To determine the energy required for a heat pump + compressor system to create 90 t/h (tonnes per hour) of 6-bar steam from 90°C water at 2 bar, we need to carefully analyze the thermodynamic process. Here's how we can break it down:
Step 1: Define the problem and assumptions
-
Input conditions:
- Water enters at 90°C and 2 bar.
- The desired output is saturated or slightly superheated steam at 6 bar.
-
Output conditions:
- Steam at 6 bar (saturated or slightly superheated).
-
Mass flow rate:
- 90 t/h = 90,000kg/h=25kg/s.
-
Thermodynamic properties:
- Use steam tables or thermodynamic data to find enthalpy values for water and steam at the given pressures and temperatures.
-
Assumptions:
- The process is steady-state.
- No significant heat losses to the surroundings.
- The heat pump + compressor system operates with a coefficient of performance (COP).
Step 2: Thermodynamic analysis
(a) Enthalpy of water at 90°C and 2 bar
From steam tables:
- At 90°C and 2 bar (subcooled liquid), the specific enthalpy (hwater) is approximately:
hwater=376.7kJ/kg.
(b) Enthalpy of steam at 6 bar
At 6 bar:
- Saturated steam has a specific enthalpy (hsteam) of:
hsteam=2756.8kJ/kg.
If the steam is slightly superheated, the enthalpy will be slightly higher, but we'll assume saturated steam for simplicity.
(c) Energy required per kilogram of water
The energy required to convert 1 kg of water at 90°C and 2 bar into steam at 6 bar is the difference in enthalpy:
Δh=hsteam−hwater=
(d) Total energy required for 90 t/h
The total energy required to produce 90 t/h of steam is:
Qtotal=m˙⋅Δh,
where m˙=25kg/s is the mass flow rate.
Substitute the values:
Qtotal=25⋅2380.1=59,502.5kW.
Thus, the total energy required is:
Qtotal=59.5MW.
Step 3: Energy input to the heat pump + compressor system
The heat pump + compressor system does not directly supply all this energy; instead, it uses work input to move thermal energy from a lower temperature source to a higher temperature sink. The efficiency of this process is characterized by the coefficient of performance (COP).
(a) COP of the heat pump
The COP of a heat pump is defined as:
COP=WinQout
where:
- Qout is the heat delivered to the system (in this case, Qtotal=59.5MW).
- is the work input (electrical or mechanical energy required).
Rearranging for Win:
Win=COPQout
(b) Estimating COP
The COP depends on the temperature lift (difference between the condenser and evaporator temperatures). For a heat pump operating between 90°C (water inlet) and ~160°C (temperature of 6-bar saturated steam):
- Assuming a realistic COP of 3–4 for industrial heat pumps.
Using COP=3:
Win=359.5=19.83MW.
Using COP=4:
Win=459.5=14.88MW.
Step 4: Final answer
The energy required by the heat pump + compressor system to create 90 t/h of 6-bar steam from 90°C water at 2 bar is approximately:
14.9to19.8MW
This range depends on the actual COP of the heat pump system.