/* main.c */
#include "main.h"
#include "mongoose.h"
#include "st25dv.h"
#include <stdio.h>
#include <string.h>
// Configuration
#define LISTENING_PORT "80"
#define MQTT_BROKER "mqtt://192.168.1.10:1883"
#define INFLUX_URL "http://192.168.1.10:8086"
#define GOLANG_API "http://192.168.1.10:8080/api/plc-data"
// PLC Data Structure
typedef struct {
float temperature;
uint16_t pressure;
uint16_t status;
uint8_t motor_running;
uint8_t alarm_active;
uint32_t timestamp;
char machine_id[32];
} PLCData_t;
static PLCData_t g_plcData = {0};
static struct mg_mgr g_mgr;
static struct mg_connection *g_mqtt_conn = NULL;
// Web Dashboard HTML
static const char *s_web_dashboard =
"<!DOCTYPE html>"
"<html><head>"
"<title>PLC Data Monitor</title>"
"<meta charset='utf-8'>"
"<meta name='viewport' content='width=device-width, initial-scale=1'>"
"<style>"
"body { font-family: Arial, sans-serif; margin: 20px; background: #f4f4f4; }"
".container { max-width: 800px; margin: 0 auto; background: white; padding: 20px; border-radius: 10px; box-shadow: 0 0 10px rgba(0,0,0,0.1); }"
".data-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 20px; margin-top: 20px; }"
".data-card { background: #f8f9fa; padding: 15px; border-radius: 5px; border-left: 4px solid #007bff; }"
".data-label { color: #666; font-size: 0.9em; }"
".data-value { font-size: 1.5em; font-weight: bold; color: #333; }"
".status-on { color: #28a745; }"
".status-off { color: #6c757d; }"
".alarm-active { color: #dc3545; }"
"</style>"
"<script>"
"function updateData() {"
" fetch('/api/data')"
" .then(response => response.json())"
" .then(data => {"
" document.getElementById('temperature').textContent = data.temperature.toFixed(1) + '°C';"
" document.getElementById('pressure').textContent = data.pressure + ' PSI';"
" document.getElementById('motor').textContent = data.motor_running ? 'RUNNING' : 'STOPPED';"
" document.getElementById('motor').className = data.motor_running ? 'status-on' : 'status-off';"
" document.getElementById('alarm').textContent = data.alarm_active ? 'ACTIVE' : 'OK';"
" document.getElementById('alarm').className = data.alarm_active ? 'alarm-active' : 'status-on';"
" document.getElementById('timestamp').textContent = new Date(data.timestamp * 1000).toLocaleString();"
" });"
"}"
"setInterval(updateData, 2000);"
"window.onload = updateData;"
"</script>"
"</head><body>"
"<div class='container'>"
"<h1>PLC Data Monitor - STM32 NFC Gateway</h1>"
"<div class='data-grid'>"
"<div class='data-card'><div class='data-label'>Temperature</div><div class='data-value' id='temperature'>--</div></div>"
"<div class='data-card'><div class='data-label'>Pressure</div><div class='data-value' id='pressure'>--</div></div>"
"<div class='data-card'><div class='data-label'>Motor Status</div><div class='data-value' id='motor'>--</div></div>"
"<div class='data-card'><div class='data-label'>Alarm Status</div><div class='data-value' id='alarm'>--</div></div>"
"</div>"
"<div style='margin-top: 20px; text-align: center; color: #666;'>"
"<small>Last Update: <span id='timestamp'>--</span></small>"
"</div>"
"</div>"
"</body></html>";
// HTTP Event Handler
static void http_handler(struct mg_connection *c, int ev, void *ev_data, void *fn_data) {
if (ev == MG_EV_HTTP_MSG) {
struct mg_http_message *hm = (struct mg_http_message *) ev_data;
if (mg_http_match_uri(hm, "/")) {
// Serve dashboard
mg_http_reply(c, 200, "Content-Type: text/html\r\n", "%s", s_web_dashboard);
}
else if (mg_http_match_uri(hm, "/api/data")) {
// Serve current PLC data as JSON
char json[256];
snprintf(json, sizeof(json),
"{\"temperature\":%.2f,\"pressure\":%d,\"status\":%d,"
"\"motor_running\":%s,\"alarm_active\":%s,\"timestamp\":%lu,"
"\"machine_id\":\"%s\"}",
g_plcData.temperature, g_plcData.pressure, g_plcData.status,
g_plcData.motor_running ? "true" : "false",
g_plcData.alarm_active ? "true" : "false",
g_plcData.timestamp, g_plcData.machine_id);
mg_http_reply(c, 200, "Content-Type: application/json\r\n"
"Access-Control-Allow-Origin: *\r\n",
"%s", json);
}
else {
