You are absolutely right! My apologies for that oversight on the udld interval command. This highlights perfectly why direct interaction with the device and its error messages is crucial – theoretical knowledge can sometimes miss platform-specific nuances.
The error message Invalid interval. The interval value must be between 7000ms and 90000ms, specified as a multiple of 100, for example: 20, 100, 3000, or 90000. clearly tells us two things:
- The interval is specified in milliseconds.
- The minimum interval is 7000ms (7 seconds). My suggestion of
1 was indeed too low for the 6000 series.
- It also implies that
udld interval 7 (for example) would likely still be invalid, as it must be a "multiple of 100". So udld interval 7000 is the correct syntax for the fastest setting.
This also implies that the "aggressive" behavior (faster detection/shutdown) you find on some other CX models (like 6300/8320/8360) for UDLD might not be explicitly configurable or might function differently on the 6000 series, as it wasn't an option under udld mode.
Revised Best Practices for Aruba CX 6000 (1 Core, 4 Access, 4x1Gbps Copper LAGs)
Based on your interactive testing and the specific capabilities of the Aruba CX 6000, here's the refined best practice guide:
I. Link Aggregation (LAG) Optimization (Critical for Stability & Speed)
- LACP Fast Rate (Highly Recommended)
II. Unidirectional Link Detection (UDLD) (Enhanced Reliability)
-
Global UDLD Enablement
- Purpose: Activates the UDLD protocol globally on the switch.
- Command:
udld enable
- Apply on: Both Core and Access switches.
-
Per-Port UDLD Configuration (LAG Member Ports)
-
Errdisable Recovery for UDLD (Highly Recommended)
III. Spanning Tree Protocol (STP) Optimization (CRITICAL for "Phantom MACs")
This is the most likely solution for your "phantom MAC" issues.
-
STP Root Bridge Placement (Crucial for Network Stability)
-
STP Edge Ports (Essential for Access Ports)
-
STP Root Guard (Recommended for Access Switch Uplinks)
IV. General Management & Security Best Practices
-
Network Time Protocol (NTP)
-
Logging / Syslog
-
Secure Management (AAA)
-
VLAN Best Practices
Deployment Strategy:
Continue with your excellent strategy:
- Core Switch First: Apply the changes to the Core switch's LAGs.
- Access Switches One by One: Then, apply the changes to each Access switch sequentially, testing after each one.
- Access Port Changes: The STP edge port changes can generally be done any time on the access switches, as they primarily affect devices plugged into those specific ports.
By implementing these, you'll significantly improve the stability, performance, and manageability of your Aruba CX 6000 network. The STP changes are paramount for addressing the "phantom MAC" issue.