If your GE Reverse Osmosis (RO) system starts constantly draining after each use, especially after changing the filters, there are several potential causes you should check. This issue typically points to a malfunction in the system’s flow or pressure dynamics.
🔧 Common Causes of Continuous Drainage After Filter Change
1. Improper Installation of Filters
- If the filters were not seated properly, or if they were installed in the wrong order, it can disrupt the system's pressure and flow.
- Double-check that all filters are installed correctly and oriented according to the labels (especially the carbon and sediment filters).
2. Air Lock in the System
- When replacing filters, air can get trapped inside the system, preventing proper operation.
- Fix: Run water through the system for several minutes to purge any air bubbles.
3. Faulty Check Valve
- The check valve prevents water from flowing back into the drain line after the tank is full.
- If it was damaged during filter replacement or is faulty, the system may continue to drain constantly.
- Solution: Test or replace the check valve.
4. Defective Flow Restrictor
- The flow restrictor controls how much water goes to the drain versus being stored in the tank.
- If the restrictor was removed, misplaced, or clogged during filter change, it can cause continuous drainage.
- Check: Ensure the flow restrictor is in place and functioning. Some systems have it built into the membrane housing or the drain line.
5. Low Tank Air Pressure
- The RO storage tank has an internal bladder filled with air (usually around 7–8 psi when empty).
- If the pressure is too low, the tank can't push water through the faucet, causing the system to keep running and draining.
- Fix: Use an air pressure gauge to test the tank pressure. Recharge the air bladder if necessary.
6. Leak or Faulty Faucet Valve
- A leak in the faucet or a faulty shut-off valve can trick the system into thinking water is still being used, causing it to keep filtering and draining.
- Check: Look for leaks at the faucet or under-sink connections.
7. Membrane Installed Backwards or Damaged
- If the RO membrane was replaced and installed incorrectly (backwards), it can cause improper flow and constant draining.
- Also, a damaged or defective membrane can allow excessive water to go down the drain.
✅ Steps to Troubleshoot
- Turn off the system and close the tank valve.
- Drain the tank completely by opening the faucet.
- Inspect all filter placements and ensure they're seated correctly.
- Check the flow restrictor — make sure it’s in the correct location and not clogged.
- Test the tank pressure with a tire pressure gauge (should be ~7–8 psi when empty).
- Reopen the valve, let the tank refill, and observe if the system cycles normally.
- If it still drains continuously, consider checking/replacing:
- The check valve
- The flow restrictor
- The membrane
🛠️ Pro Tip
Some GE RO systems have a color-coded or labeled system for filter installation. Refer to your model-specific manual to confirm correct filter placement and orientation.
❗ When to Call a Professional
If you’ve tried all the above and the system still drains continuously, it might be a more complex internal valve or membrane issue. In that case, contacting GE support or a local plumber experienced with RO systems would be advisable.