Consider the heat equation on the plane. Suppose there's a heat source, it keeps (0,0) at temperature T. All other points initially have zero temperature. Let the system evolve, ant then measure the temperature at (r, 0) at time t. What's it, asymptotically, when r and t are large?
Assistant
Other models, same or similar prompt
Responses were produced in different, uncontrolled contexts (system prompts, settings, prior turns). This is not a benchmark.
This problem describes the heat equation on an infinite plane with a continuous heat source at the origin (0,0). The phrase "it keeps (0,0) at temperature T" is ambiguous for a single point, as a true point source in 2D would lead to an infinite temperature at the origin. However, this phrasing is likely intended to parameterize the strength of the heat source.
Let's assume the heat source at the origin emits heat at a constant rate Q (power per unit length in 2D, as it's a 2D problem). The heat equation with this source is:
∂t∂u=k∇2u+ρcpQδ(x)
where u(x,t) is the temperature, k=K/(ρcp) is the thermal diffusivity (K is thermal conductivity, ρ is density, cp is specific heat capacity), and δ(x) is the 2D Dirac delta function at the origin. The initial condition is u(x,0)=0 for x=(0,0).
The solution for a continuous point source Qδ(x) (that starts at t=0) is given by integrating the fundamental solution of the heat equation over time:
u(x,
where is the fundamental solution in 2D:
Substituting and setting , we get:
Let . Then . When , . When , .
This integral is the definition of the Exponential Integral function .
So, with , the temperature at at time is:
The phrase "it keeps (0,0) at temperature T" is generally problematic for a point source as . It is usually assumed that here sets the scale for , perhaps for some constant with appropriate units, or that it is an idealized representation of a source in a small region. We will express the answer in terms of , assuming is proportional to .
Now, let's analyze the asymptotic behavior when r and t are large. Let z=4ktr.
Case 1: r is much larger than kt (i.e., z→)
This corresponds to points very far from the origin, or times too early for the heat to have diffused significantly to that point.
For large , the asymptotic expansion of is .
In this regime, the temperature drops rapidly with distance and time due to the exponential term, as the heat pulse has not fully reached the point .
The question asks for the temperature asymptotically when r and t are large, without specifying their relative magnitudes. Therefore, both cases describe the asymptotic behavior depending on the ratio r2/(4kt).
In summary:
Let k be thermal diffusivity, K be thermal conductivity, and Q be the constant heat power emitted by the source (per unit length in 2D).
The temperature u(r,t) at (r,0) at time t is given by:
where is the Exponential Integral function.
Asymptotically when r and t are large:
If r2/(4kt)→∞ (i.e., r grows faster than t):
User
I don't understand one thing, when you integrated the heat at x for t' from 0 to t -- does it correspond to some "collected heat" at this point? wouldn't it affect anything if we collect it there? Feel free to correct me, I understand that I am not good at physics :(
Assistant
That's a very good question, and it touches on a fundamental concept in solving linear partial differential equations like the heat equation! Don't worry, these concepts can be tricky at first.
Let's break down what that integral means:
The instantaneous point source (the "building block"):
The fundamental solution, G(x,t−t′), represents the temperature distribution at point x and time t due to a of heat released at the origin at an earlier time . Imagine you drop a small, very hot pebble into a large, cold lake at time . The fundamental solution describes how the temperature spreads out from that pebble over time.
User
Thank you for the clear explanation! I understood your solution. And now goes the following question, which was originally the motivation: what about the same situation on the hyperbolic plane?
Assistant
The problem asks for the temperature distribution on the hyperbolic plane at a point (r,0) at time t, given a continuous heat source at the origin (0,0) that effectively starts at t=0 and keeps the origin at "temperature T" (which we interpret as a constant heat source strength ). All other points are initially at zero temperature. We are interested in the asymptotic behavior for large and .
Case 2: r is much smaller than kt (i.e., z→0)
This corresponds to points that are relatively close to the origin, after a long time, so heat has diffused well past them.
For small z, the asymptotic expansion of E1(z) is E1(z)∼−γ−ln(z), where γ≈0.57721 is the Euler-Mascheroni constant.
u(r,t)∼4πKQ(u(r,t)∼4πKQ(
In this regime, the temperature grows logarithmically with time and decays logarithmically with distance from the source. This is characteristic of 2D diffusion from a continuous source, where a true steady state would be logarithmic.
u(r,t)=4πKQE1(4ktr2)
E1(z)
u(r,t)∼πKr2Qte−r2/(4kt)
If r2/(4kt)→0 (i.e., t grows faster than r2):
u(r,t)∼4πKQ(ln(r
where γ is the Euler-Mascheroni constant.
single, instantaneous pulse
t′
t′
The continuous heat source:
Your problem states there's a heat source at (0,0) that continuously keeps emitting heat starting from t=0. This is not a single pulse of heat; it's like a tiny heater that's always on.
Building the continuous solution from instantaneous ones (Superposition):
Because the heat equation is a linear partial differential equation, we can use the principle of superposition. This means that if you have multiple heat sources (or a source that acts over time), the total temperature at any point and time is simply the sum of the temperatures caused by each individual source event.
So, imagine the continuous heat source at (0,0) as an infinite series of tiny, instantaneous heat pulses, each released at a slightly different time t′.
At time t′=0, a tiny pulse dQ0 is released.
At time t′=δt′, another tiny pulse dQ1 is released.
...and so on, up to the current time t.
