You've hit on a very common observation about Siemens light rail vehicles (LRVs) like the SD-460 (and similar models like the S70/Avanto, U2, etc., used in many cities). The distinctive "airy howling" or "whirring" sound, especially noticeable from a distance and when the train is accelerating or decelerating, is almost certainly caused by the cooling fans for the traction motors and/or the dynamic braking resistor grids.
Here's why:
-
Traction Motor Cooling: Electric traction motors generate a significant amount of heat, especially under load (acceleration) or when acting as generators (dynamic braking). To prevent overheating, they are equipped with powerful forced-air cooling systems. These systems involve large fans that draw air over the motors.
-
Dynamic Braking Resistor Grids: When the train uses dynamic braking, the traction motors act as generators. The electrical energy produced needs to be dissipated. Some is fed back to the overhead lines (regenerative braking), but excess energy is often shunted to large resistor banks (grids) which convert the electrical energy into heat. These resistor grids get very hot and also require powerful cooling fans to dissipate the heat. These fans are often roof-mounted.
-
The "Howling" Sound: The sound you describe as "airy howling" is characteristic of these large, high-speed fans moving a substantial volume of air through ductwork, grilles, and over the hot components. The specific pitch and "howl" can be due to:
- Fan Blade Design: The shape and number of fan blades.
- Airflow Obstructions: Air passing over fins, grilles, or through tight spaces can create turbulence and specific sound frequencies.
- Resonance: The ductwork or enclosures for these fans can resonate at certain frequencies, amplifying the sound.
- Motor Speed: The fans often ramp up in speed as the cooling demand increases (i.e., during higher power acceleration or harder braking), changing the pitch of the sound.
-
Why "Only Audible From a Distance" and "Not Heard When Close":
- Sound Masking: When you are close to the train, the louder, lower-frequency sounds of the wheels on the rails, the primary motor hum, suspension noises, and general track noise tend to dominate and mask the higher-pitched, more tonal sound of the cooling fans.
- Source Location: The cooling fans and resistor grids are often located on the roof or high up on the car body. Sounds originating higher up can travel further with less obstruction from ground-level objects.
- Attenuation: Lower-frequency sounds (like wheel roar) tend to be more easily absorbed or blocked by the immediate environment. The specific frequency of the fan howl might propagate more effectively over distance under certain atmospheric conditions. As the louder, closer sounds diminish with distance, the persistent fan howl becomes the most prominent sound.
In summary: The "airy howling" is a signature sound of the powerful cooling fans essential for the operation of the electric traction motors and dynamic braking systems on Siemens SD-460s and similar LRVs. The reason it's more noticeable from a distance is largely due to the masking effect of other louder, closer sounds diminishing, allowing the fan noise to become the dominant sound heard.
Your intuition about air resistance against the boxy shape is generally correct for overall wind noise, but the specific, distinctive howl points very strongly to these active cooling systems.