The determination of salinity in crude oil is typically performed to assess the concentration of dissolved salts, primarily sodium chloride (NaCl), which can affect refining processes and equipment. Below is a detailed, step-by-step methodology based on the ASTM D3230 standard (Electrometric Method), the most widely used approach:
Method: ASTM D3230 - Standard Test Method for Salts in Crude Oil (Electrometric Method)
Principle
The method measures chloride ions (Cl⁻) in crude oil using a chloride ion-selective electrode. Results are converted to sodium chloride (NaCl) equivalent.
Equipment/Supplies
- Ion-selective electrode (Cl⁻) and reference electrode (or a combination electrode).
- Voltmeter with millivolt (mV) resolution.
- Solvent: 50% xylene + 50% isopropyl alcohol (by volume).
- Standard NaCl solutions (e.g., 0.1, 1.0, 10 g/L NaCl in deionized water).
- Magnetic stirrer and stir bar.
- Sample containers, syringes, and analytical balance.
Procedure
-
Sample Preparation
- Sampling: Collect a representative crude oil sample (free of water and sediments if possible).
- Dissolution:
- Weigh 1.0 g of crude oil into a 100 mL volumetric flask.
- Add ~50 mL of solvent (xylene/isopropyl alcohol mix) and swirl to dissolve the oil.
- Dilute to the mark with solvent and mix thoroughly.
-
Calibration
- Prepare standard NaCl solutions (e.g., 0.1, 1.0, 10 g/L).
- Immerse the electrodes in each standard, stir gently, and record the mV reading after stabilization.
- Plot a calibration curve: mV vs. log[Cl⁻ concentration].
-
Measurement
- Place the electrode in the crude oil solution, stir, and record the mV value once stable.
- Use the calibration curve to determine the chloride concentration (mg/L Cl⁻).
-
Calculation
- Convert Cl⁻ to NaCl equivalent:
[
\text{NaCl (mg/L)} = \text{Cl⁻ (mg/L)} \times \frac{\text{MW NaCl}}{\text{MW Cl⁻}} = \text{Cl⁻} \times 1.648
]
- Report salinity as mg NaCl per kg of crude oil or pounds per thousand barrels (ptb).
[
\text{Salinity (ptb)} = \frac{\text{NaCl (mg/L)} \times \text{sample volume (L)}}{\text{sample mass (kg)} \times 453.6} \times 1000
]
Key Considerations
- Units: Salinity is often reported in:
- mg NaCl/kg oil (parts per million, ppm).
- lb/1000 bbl (common in industry; 1 ptb ≈ 2.85 ppm).
- Interferences: Other chloride salts (e.g., CaCl₂, MgCl₂) contribute to Cl⁻ but are reported as NaCl equivalent.
- Limitations: The method assumes all Cl⁻ is from NaCl; organic chlorides (e.g., in chlorinated solvents) may skew results.
Alternative Methods
- Conductivity Measurement:
- Measure conductivity of the crude oil/water emulsion. Requires correlation between conductivity and salinity.
- Gravimetric Analysis:
- Precipitate salts (e.g., AgCl), filter, dry, and weigh. Less common due to complexity.
- Produced Water Analysis:
- If crude oil is emulsified with water, separate the phases and measure salinity in the water phase (e.g., using a hydrometer or refractometer).
Summary
The ASTM D3230 electrometric method is the industry standard for determining crude oil salinity. It provides rapid, reliable results by measuring chloride ions and converting them to NaCl equivalent. Always follow safety protocols (e.g., solvent handling) and validate results with standards.