mg_http_reply(c, 404, "", "Not Found");
}
}
}
// MQTT Event Handler
static void mqtt_handler(struct mg_connection *c, int ev, void *ev_data, void *fn_data) {
if (ev == MG_EV_MQTT_OPEN) {
// Subscribe to PLC data topic
struct mg_mqtt_opts opts = {0};
opts.topic = mg_str("plc/data");
opts.qos = 1;
mg_mqtt_sub(c, &opts);
printf("MQTT: Subscribed to plc/data\n");
}
else if (ev == MG_EV_MQTT_MSG) {
struct mg_mqtt_message *mm = (struct mg_mqtt_message *) ev_data;
// Parse JSON data from Golang service
struct mg_str json = mm->data;
double temperature = mg_json_get_num(json, "$.temperature", 0);
int pressure = (int)mg_json_get_num(json, "$.pressure", 0);
int status = (int)mg_json_get_num(json, "$.status", 0);
bool motor = mg_json_get_bool(json, "$.motor_running", false);
bool alarm = mg_json_get_bool(json, "$.alarm_active", false);
// Update global data
g_plcData.temperature = (float)temperature;
g_plcData.pressure = pressure;
g_plcData.status = status;
g_plcData.motor_running = motor ? 1 : 0;
g_plcData.alarm_active = alarm ? 1 : 0;
g_plcData.timestamp = time(NULL);
// Update NFC tag
UpdateNFCTag(&g_plcData);
printf("MQTT: Data updated - Temp:%.2f, Pressure:%d\n",
g_plcData.temperature, g_plcData.pressure);
}
}
// HTTP Client - Fetch from Golang API
static void fetch_plc_data(struct mg_mgr *mgr) {
struct mg_connection *c = mg_http_connect(mgr, GOLANG_API, NULL, NULL);
if (c != NULL) {
mg_printf(c, "GET /api/plc-data HTTP/1.1\r\n"
"Host: 192.168.1.10\r\n"
"Accept: application/json\r\n\r\n");
}
}
// Timer function for periodic data fetching
static void timer_fn(void *arg) {
struct mg_mgr *mgr = (struct mg_mgr *) arg;
// Option 1: Fetch via HTTP from Golang service
// fetch_plc_data(mgr);
// Option 2: Direct Modbus query (if needed)
// modbus_fetch_data(mgr);
}
// Update NFC Tag with current data
void UpdateNFCTag(PLCData_t *data) {
uint8_t ndef_buffer[256];
uint16_t ndef_len;
char text_data[200];
// Format data for NFC
snprintf(text_data, sizeof(text_data),
"PLC Monitor\n"
"===========\n"
"Machine: %s\n"
"Temp: %.1f°C\n"
"Pressure: %d PSI\n"
"Motor: %s\n"
"Alarm: %s\n"
"Time: %s\n"
"\nWeb: http://%s",
data->machine_id,
data->temperature,
data->pressure,
data->motor_running ? "Running" : "Stopped",
data->alarm_active ? "ACTIVE!" : "OK",
ctime(&data->timestamp),
GetIPAddress());
// Create NDEF message
NDEF_Text_info_t textInfo = {
.encoding = NDEF_TEXT_UTF8,
.language = "en",
};
strcpy(textInfo.text, text_data);
// Write to NFC tag
if (NDEF_WriteText(&textInfo, ndef_buffer, &ndef_len) == NDEF_OK) {
ST25DV_WriteData(0, ndef_buffer, ndef_len);
printf("NFC: Tag updated successfully\n");
}
}
// Initialize Mongoose networking
void InitializeNetworking(void) {
mg_mgr_init(&g_mgr);
mg_log_set_level(MG_LL_DEBUG);
// Start HTTP server with dashboard
struct mg_connection *http_conn = mg_http_listen(&g_mgr, LISTENING_PORT,
http_handler, NULL);
if (http_conn == NULL) {
printf("Failed to start HTTP server\n");
return;
}
printf("HTTP server started on port %s\n", LISTENING_PORT);
// Connect to MQTT broker
struct mg_mqtt_opts mqtt_opts = {
.client_id = mg_str("stm32-nfc-gateway"),
.qos = 1,
.retain = false,
.keepalive = 60
};
g_mqtt_conn = mg_mqtt_connect(&g_mgr, MQTT_BROKER, &mqtt_opts,
mqtt_handler, NULL);
if (g_mqtt_conn == NULL) {
printf("Failed to connect to MQTT broker\n");
}
// Set up periodic timer (5 seconds)
mg_timer_add(&g_mgr, 5000, MG_TIMER_REPEAT, timer_fn, &g_mgr);
}
// Main STM32 task for Mongoose
void MongooseTask(void *pvParameters) {
InitializeNetworking();
// Main event loop
while (1) {
mg_mgr_poll(&g_mgr, 100);
vTaskDelay(pdMS_TO_TICKS(10));
}
}
int main(void) {
// STM32 initialization
HAL_Init();
SystemClock_Config();
MX_GPIO_Init();
MX_I2C1_Init(); // For NFC
// Initialize Ethernet
MX_LWIP_Init();
// Initialize NFC
ST25DV_Init();
// Set initial machine ID
strcpy(g_plcData.machine_id, "PROD_LINE_01");
// Create FreeRTOS task for Mongoose
xTaskCreate(MongooseTask, "Mongoose", 4096, NULL, 5, NULL);
// Start FreeRTOS scheduler
vTaskStartScheduler();
while (1) {
// Should never reach here
}
}