare it with Amazon Novaamazon-nova-experimental-chat-05-14’s answer.
  1. User

    What UK standard or regulation says about minimum one metre distance from buildings Regarding propane storage? Does IGEM mention it?

  2. MiniMax Assistant

    The UK regulations and standards regarding the minimum distance for propane (LPG) storage are as follows:

    1. Key Standard: IGEM/SR/25

    The primary reference is the Institution of Gas Engineers and Managers (IGEM) Standard SR/25, titled "Storage of LPG at Fixed Installations". This standard is widely recognized and adopted in the UK.

    • Part 1 (Domestic Installations):

      • Table 2 specifies separation distances for cylinder storage.
      • For small propane cylinders (e.g., typical domestic 3.9kg–15kg cylinders), the minimum distance from a building is 1 metre if the total storage capacity is ≤ 15kg.
      • Larger quantities or bulk tanks require greater separation (e.g., 3–5+ metres depending on capacity).
    • Part 2 (Non-Domestic/Industrial Installations):

      • Applies to larger storage systems. Separation distances depend on tank size and location (e.g., 3–15+ metres for bulk tanks).

    2. HSE Guidance

    The Health and Safety Executive (HSE) references IGEM/SR/25 in guidance such as:

    • HSG51 ("Storage of flammable liquids in tanks") and L56 ("Safety in the installation and use of gas systems").
    • These documents defer to IGEM standards for LPG-specific requirements.

    3. Regulatory Framework

    • The Dangerous Substances and Explosive Atmospheres Regulations 2002 (DSEAR):
      Requires risk assessments to ensure safe separation distances. IGEM/SR/25 provides the technical basis for compliance.
    • Building Regulations 2010 (Approved Document J):
      Indirectly references separation distances for combustion appliances but defers to IGEM for gas storage specifics.

    Summary:

    • Minimum 1 metre distance from buildings applies to small propane cylinders (≤ 15kg total capacity) under IGEM/SR/25 Part 1.
    • Larger installations follow IGEM/SR/25 Part 2 or HSE guidance.
    • Always consult the latest version of IGEM/SR/25 and local authority requirements for compliance.

    For precise calculations, use IGEM/SR/25 Part 1, Table 2 or Part 2, Table 5 for bulk storage.

Responses were produced in different, uncontrolled contexts (system prompts, settings, prior turns). This is not a benchmark.