Let's walk through the energy‐flow and moisture issues step by step. In the setup:
- Room A (evaporative chamber): Outside air at temperature T enters, contacts water, and picks up moisture. Because evaporation “uses” some of the air’s sensible heat (i.e. energy goes into evaporating water), the air’s temperature drops while its humidity increases.
- Room B: The cooled, humid air from Room A is delivered via a pipe. In Room B the air is passed over (or through) a “radiator” (a heat exchanger)—in other words, a device that heats the air before it is eventually exhausted back to the outside.
There are two “competing” effects here:
- Cool Air from Room A: When the cooler air enters Room B it would tend to lower the temperature there.
- Air Heating in the Radiator: The radiator (assuming it is supplied with a hotter fluid) warms the air as it passes by.
Now, let’s address your specific questions:
1. Would Room B cool because the air coming from Room A is at a lower temperature than Room B?
- In isolation: If you simply injected cooler air into Room B (without doing anything to warm it) then—assuming no compensating heating—the room temperature would tend to drop.
- However: In your system the incoming air is subsequently warmed by the radiator. So, if the radiator’s energy input is sufficient to bring the incoming air back to or above T, then the initial “cooling” from Room A is offset. The net effect on Room B will then depend on the balance of:
- The mass (or volumetric) flow of cool air coming in,
- The amount of heat added by the radiator, and
- Other heat losses or gains in Room B.
It is possible that an unchecked influx of cool air could cool Room B, but the idea of then heating it via the radiator indicates that the system has been designed so that the net energy delivered back to the room (by the radiator, and possibly also by latent heat if condensation occurs) keeps the space near the desired temperature T.
2. Would the air’s increase in temperature within the radiator cause condensation?
A key point about condensation:
- Condensation occurs when air is cooled below its dew point.
- Here, the air from Room A is humid and cool, so its dew point is relatively high.
- When the air passes over a warm radiator, its temperature is raised. In warming the air, the relative humidity actually decreases, meaning that the air becomes more “comfortable” (i.e. less likely to condense water out on the surfaces).
- However, if, for some reason, portions of the heat exchanger (radiator) are at a temperature lower than the dew point of that humid air, then local condensate could form on the radiator surfaces. But if the purpose of the radiator is to reheat the air, its surfaces are typically kept warm enough (by design) to avoid condensation.
So in general, the heating process itself tends not to cause condensation; rather, condensation is more an issue if humid air is cooled toward or below its dew point.
3. If there is condensation, would that warm Room B?
If condensation did occur on a surface in Room B (say on parts of the radiator), it would mean that water vapor is condensing into liquid water. The process of condensation releases latent heat (often on the order of 2,500–2,600 kJ/kg of water) into the immediate surroundings. This heat release would then warm the local air.
So, yes, condensation in Room B would add heat to the room. But—as noted above—the design goal for a radiator used as a heater is to warm the air, not to cool it; so one would normally try to avoid having surfaces at temperatures that drop below the dew point if the intention is to have controlled heating. (In some HVAC systems designed for “condensing operation” the latent heat release is actually an intentional benefit.)
4. Overall—would the radiator cool Room B, heat Room B, or neither?
- Without any intervention, the cooler, humid air coming from Room A would tend to lower the sensible temperature in Room B.
- But with the radiator actively adding heat: The radiator raises the temperature of the air passing through it. Even if some condensation were to occur (releasing latent heat), that is an additional warming effect.
- So, the net effect: The radiator is a heating device for Room B. Its purpose is to add sensible heat (and if condensation occurs, latent heat) such that the injected cool, humid air is returned to or above the desired room temperature T before being exhausted.
In other words, while the cooler air could temporarily cool the environment, the design of circulating it through a heat exchanger (radiator) means that its sensible—and, in the event of condensation, latent—heat is recovered (or added) to warm Room B. Thus, the radiator heats Room B rather than cooling it.
Summary Answer
- Although the air from Room A is cooler, if it were left unchecked it would cool Room B.
- However, in Room B the air is passed over a radiator that heats it; heating the air raises its temperature above the dew point so that condensation is generally avoided, and even if condensation occurs, the latent heat release warms the room.
- Therefore, the radiator in Room B functions as a heater (it warms the room), not as a cooler.