    I'm installing a new residence hose bib. Should that be done with 3/4 inch or half inch supply line

  2. Assistant

    Go with 3/4 inch for the supply line to your new hose bib if possible.

    Here's why:

    1. Higher Flow Rate (Volume): A 3/4 inch pipe has a significantly larger internal diameter than a 1/2 inch pipe. This means it can deliver a much greater volume of water (Gallons Per Minute - GPM).
      • This is beneficial for tasks like running sprinklers, washing cars, or filling pools/large containers quickly.
    2. Less Pressure Drop: Over any significant distance, water flowing through a 1/2 inch pipe will experience more friction, leading to a greater pressure drop at the hose bib. A 3/4 inch line will maintain better pressure, especially if the run from your main water line to the bib is long.
    3. Future-Proofing: You might not need the extra flow now, but your needs could change. It's much easier to install the larger pipe now than to wish you had later.
    4. Minimal Cost Difference (Relatively): While 3/4 inch pipe and fittings are slightly more expensive than 1/2 inch, the difference is usually not substantial for a single hose bib installation, especially when considering the labor involved. The performance gain is well worth the small extra material cost.

    When might 1/2 inch be "acceptable" (but still not ideal)?

    • If the run is very short (e.g., just a few feet from a 3/4" or larger main line).
    • If you only ever intend to use it for very light tasks like watering a few potted plants.
    • If your entire house is plumbed with 1/2 inch and tapping into a larger line is not feasible (though even then, running 3/4" from the 1/2" tap-in point to the bib will still reduce pressure loss over that new segment).

    Recommendation:

    Even if your main water lines are 1/2 inch (less common in newer homes but possible in older ones or specific branches), running a 3/4 inch line to the new hose bib will still provide the least restriction for that segment of pipe. Always opt for 3/4 inch for a new hose bib supply line if you have the choice. You won't regret having better water flow.

    Don't forget other important aspects:

    • Frost-proof sillcock: If you live in an area with freezing temperatures.
    • Vacuum breaker/Backflow preventer: Usually required by code to prevent contamination of your water supply. Many modern sillcocks have these built-in.
    • Shut-off valve: Install an accessible shut-off valve on the new line inside the house for maintenance or winterization.
    • Proper support: Secure the pipe adequately.