example of steel beam with torsion design AISC- SI units?
- User
example of steel beam with torsion design AISC- SI units?
Assistant
Here is an example of a steel beam design with torsion according to AISC (American Institute of Steel Construction) specifications, using SI units:
Problem Statement
Design a simply supported steel beam with a span of 6 meters, subjected to a uniformly distributed load of 10 kN/m and a concentrated torsional moment of 5 kN.m at mid-span. The beam is laterally supported at both ends. Use AISC specifications and SI units.
Given Data
- Span (L) = 6 m
- Uniformly distributed load (w) = 10 kN/m
- Concentrated torsional moment (T) = 5 kN.m
- Steel grade: A992 ( Fy = 345 MPa, Fu = 450 MPa)
- Beam section: W310x33 (a commonly used section in Canada and the US, with a depth of 313 mm, a flange width of 166 mm, and a weight of 33 kg/m)
Step 1: Calculate the factored loads
Using the AISC load combinations, we can calculate the factored loads:
- Factored uniformly distributed load (wu) = 1.2 x 10 kN/m = 12 kN/m
- Factored concentrated torsional moment (Tu) = 1.6 x 5 kN.m = 8 kN.m
Step 2: Calculate the bending moment and shear force
Using basic beam theory, we can calculate the bending moment and shear force:
- Maximum bending moment (M) = wu x L^2 / 8 = 12 kN/m x (6 m)^2 / 8 = 54 kN.m
- Maximum shear force (V) = wu x L / 2 = 12 kN/m x 6 m / 2 = 36 kN
Step 3: Check the beam section for bending
Using the AISC specifications, we can check the beam section for bending:
- Plastic section modulus (Zx) = 641 x 10^3 mm^3 (from AISC manual)
- Moment capacity (Mn) = Fy x Zx = 345 MPa x 641 x 10^3 mm^3 = 221 kN.m
- Factored moment resistance (Mr) = 0.9 x Mn = 0.9 x 221 kN.m = 199 kN.m
- Check: M / Mr = 54 kN.m / 199 kN.m = 0.27 < 1.0 (OK)
Step 4: Check the beam section for shear
Using the AISC specifications, we can check the beam section for shear:
- Shear area (Aw) = d x tw = 313 mm x 6.6 mm = 2068 mm^2 (from AISC manual)
- Shear capacity (Vn) = 0.6 x Fy x Aw = 0.6 x 345 MPa x 2068 mm^2 = 428 kN
- Factored shear resistance (Vr) = 0.9 x Vn = 0.9 x 428 kN = 385 kN
- Check: V / Vr = 36 kN / 385 kN = 0.09 < 1.0 (OK)
Step 5: Check the beam section for torsion
Using the AISC specifications, we can check the beam section for torsion:
- Torsional constant (J) = 134 x 10^3 mm^4 (from AISC manual)
- Torsional capacity (Tn) = (J / (L/2)) x (Fy / √3) = (134 x 10^3 mm^4 / (6 m / 2)) x (345 MPa / √3) = 12.3 kN.m
- Factored torsional resistance (Tr) = 0.9 x Tn = 0.9 x 12.3 kN.m = 11.1 kN.m
- Check: Tu / Tr = 8 kN.m / 11.1 kN.m = 0.72 < 1.0 (OK)
Step 6: Check the interaction between bending and torsion
Using the AISC specifications, we can check the interaction between bending and torsion:
- Check: (M / Mr)^2 + (Tu / Tr)^2 = (0.27)^2 + (0.72)^2 = 0.58 < 1.0 (OK)
The W310x33 beam section is adequate for the given loads, satisfying both bending and torsion requirements according to AISC specifications.
Keep in mind that this is a simplified example and actual design may require additional checks and considerations, such as deflection, lateral-torsional buckling, and local buckling. Consult the AISC specifications and relevant design codes for more detailed guidance.
Other models, same or similar prompt