I have a Raspberry Pi Pico modified with an AP33772 USB controller that allows me to…
- User
I have a Raspberry Pi Pico modified with an AP33772 USB controller that allows me to pull specific voltages from a PPS enabled USB C power supply. The Pi also includes sensors for the USB C current and voltage, as well as the Pico's normal ADC interface. I would like to implement Constant Current lithium ion cell charging by manipulating the USB C output voltage to maintain the constant current.
Can you explain how to use a proportional control loop to implement the constant current charging stage? Feel free to use MicroPython psuedo-code.
Keep in mind that in my application, I will charge many different cells and I may use different power supplies. Any manual tuning dependent on specific hardware or cells will not be possible.
Assistant
Implementing Constant Current Charging with Proportional Control
A proportional control loop for constant current charging adjusts the USB-C output voltage based on the error between your target current and the measured current. Here's how to implement this without hardware-specific tuning:
Basic Proportional Control Approach
import time # Configuration TARGET_CURRENT = 1.0 # Amps - adjust based on cell capacity (typically 0.5C) SAMPLE_INTERVAL = 0.1 # seconds MAX_CELL_VOLTAGE = 4.2 # Maximum safe Li-ion voltage MIN_VOLTAGE_REQUEST = 3.7 # Starting voltage request MAX_VOLTAGE_REQUEST = 12.0 # Maximum voltage to request from PPS # Initial proportional gain - will be auto-tuned Kp = 0.5 def read_usb_current(): # Read current from your USB-C current sensor # Return value in Amps pass def read_cell_voltage(): # Read the battery cell voltage from ADC # Return value in Volts pass def set_pps_voltage(voltage): # Command AP33772 to request specific voltage from PPS # Implement appropriate safety limits here voltage = max(MIN_VOLTAGE_REQUEST, min(voltage, MAX_VOLTAGE_REQUEST)) # Send command to AP33772 pass def auto_tune_controller(): """Automatically determine appropriate Kp value based on system response""" print("Auto-tuning controller...") # Start with a safe voltage set_pps_voltage(MIN_VOLTAGE_REQUEST) time.sleep(0.5) # Let system stabilize # Measure initial current initial_current = read_usb_current() # Apply a small step change test_voltage = MIN_VOLTAGE_REQUEST + 0.3 set_pps_voltage(test_voltage) time.sleep(0.5) # Let system stabilize # Measure new current new_current = read_usb_current() # Calculate system gain (ΔI/ΔV) current_delta = new_current - initial_current voltage_delta = 0.3 # The step we applied if current_delta <= 0: # No positive response, use conservative value return 0.2 system_gain = current_delta / voltage_delta # Calculate Kp - lower gain for more stable response # Aim for slight underdamping kp = 0.3 / system_gain # Constrain to reasonable limits kp = max(0.05, min(kp, 1.0)) print(f"Auto-tuned Kp: {kp}") return kp def constant_current_charge(): """Main charging control loop""" global Kp # Auto-tune the controller Kp = auto_tune_controller() # Start with conservative voltage current_voltage = MIN_VOLTAGE_REQUEST set_pps_voltage(current_voltage) # Control loop variables last_adjustment_time = time.time() while True: # Read current values actual_current = read_usb_current() cell_voltage = read_cell_voltage() # Check if we should exit CC phase if cell_voltage >= MAX_CELL_VOLTAGE: print("Cell reached target voltage - ending CC phase") break # Calculate error error = TARGET_CURRENT - actual_current # Calculate voltage adjustment voltage_adjustment = Kp * error # Limit adjustment size for stability voltage_adjustment = max(-0.5, min(voltage_adjustment, 0.5)) # Calculate new voltage new_voltage = current_voltage + voltage_adjustment # Apply new voltage set_pps_voltage(new_voltage) current_voltage = new_voltage # Print debug info print(f"Current: {actual_current:.3f}A, Target: {TARGET_CURRENT:.3f}A") print(f"Adjustment: {voltage_adjustment:.3f}V, New voltage: {new_voltage:.3f}V") # Sleep until next iteration time.sleep(SAMPLE_INTERVAL) # Periodically re-tune if regulation is poor if abs(error) > 0.2 * TARGET_CURRENT and (time.time() - last_adjustment_time > 10): Kp = auto_tune_controller() last_adjustment_time = time.time()Key Improvements for Robustness
Here's an enhanced version with additional features for better adaptability:
def adaptive_constant_current_charge(): """Enhanced constant current charging with adaptation""" global Kp # Auto-tune the controller Kp = auto_tune_controller() # Start with conservative voltage current_voltage = MIN_VOLTAGE_REQUEST set_pps_voltage(current_voltage) # Control loop variables integral = 0 Ki = Kp * 0.1 # Integral gain previous_error = 0 last_adjustment_time = time.time() # Performance tracking error_history = [] while True: # Read current values actual_current = read_usb_current() cell_voltage = read_cell_voltage() # Check if we should exit CC phase if cell_voltage >= MAX_CELL_VOLTAGE: print("Cell reached target voltage - ending CC phase") break # Calculate error error = TARGET_CURRENT - actual_current error_history.append(abs(error)) # Only keep recent history if len(error_history) > 20: error_history.pop(0) # Calculate integral term with anti-windup integral += error * SAMPLE_INTERVAL integral = max(-1.0, min(integral, 1.0)) # Limit integral windup # Calculate adjustments p_term = Kp * error i_term = Ki * integral # Total adjustment voltage_adjustment = p_term + i_term # Limit adjustment size for stability voltage_adjustment = max(-0.5, min(voltage_adjustment, 0.5)) # Calculate new voltage new_voltage = current_voltage + voltage_adjustment # Apply new voltage set_pps_voltage(new_voltage) current_voltage = new_voltage # Evaluate control performance avg_error = sum(error_history) / len(error_history) # If regulation is poor, retune controller if (avg_error > 0.15 * TARGET_CURRENT and time.time() - last_adjustment_time > 10): print("Performance suboptimal, retuning controller...") Kp = auto_tune_controller() Ki = Kp * 0.1 integral = 0 last_adjustment_time = time.time() error_history = [] # Sleep until next iteration time.sleep(SAMPLE_INTERVAL)Implementation Notes:
-
Auto-tuning: The code automatically measures the system response to determine an appropriate Kp value, eliminating the need for manual tuning.
-
Adaptive Control: The enhanced version periodically evaluates performance and retunes if needed, accommodating different cells and power supplies.
-
Integral Action: Adding a small integral term helps eliminate steady-state error without needing perfect proportional tuning.
-
Safety Limits: The code includes voltage limits and adjustment rate limits to prevent dangerous conditions.
For best results, calculate TARGET_CURRENT based on the cell capacity (typically 0.5C for safe charging), and ensure your current and voltage measurements are properly filtered to reduce noise.
Would you like me to explain or break down any specific part of this code?
-