Certainly! Creating a new cell on an Ericsson EV0 2000 BSC (Base Station Controller) is a multi-step process that involves both planning and configuration. Below is a detailed step-by-step guide for creating a cell on an Ericsson EV0 2000 BSC, typically using the OSS (Operation Support System) or command line interface (CLI) via MML (Man-Machine Language) commands.
Note: The exact steps and commands may vary depending on your OSS version and network configuration. Always ensure you have the necessary permissions and have backed up your configuration before making changes.
Step 1: Gather Required Information
Before you begin, collect all necessary parameters for the new cell, such as:
Cell Name (CELL)
Location Area Code (LAC)
Cell Global Identity (CGI)
Base Station Identity Code (BSIC)
Cell ID
Frequency (BCCH, TCH)
Transceiver (TRX) configuration
Power settings
Neighbor list
Site and sector information
Step 2: Create the Cell in the BSC Database
A. Using OSS (Graphical Interface)
Log in to the OSS.
Navigate to Network Explorer > BSC > Cells .
Right-click on Cells and select Create New Cell .
Fill in all required fields:
Cell Name
Cell ID
LAC
BSIC
BCCH Frequency
TRX configuration
Power levels
Handover parameters
Save the configuration.
B. Using MML Commands (CLI)
1. Define the Cell
plaintext Copy code
RXAPP:MO=RXOTG-<TG_NO>,CELL=<CELL_NAME>,LAC=<LAC>,CI=<CELL_ID>,BSIC=<BSIC>,BCCHNO=<BCCH_FREQ>,TCHNO=<TCH_FREQ>,...;
Replace <TG_NO>, <CELL_NAME>, <LAC>, <CELL_ID>, <BSIC>, <BCCH_FREQ>, <TCH_FREQ> with your actual values.
2. Add Cell to BSC
plaintext Copy code
RXCREATE:CELL=<CELL_NAME>,LAC=<LAC>,CI=<CELL_ID>,BSIC=<BSIC>,BCCHNO=<BCCH_FREQ>,...;
3. Configure TRX for the Cell
plaintext Copy code
RXOTRX:MO=RXOTRX-<TRX_NO>,CELL=<CELL_NAME>,...;
4. Set Power and Handover Parameters
plaintext Copy code
RXMOC:MO=RXOCF-<CELL_NAME>,MAXTXPWR=<VALUE>,...;
Step 3: Configure Neighbor Relations
Add Neighbors to the new cell:
In OSS: Go to the cell’s neighbor list and add required cells.
In CLI:
plaintext Copy code
RXNBRI:CELL=<CELL_NAME>,NBR=<NEIGHBOR_CELL_NAME>,...;
Step 4: Activate the Cell
Activate the cell in the BSC:
In OSS: Right-click the cell and select Activate .
In CLI:
plaintext Copy code
RXACT:CELL=<CELL_NAME>;
Step 5: Verify the Cell
Check the cell status :
In OSS: Check the cell’s operational status.
In CLI:
plaintext Copy code
RXAPP:MO=RXOCF-<CELL_NAME>;
Perform call tests and verify KPIs.
Step 6: Update Documentation
Record all changes in your network documentation and update the cell plan.
Example MML Command Sequence
plaintext Copy code
RXCREATE:CELL=NEWCELL1,LAC=1234,CI=5678,BSIC=63,BCCHNO=45;
RXOTRX:MO=RXOTRX-1,CELL=NEWCELL1;
RXNBRI:CELL=NEWCELL1,NBR=NEIGHBOR1;
RXACT:CELL=NEWCELL1;
Tips & Best Practices
Always double-check parameter values before applying.
Coordinate with RF planning and transmission teams.
Monitor alarms and performance after activation.
Follow your organization’s change management process.
If you need sample parameter values or a template, let me know!