Here’s a rough summary of indoor moisture‐generation rates for a typical home. Actual numbers will vary with activity level, appliance type, ventilation, water temperature, etc., but these figures will give you a ballpark for sizing dehumidifiers or ventilation systems.
| Source | Rate (moisture mass) | Notes / Typical “per event” |
|---|
| Occupants | | |
| – at rest (sleeping) | 30 – 40 g / h per person | ~0.7 L / day |
| – sedentary (office work) | 60 – 80 g / h per person | ~1.4 L / day |
| – light exercise | 100 – 150 g / h per person | |
| Cooking | | |
| – electric range | 300 – 500 g / h household | e.g. simmering, sautéing |
| – gas range | 500 – 900 g / h household | pilots + hot surfaces |
| – large‐boil (pasta pot) | 1.0 – 1.5 kg / h | brief “peak” moisture spikes |
| – dishwashing (hand) | 400 – 600 g / h | depends on water temperature, cover |
| Showering & Bathing | | |
| – continuous shower | ~0.5 L / min ≃ 30 kg / h | assumes ~5%–10% of flow (10 L/min) |
| – single 10 min shower | ~5 – 10 L per shower | evaporates into the room |
| – tub bath (filled 150 L) | ~3 – 5 L per bath | fraction of tub volume evaporates |
Total daily moisture for a four-person household with two showers and three cooked meals might look like:
• Occupants: 4 × 1.4 L/day = 5.6 L
• Cooking: ≃3 × 0.5 L = 1.5 L
• Dishwashing: ≃0.5 L
• Showers: 2 × 7 L = 14 L
→ ≈ 21.6 L/day of water vapor added to the indoor air
If you need to size a dehumidifier or calculate ventilation requirements, simply add up your own household’s estimated rates and compare against the capacity of your equipment (e.g. a 20 pint/day dehumidifier = ~9 L/day).
Key takeaways
- Even “passive” sources (people) contribute ~1–1.5 L/person · day.
- Active sources (steam cooking, showers) can easily dump 5–15 L in a single event.
- Good exhaust ventilation (range hood, bathroom fan) is essential to keep RH in check.
Hope this helps! Let me know if you need to drill down on any one source or scenario. 😊