complete the complexe pipeline section. I want to say that stopping the motor, measuring…
- User
complete the complexe pipeline section. I want to say that stopping the motor, measuring the values with adc ans stuff, get the speed, and integrate for position, all of this while doing closed loop position control, is not trivial with 18 motors simultaneously on 1 MCU. I don't want bullet points in this parts, as it is already part of a begin itemise. Also mention that some of the steps, like adc step can be done with specialised hardware, but add complexity,, cannot drive all motors at same time, so on so on \subsection{Selection of the control method} The first step going into this project was to decide which sensorless control method to use, as all the hardware and software will be entirely dependent of this choice. There exist multiple techniques to control brushed DC motor in position without encoders, but very little of them are actually suited for our application. Let's see a few of them in more detail to understand: \subsubsection{Back-EMF Sensing} This is perhaps the most common sensorless technique for speed control. It relies on the principle that a spinning motor also acts as a generator, producing a voltage proportional to its rotational speed, known as Back-Electromotive Force (Back-EMF). By briefly interrupting the PWM drive signal and measuring the voltage across the motor terminals during this "off" period, one can estimate the motor's speed. To get position, this speed signal must be integrated over time. However, this method presents several critical flaws for our application: \begin{itemize} \item \textbf{Struggles at low RPM and impossible at standstill:} The Back-EMF signal is directly proportional to speed. At very low speeds, the signal becomes very noisy and is difficult to measure accurately. At a complete standstill, which is essential for holding a position, the Back-EMF is zero, making position sensing impossible. \item \textbf{Integral drift:} Relying on the integration of a noisy speed measurement to estimate position is inherently unstable. Any small, constant error in the speed measurement will accumulate over time, causing the calculated position to drift indefinitely, even if the motor is perfectly still. \end{itemize} \item \textbf{Complex pipeline:} Given that our primary goal is precise position control, especially holding a static position, the inability to function at standstill makes Back-EMF sensing fundamentally unsuitable.
Other models, same or similar prompt
Responses were produced in different, uncontrolled contexts (system prompts, settings, prior turns). This is not a benchmark.