When an BLDC motor operates at a very low RPM under a high load, with the effective power lower than its full rated power, several key factors come into play regarding torque and motor behavior:
1. Torque-Speed Relationship
- Torque is High at Low Speed: BLDC motors exhibit a torque-speed curve where torque is highest at 0 RPM (stall) and decreases as speed increases. At very low RPM, the motor can indeed deliver significant torque, even under heavy loads.
- Power Equation: Power ((P)) is the product of torque ((T)) and speed ((N)):
[
P = T \times N
]
At low (N), even with high (T), the power output (P) may remain below the motor’s rated power (which is typically specified at an optimal operating point on the torque-speed curve).
2. Why Power Might Be Below Rated
- Thermal and Current Limits:
- The motor’s rated power is often defined at a point where the motor can operate continuously without overheating. At stall (0 RPM), torque is maximum, but power is zero. However, stall current is extremely high ((I_{\text{stall}} = V_{\text{supply}} / R_{\text{motor}})), leading to resistive losses ((I^2R)) that can overheat the motor even if power (P) is low.
- Most controllers limit current to protect the motor from exceeding its thermal or voltage limits, which may prevent delivering the theoretical maximum torque.
- Controller and Power Supply Constraints:
- The controller might restrict current to avoid damaging the motor or battery.
- The power supply (e.g., battery) must provide sufficient voltage/current to drive the required current through the motor’s windings. If voltage is insufficient, torque will be limited.
3. Maximizing Torque
To achieve the maximum possible torque under these conditions:
- Adjust Controller Settings:
- Increase the current limit on the controller to allow higher current flow, but do not exceed the motor’s rated continuous current (check datasheet).
- Ensure the controller’s firmware allows operation near stall conditions (some controllers have "torque mode" for this purpose).
- Ensure Adequate Cooling:
- Even at low power, resistive losses ((I^2R)) at high current can cause overheating. Use forced air cooling or a heatsink if necessary.
- Check Power Supply Capacity:
- Verify the battery or power supply can deliver the required voltage and current without voltage sag. A weak power source may limit torque.
- Avoid Prolonged Stall:
- While the motor can briefly deliver stall torque, continuous operation at stall will eventually overheat it. Use only for short intervals.
4. Potential Risks
- Thermal Damage: Exceeding the motor’s current rating (even briefly) can degrade windings or magnets.
- Battery Drain: High current draws can rapidly deplete batteries or cause voltage drops.
- Controller Damage: Some controllers may shut down or fail if current limits are exceeded.
Practical Recommendations
- Use a Torque-Mode Controller: These prioritize current (torque) over speed, allowing maximum torque delivery under load.
- Monitor Temperature: Use thermal sensors or observe for overheating.
- Optimize for Short-Duration Loads: If the application requires sustained high torque, consider a motor with a higher continuous torque rating or a gearbox for mechanical advantage.
Summary
At very low RPM under high load, the BLDC motor can deliver substantial torque, but practical limits (controller settings, thermal constraints, and power supply) may restrict it. To maximize torque:
- Increase the controller’s current limit (within motor specs).
- Ensure the power supply can handle the load.
- Avoid prolonged stall conditions to prevent overheating.
The motor’s theoretical maximum torque is determined by its current capacity, while the practical maximum depends on the system’s thermal and electrical limitations.