I have a double sink. The larger sink drains directly down to the p-trap. The smaller…

From a Chatbot Arena battleThe same person sent this prompt to two anonymous models at once. Compare it with Claudeclaude-opus-4-20250514-thinking-16k’s answer.
  1. User

    I have a double sink. The larger sink drains directly down to the p-trap. The smaller sink has a waste arm that connects across to pipe going down from the large sink. When water runs down the large sink, the smaller sink makes very loud water trickling sounds. It might be gurgling, but no water is coming up and everything drains fine. It's almost as though the second sink acts as an amplifier of drip sounds.

    If I plug the smaller sink, then the noise goes away. Similarly, when water runs down the smaller sink, there is no noise. Water seems to drain quickly from both sinks -- I've checked by filling them with water and then letting it run out. I've also checked the vent on the roof and did not see any blockage. Finally, I've checked the slopes of the waste arm and trap arm and both are correct at 1/4 inch per foot.

    Why might this noise be occuring?

  2. Assistant

    What you’re hearing is almost certainly the plumbing “talking” to itself while the large bowl is trying to breathe.

    How the double-bowl kitchen sink is normally piped
    • Each bowl should empty into a short horizontal “continuous-waste” pipe.
    • That pipe drops into ONE common P-trap.
    • Immediately downstream of (or sometimes in line with) that trap, a vent allows air to get in and out of the system so the water can fall freely without creating suction or back-pressure.

    What’s happening in yours

    1. The big bowl dumps a slug of water straight down its tailpiece.
    2. That falling column of water pushes the air that was in the pipe out of its way.
    3. The vent stack is supposed to supply/relieve that air, but the shortest, easiest path turns out to be the horizontal arm that goes over to the small bowl.
    4. Air rushes across the water sitting in the small bowl’s trap and you hear:
      – trickling/“waterfall” sounds as the air skims a little water off the trap weir, and
      – a low gurgle because the sink basin above is acting like the body of a guitar, amplifying the noise.
    5. When you drop the stopper in the little bowl, that air path is sealed, the vent stack has to do all the work, and the noise stops—exactly what you’ve observed.

    Why isn’t it doing it when the small bowl drains?
    The small bowl’s tailpiece is shorter and the flow is usually slower, so the volume of displaced air is smaller and what air is needed can get through the trap/vent without any drama.

    Is something “wrong”?
    • Functionally, nothing is clogged and both traps are still holding water, so you’re not hurting anything.
    • Code-wise it suggests one of two things:

    1. The vent tie-in is a little too far away or undersized, or
    2. The cross-connection (the T that joins the bowls) doesn’t have a baffle, so the air looks for the path of least resistance—through the other sink.

    Ways to quiet it down (pick one that fits your ambition level)

    1. Live with it. Completely harmless, just noisy.
    2. Replace the center Tee with a “baffle tee” or a kit that has an internal partition for double bowls. The baffle forces each bowl to send air/water straight up/down instead of across.
    3. Add a stubby air-admittance valve (AAV) on the horizontal arm of the small bowl. That gives the system a dedicated place to pull air, sparing the sink opening itself.
    4. Re-pipe so both bowls enter the trap on a true horizontal continuous-waste, then drop into the trap, then into the vented drain line within the 4–5 ft (1¼ × pipe-diameter) limit your code demands.
    5. Confirm the vent stack is really clear all the way—not just at the roof opening—if you haven’t run a snake or camera down it before.

    Bottom line
    The noise is simply air being sucked through the little bowl’s trap because that’s the easiest way for the big bowl to get rid of or pull in air while it drains. Block the air path (stopper), improve the venting path (baffle, AAV, or move the vent), and the “amplified drip” disappears.