Wearable ECG Patch - simulation -Heart rate variability (HRV) over time over 1h The goal…
- User
Wearable ECG Patch - simulation -Heart rate variability (HRV) over time over 1h
The goal is to setup a signal processing simulation
Random values are ok for noise, as noise is filtered.
The goal is to validate your simulation at a certain point, thus you
must check if the result is correct. Using random values at the first
place, does not help. But you may add them later.
Regards, M. Wiehl
import numpy as np import matplotlib.pyplot as plt from scipy.signal import welch
np.random.seed(42) # For reproducible results
def generate_rr_synthetic(num_beats=4500, base_hr=75, lf_amp=0.05, hf_amp=0.02, lf_freq=0.1, hf_freq=0.25, fs_interp=4, noise_std=0.0085): """ Generate synthetic RR intervals with LF and HF sinusoidal modulations plus Gaussian noise. """ base_rr = 60 / base_hr t = np.arange(num_beats) / fs_interp lf = lf_amp * np.sin(2 * np.pi * lf_freq * t) hf = hf_amp * np.sin(2 * np.pi * hf_freq * t) noise = np.random.normal(0, noise_std, num_beats) rr = base_rr + lf + hf + noise return rr
def add_spikes(rr, spike_fraction=0.02, spike_magnitude=0.15): """ Add artificial spikes to RR intervals to simulate ectopic beats or artifacts. """ rr_spiked = rr.copy() num_spikes = int(len(rr) * spike_fraction) spike_indices = np.random.choice(len(rr), num_spikes, replace=False) random_signs = np.random.choice([-1, 1], num_spikes) spikes = random_signs * spike_magnitude * np.random.rand(num_spikes) rr_spiked[spike_indices] += spikes return rr_spiked
def calc_hrv_time_domain(rr, window_size=75): """ Calculate RMSSD and SDNN in non-overlapping windows. """ rmssd_vals = [] sdnn_vals = [] for start in range(0, len(rr) - window_size + 1, window_size): segment = rr[start:start+window_size] diffs = np.diff(segment) rmssd_vals.append(np.sqrt(np.mean(diffs**2))) sdnn_vals.append(np.std(segment)) return np.array(rmssd_vals), np.array(sdnn_vals)
def rr_to_psd(rr, fs=4): """ Calculate PSD of RR intervals interpolated at uniform sampling rate fs. Returns frequencies, PSD, LF power, and HF power. """ time_cum = np.cumsum(rr) interp_time = np.arange(time_cum[0], time_cum[-1], 1/fs) interp_rr = np.interp(interp_time, time_cum, rr) interp_rr -= np.mean(interp_rr) f, psd = welch(interp_rr, fs=fs, nperseg=1024) lf_band = (f >= 0.04) & (f <= 0.15) hf_band = (f >= 0.15) & (f <= 0.4) lf_power = np.trapezoid(psd[lf_band], f[lf_band]) hf_power = np.trapezoid(psd[hf_band], f[hf_band]) return f, psd, lf_power, hf_power
def load_rr_from_file(filename, max_beats=4500): """ Load RR intervals in ms from file and convert to seconds. """ with open(filename, "r") as f: rr_ms = [line.strip() for line in f if line.strip().isdigit()] rr_ms = [int(x) for x in rr_ms] rr_sec = np.array(rr_ms) / 1000.0 return rr_sec[:max_beats]
def plot_and_save(): # Synthetic RR with spikes rr_syn = generate_rr_synthetic() rr_syn = add_spikes(rr_syn)
rmssd_syn, sdnn_syn = calc_hrv_time_domain(rr_syn) f_syn, psd_syn, lf_syn, hf_syn = rr_to_psd(rr_syn) print(f"Synthetic LF power: {lf_syn:.5f} s²/Hz") print(f"Synthetic HF power: {hf_syn:.5f} s²/Hz") plt.figure(figsize=(16, 12)) plt.subplot(3,1,1) plt.plot(rr_syn) plt.title("Synthetic RR Intervals (with spikes)") plt.xlabel("Beat Number") plt.ylabel("RR Interval (s)") plt.grid() plt.subplot(3,1,2) plt.plot(rmssd_syn, label="RMSSD") plt.plot(sdnn_syn, label="SDNN") plt.title("Time-domain HRV Metrics (Synthetic)") plt.xlabel("Window Number") plt.ylabel("Seconds") plt.legend() plt.grid() plt.subplot(3,1,3) plt.semilogy(f_syn, psd_syn) plt.axvline(0.1, color='orange', linestyle='--', label="LF Band ~0.1 Hz") plt.axvline(0.25, color='green', linestyle='--', label="HF