1 Introduction
This Function Test document provides comprehensive testing procedures and acceptance criteria for the hardware supplied for the Hong Kong Vessel Traffic Services System(HKVTSS). The testing covers 23 HPE ProLiant servers comprising three different configurations.
The purpose of the function test is to demonstrate that the system meets the requirements as described in the above mentioned contract.
2 Document Overview
This document specifies the environment, preparations, and procedures to be executed for the SAT. It includes the specification of simulated data (if applicable) and test environment.
2.1 Test set-up
The tests to be executed are described with the following items:
Item Description
Description A short description of the test. A reference to a requirement can be made.
Mode A description of the initial situation which is required to start the test.
Input Actual input(s) to be made to execute the test.
Result Required results after the execution of the input(s). When this result is met, the test is considered as successful. The related Preliminary System Proposal descriptions are considered as sufficiently demonstrated.
In case the item description and/or mode do not provide additional information, these items can be omitted.
Test Environment Requirements:
• Stable power supply (240V, 50Hz) with appropriate power distribution
• Network connectivity for iLO access
• Temperature controlled environment (20-25°C)
• Test workstation with web browser for iLO interface access
• KVM console or monitor/keyboard for initial setup
Required Test Equipment:
• Network cables (Cat6 or higher)
• Power cables (C13-BS-1363A UK/HK/SG standard)
• USB keyboard and mouse for initial configuration
• Monitor with appropriate video cables
2.2 Accuracy
Numeric values mentioned in this document are assumed to be accurate until the last decimal place; e.g. 10.1 NM means a value between 10.05 NM and 10.15 NM. Exceptions to this rule are explicitly mentioned.
For hardware specifications:
• Memory capacities are exact values (e.g., 32GB, 128GB, 256GB)
• Storage capacities follow manufacturer specifications
• Power ratings are nominal values
2.3 Duration of the tests
The table below gives the estimated time to execute the tests of this procedure.
Test Estimated time
[hours]
3.1 Visual Inspection
3.2 System Boot and iLO Verification
3.2.1 H1 Configuration (HPE ProLiant DL360 Gen11 Silver server)
- Boot Verification
- iLO Access and License
- Hardware Detection via iLO
- System Health via iLO
- Firmware and Driver Version Check
3.2.2 H3 Configuration (HPE ProLiant DL380 Gen11)
- Boot Verification
- iLO Access and License
- Hardware Detection via iLO
- System Health via iLO
- Firmware and Driver Version Check
3.2.3 H5 Configuration (HPE ProLiant DL360 Gen11 Gold server)
- Boot Verification
- iLO Access and License
- Hardware Detection via iLO
- System Health via iLO
- Firmware and Driver Version Check 1
14
5
4
Total 24
3 Hardware
Hardware Configuration Summary
Configuration MD reference Model Quantity
H1 1E HPE ProLiant DL360 Gen11 (Dual Xeon-Silver 4410Y) 14
H3 2F HPE ProLiant DL380 Gen11 (Dual Xeon-Silver 4410Y) 5
H5 1H HPE ProLiant DL360 Gen11 (Single Xeon-Gold 6434) 4
3.1 Visual Inspection
Item Description
Description Physical examination of all server hardware to verify structural integrity and identify any shipping damage or manufacturing defects by checking rack ears, server chassis, drive bays and power units for physical defects.
Mode Servers unpacked and positioned for inspection in controlled environment.
Input Visual and tactile inspection of each server unit according to the checklist below.
Result All servers pass visual inspection with no physical damage or defects identified.
Item Description Model / Part No. Qty Serial No. OK/NOK Comments
-
HPE ProLiant DL360 Gen11 Silver server HPE ProLiant DL360 sliver 14 SGHD2JJ7QY SGHD2JJ7R7 SGHD2JJ7RJ SGHD2JJ7RT SGHD2JJ7S3 SGHD2JJ7R1 SGHD2JJ7RB SGHD2JJ7RM SGHD2JJ7RX SGHD2JJ7S6 SGHD2JJ7R4 SGHD2JJ7RF SGHD2JJ7RQ SGHD2JJ7S0
-
HPE ProLiant DL380 Gen11 HPE ProLiant DL380 5 SGHD2JHVPP SGHD2JHVRD SGHD2JHVQ6 SGHD2JHVRZ SGHD2JHVQV
-
HPE ProLiant DL360 Gen11 Gold server HPE ProLiant DL360 Gold 4 SGHD2JHVN3 SGHD2JHVN4 SGHD2JHVN5 SGHD2JHVN8
3.2 System Boot and iLO Verification
3.2.1 H1 Configuration (HPE ProLiant DL360 Gen11 Silver server)
Server Model: H1 HPE ProLiant DL360 Gen11 Silver server
Serial Number: SGHD2JJ7QY
Test Item Expected Result Result (OK/NOK) Comments
Boot Verification
Power On Self Test (POST) Completes without errors
System Boot Can boot to BIOS/OS installer
Error Messages No critical errors during POST
iLO Access and License
iLO Web Interface Accessible via dedicated port
iLO Advanced License License activated
Hardware Detection via iLO
Processors 2x Intel Xeon-Silver 4410Y detected
Processor Cores 24 total cores (2x12)
Memory 128GB DDR5-4800 detected
Storage Controller HPE MR416i-o with 8GB cache
System Drives 2x 960GB SATA SSD detected
Network Adapter Broadcom BCM5719 4-port detected
Power Supplies 2x 800W PSUs online
System Health via iLO
Temperature Status All sensors within normal range
Fan Status All fans operational
Power Redundancy Both PSUs sharing load
Storage Battery Smart Storage Energy Pack (Status: OK)
Firmware and Driver Version Check
BIOS Firmware
iLO Firmware
RAID Controller Firmware
NIC Firmware
Server Model: H1 HPE ProLiant DL360 Gen11 Silver server
Serial Number: SGHD2JJ7R7
Same as the above form if they are same type
But I received comment:
Please create one test form for each server type to reduce the length of the SAT document and avoid the chance of inconsistencies between the sessions.
what does that mean?