*Concentration Factor is the ratio of incoming source water to waste water,
indicating how many times the salt concentration is multiplied in the drain line.
You're right - the models are giving slightly different results. Let me analyze why:
Simple RO Model:
Output Permeate Conductivity: 280.0 µS/cm
Retentate Conductivity: 2,800.0 µS/cm
System 1:
Product Conductivity: 253.9 µS/cm
Drain Conductivity: 2865.3 µS/cm
The difference is about 9.3% for the permeate conductivity. Let's examine the mathematical approaches in both models to find the source of this discrepancy:
Key Difference: Treatment of the Recycle Loop
The main difference is in how the two models handle the recycle loop:
Simple RO Model: Uses a direct steady-state equation that assumes perfect mixing in the retentate loop.
System 1: Explicitly models the recycle flow and uses a more detailed mass balance that accounts for the specific recirculation path.
The System 1 equation is more complex because it explicitly accounts for:
The fixed RO feed flow (4000 ml/min)
The recycle flow (3300 ml/min)
The specific path that water takes through the system
The Correct Model
System 1 is likely more accurate because it models the physical system more precisely. The simple model makes an assumption that the entire retentate loop is perfectly mixed, which may not be true in a real system with a high recirculation rate.
Corrected Simple Model
To make the simple model match System 1, we need to account for the fixed RO feed flow. Here's how we could modify it:
The difference between the models is due to how they handle the recycle loop and fixed RO feed flow. System 1 is more detailed and likely more accurate for a real-world RO system with a high recirculation rate.
For your specific system with:
500 ml/min permeate
200 ml/min drain
4000 ml/min RO feed
90% rejection
The more accurate product conductivity is 253.9 µS/cm, not 280.0 µS/cm.