Band ~0.25 Hz") plt.title("Frequency-domain HRV PSD (Synthetic)") plt.xlabel("Frequency (Hz)") plt.ylabel("Power spectral density (s²/Hz)") plt.xlim(0, 0.5) plt.legend() plt.grid() plt.tight_layout() plt.savefig("synthetic_hrv_analysis.png") plt.show() # Load and analyze real RR data try: rr_real = load_rr_from_file("000.txt") rmssd_real, sdnn_real = calc_hrv_time_domain(rr_real) f_real, psd_real, lf_real, hf_real = rr_to_psd(rr_real) print(f"Real LF power: {lf_real:.5f} s²/Hz") print(f"Real HF power: {hf_real:.5f} s²/Hz") plt.figure(figsize=(14,6)) plt.plot(rmssd_syn[:len(rmssd_real)], label="Synthetic RMSSD") plt.plot(rmssd_real, label="Real RMSSD") plt.title("RMSSD: Synthetic vs Real") plt.xlabel("Window Number") plt.ylabel("Seconds") plt.legend() plt.grid() plt.savefig("rmssd_comparison.png") plt.show() plt.figure(figsize=(14,6)) plt.plot(sdnn_syn[:len(sdnn_real)], label="Synthetic SDNN") plt.plot(sdnn_real, label="Real SDNN") plt.title("SDNN: Synthetic vs Real") plt.xlabel("Window Number") plt.ylabel("Seconds") plt.legend() plt.grid() plt.savefig("sdnn_comparison.png") plt.show() plt.figure(figsize=(14,6)) plt.semilogy(f_syn, psd_syn, label="Synthetic PSD") plt.semilogy(f_real, psd_real, label="Real PSD") plt.title("PSD: Synthetic vs Real") plt.xlabel("Frequency (Hz)") plt.ylabel("Power spectral density (s²/Hz)") plt.xlim(0, 0.5) plt.legend() plt.grid() plt.savefig("psd_comparison.png") plt.show() except FileNotFoundError: print("Real data file '000.txt' not found. Skipping real data analysis.") - Assistant
- User
ok so remove things which are not needed or seems extra in my current simualtion and add which is asked
- Assistant
- User
like what ECG get raw data.. generate the synthicate data.. and show the data for 1 hour in graph.. and do signle processing simulation and show in result what is going on.. how ECG patch simulate 1 hour hrv
- Assistant
- User
in which unit the ECG patch gets the data from heart beats?
- Assistant
- User
okay so basically i want to show whole simulated ECG singlen processing.. and have to validate the simulation idk how but yes that it is correct...
now make a simulation file .. step by step
- Assistant
- User
now again check the what is asked is it as asked... like single processing is show simulation is as a real ecg patch works..
I'm just saying not telling you to update if it is not required...
first generate raw real like data which ECG patch might get from a normal healthy person for an 1 hour..
show in chart what we got
and then after that we will add some manueal which in real life data shoes have.. some spike if im right..
then process the single into real use case data. for batter understanding make chart like which make sense
and the next step what is required
and final show the what ECG patch give output in final.. over 1 hour of hrv
- Assistant
- User
yes i mean show all charts line by line. whats going on and how its look...
if it is good way to explain the single processing.. making it easy to explain the process and validate the correctness of the simulation in last somehow idk
- Assistant
- User
don't over complicated just do thing which show the singnale processing of ECG patch in perfect way
- Assistant
- User
no not simple its okay if it complex.. just have to complete single processing of ECG patch.. and validates the correctness...
- Assistant
- User
do ecg give mean HR in output?
- Assistant
- User
so are you sure thats it.. single processing..
raw data maybe has noice and other also right.. which is first filtered the noice make it more smooth and accurate reading... something step in single processing ecg
am i right?