Each of these tiny pulses, dQ, released at time t′, contributes to the temperature at (r,0) at the current time t. The "age" of that particular pulse is . So, the contribution of the pulse released at is proportional to .
The integral:
u(r,t)=∫0t
is essentially (integrating) the temperature contributions from these tiny heat pulses that have been emitted from the origin between and the current time .
It's not "collecting heat" at (r,0) in the sense of storing it there. Temperature is an intensive property (like density or pressure), not an extensive one (like total energy or mass). The integral is calculating the total temperature at (r,0) at time t resulting from the continuous injection of heat at the origin and its subsequent diffusion through the medium. The heat flows through the point (r,0), raising its temperature as it passes.
Think of it like this:
If you have a continuously dripping faucet (the heat source) filling a bucket (the plane), the water level (temperature) at any given moment is the sum of the contributions from every single drop that has fallen since the faucet started dripping. You're not "collecting" the water at the bucket's rim; you're measuring the total water level in the bucket.
In the heat equation, the k∇2u term explicitly describes how heat diffuses and spreads out. The integral reflects how the continuous input of heat at the origin causes a propagating temperature field across the plane. The temperature you measure at (r,0) at time t is the current thermal state of that specific point, which is the result of all the heat that has arrived there (and passed through) from the origin up to that moment.
Q
r
t
The heat equation on a general Riemannian manifold is given by:
∂t∂u=kΔLBu+S
where u(x,t) is the temperature, k is the thermal diffusivity, ΔLB is the Laplace-Beltrami operator, and S is the source term. For a point source at the origin, S=ρcpQδ(r), where Q is the power of the source per unit "length" (in 2D), ρ is density, and cp is specific heat capacity. For simplicity, we can absorb Q/(ρcp) into a constant factor that multiplies the Green's function.
For a rotationally symmetric temperature distribution u(r,t) on the hyperbolic plane H2 with constant negative curvature (let's assume −1 for simplicity, as it can be scaled by k or r), the Laplace-Beltrami operator simplifies to:
ΔLBu=sinhr
where r is the hyperbolic distance from the origin.
The solution for a continuous point source Qδ(r) is obtained by integrating the fundamental solution (heat kernel) of the heat equation over time:
u(r,t)=ρcpQ∫0tG(r,s)ds
where G(r,s) is the heat kernel for an instantaneous source at time s=0.
The heat kernel on the hyperbolic plane H2 (with curvature −1, and k=1 for brevity in notation, k will be reinserted later) has a known asymptotic form. For small s (i.e., short times after the source fires), the heat kernel is approximated by a Gaussian similar to the Euclidean case, but corrected by the hyperbolic geometry:
G(r,s)≈4πs1e
This approximation is valid for small s (or small r relative to s). While this is an approximation, for the purpose of the continuous integral from s=0, the 1/s singularity and the Gaussian exponential are crucial, and the sinhrr term can be treated as a constant for s-integration as it only depends on r.
Substituting this into the integral for u(r,t):
u(r,t)≈ρcpQ∫0t4πs1e−r2/(4ks)sinhrrds
(Re-inserting k into the exponent for general thermal diffusivity).
We can pull out the terms that do not depend on s:
u(r,t)=4πρcp
Let K=kρcp be the thermal conductivity.
The integral ∫0ts1e is related to the Exponential Integral function E1(z)=∫z∞.
Let τ=4ksr2. Then s=4kτr2, and ds=−4kτ2r2.
When s=0, τ→∞. When s=t, τ=4ktr2.
So the integral becomes:
∫
Thus, the temperature at (r,0) at time t on the hyperbolic plane is approximately:
u(r,t)=4πKQ
Now we need to analyze the asymptotic behavior when r and t are large. Let z=4ktr2.
The function sinhrr depends on the hyperbolic geometry. For large r, sinhr≈2er. So sinhrr≈e.
We distinguish two cases based on the relative magnitude of r and t:
Case 1: r is much larger than kt (i.e., z=4ktr2→∞)
This means the heat front has not yet significantly reached the point (r,0).
For large z, the asymptotic expansion of E1(z) is E1(z)∼ze−z.
Substituting this and the large r approximation for sinhrr:
u(r,t)∼4πKQu(r,t)∼4πKQu(r,t)∼πKrer
Compared to the Euclidean case, there's an additional exponential decay factor e−r in the denominator, which signifies that heat spreads much faster into the exponentially growing area of hyperbolic space, leading to a much sharper temperature drop with distance.
Case 2: t is much larger than r2/k (i.e., z=4k)
This corresponds to the long-time behavior where heat has diffused well past the point .
For small , the asymptotic expansion of is , where is the Euler-Mascheroni constant.
Substituting this and the large approximation for :
In this long-time regime, the temperature still exhibits a logarithmic growth with time (due to the continuous source), but it decays exponentially with distance ( factor). This is a stark difference from the Euclidean case, where the decay with distance was logarithmic (), and the dependence on is absorbed into the term. The exponential decay in on the hyperbolic plane is a direct consequence of the exponential growth of area in hyperbolic space.
In summary, for large r and t:
u(r,t)≈4πKQsinhrrE1(4ktr2)
where k is thermal diffusivity and K is thermal conductivity.
Asymptotically:
If r2/(4kt)≫1:
u(r,t)∼πKrer2Qkte−r2/(4k
If r2/(4kt)≪1:
u(r
where is the Euler-Mascheroni constant.