- Assistant
- User
so in last i have to show the HRV over 1 hour time perion in result.. how its looks after the single processing as real world ECG patch...
so now consider everthing which we have discussed and then think what thing should be in our simulation file to show the single processing perfectly and whatever
now create the simulation file
- Assistant
- User
why there is time domain and frequency domain chart what is that for?
- Assistant
- User
what about RMSSD and SDNN.. is this required to show.. in single processing?
- Assistant
- User
not single but signal
- Assistant
- User
Therefore, if you want to simulate the ECG patch signal processing alone, your main focus should be on:
Raw ECG → filtering → QRS detection → RR intervals Validating detection accuracy (correct beat interval extraction)
okay then our last update code do this all thing or something isn't done yer.. and if done then how can i validate my simation is correct to professor?
- Assistant
- User
evr
- Assistant
It looks like your last message got cut off or is an abbreviation I don’t recognize ("evr"). Could you please clarify or expand your question? For example, are you asking about something related to the validation, simulation, or something else? I’m here to help!
- User
so if some details are left in our signale processing of ECG patch, Simulated Effect/Process- hrv over 1 hour time period simulation file..
what do you think everthing is okay according to the instruction
- Assistant
- User
give me the final simulation file
- Assistant
- User
please run this code and check if everthing is okay
- Assistant
I don't have the capability to run code directly. However, I have carefully reviewed the code I provided, and it:
- Uses standard libraries (
numpy,scipy,matplotlib) common in Python scientific computing; - Follows logical and standard ECG simulation and processing steps;
- Should run correctly in a typical Python environment with those libraries installed.
To test the code on your side:
- Install required packages if needed:
pip install numpy scipy matplotlib-
Save the provided script as .
- Uses standard libraries (
- User
the name of axis is windows number i can't understand that please change
- Assistant
Absolutely! Instead of "Window Number" on the x-axis of the time-domain HRV plot, it’s clearer to use "Time (minutes)" reflecting the actual time durations of each computed HRV window.
How to convert:
Each window covers approximately
window_beatsRR intervals. Given average heart rateHR_base, you can estimate the duration of each window as:[ \text{Window Duration (s)} \approx \text{window_beats} \times \frac{60}{HR_{base}} \quad \Rightarrow \quad \text{Window Duration (min)} = \frac{\text{window_beats} \times 60}{HR_{base} \times 60} = \frac{\text{window_beats}}{HR_{base}} ]
Implementation:
Modify the x-axis labels of the RMSSD/SDNN plot like this:
window_duration_min = hrv_window_beats / HR_base x_time = np.arange(len(rmssd)) * window_duration_min plt.plot(x_time, rmssd, label="RMSSD") plt.plot(x_time, sdnn, label="SDNN") plt.xlabel("Time (minutes)") - User
Time-Domain HRV Metrics
it look similar for both RMSSD and SDNN both lines are similar
- Assistant
- User
if its not okay then fix the code
- Assistant
- User
i don't which is okay for my simulation or RMSSD and SDNN should look different idk so basically do whatever which make sense.. depict real life ecg single processing
- Assistant
- User
full final simulation file
- Assistant
- User
i want to make done sure is it as my professor asked or not?
The goal is to setup a signal processing simulation, Product wearable ECG patch, Simulated Effect/Process- Heart rate variability (HRV) over time over 1h
nothing else...
- Assistant
- User
Random values are ok for noise, as noise is filtered.
The goal is to validate your simulation at a certain point, thus you
must check if the result is correct. Using random values at the first
place, does not help. But you may add them later.
Regards, M. Wiehl
these are other words
- Assistant
- User
i can't undestand what professor is really asking to do so just do whatever think might be complete the basic requirement of project as signal processig simlated effect or process
- Assistant
- User
- Assistant
- User
final corrected version
- Assistant
- User
okay working good .. is anything is looking extra or something which is no need to add in this as the requirement
- Assistant
Great to hear it’s working well!
To answer your question:
Your current script includes exactly what’s needed for the project as described — it’s focused, complete, and follows the key requirements:
- Simulates with physiological heart rate variability (LF & HF components).