- Measurement Procedure The instructions in this section shall be performed as described. 9.1. Stress the contact with a 0.0403 inch (1.02 mm) 6-series conductor Prepare a piece of 6-series conductor with a diameter of 0.0403 inch (1.02 mm) +/- 1 percent using the procedure in section 8, “Test Specimen Preparation.” Insert and extract the 6-series conductor into and out of the device under test (DUT) contact five times. Inspect the 6-series conductor for damage to the surface of the conductor. Any surface damage shall be described in the test report. Re-prepare the test specimen as described in section 8, “Test Specimen Preparation.” The resulting test specimen will be shorter than the original. (This test specimen re-preparation is performed after every five insertions to ensure that the original conductor diameter is maintained.) Repeat the above steps until the 6-series conductor has been inserted and removed into the DUT contact a total of 25 times.
- Assistant
- 測試程序
本節中的指示應按照所述進行。
9.1. 使用直徑為0.0403英寸(1.02毫米)6系列導體施加接觸壓力
根據第8節“測試樣本準備”中的程序,準備一段直徑為0.0403英寸(1.02毫米)±1%的6系列導體。
將6系列導體插入和拔出被測試設備(DUT)接觸點五次。
檢查6系列導體的表面是否有損壞。任何表面損壞應在測試報告中描述。
根據第8節“測試樣本準備”中的描述重新準備測試樣本。結果的測試樣本將比原始樣本短。(此測試樣本的重新準備在每五次插入之後進行,以確保保持原始導體直徑。)
重複上述步驟,直到6系列導體插入和拔出DUT接觸點的總次數達到25次。9.2. 使用直徑為0.0250英寸(0.635毫米)線材進行接觸測量
在一段直徑為0.0250英寸(0.635毫米)±1%的銅、銅包鋼或鋼線上準備一個新的端部。如果該線材是同軸電纜的一部分,則準備應使用第8節“測試樣本準備”中的程序。已準備的端部可以每0.25英寸(0.635厘米)標記一次以加快準備時間。
將已準備好的線材插入DUT接觸點。附上力計並以平穩連續的動作將線材從DUT接觸點拔出。參見圖2。
記錄保持力。保持力應至少為50克力。
檢查0.0250英寸的線材有無表面損壞。任何表面損壞應在測試報告中描述。9.3. 使用直徑為0.0320英寸(0.812毫米)59系列導體進行接觸測量
根據第8節“測試樣本準備”中的程序,準備一段直徑為0.0320英寸(0.812毫米)±1%的59系列導體。
將已準備的導體插入DUT接觸點。附上力計並以平穩連續的動作將導體從DUT接觸點拔出。參見圖2。
記錄保持力。保持力應至少為50克力,且最好應至少為150克力。
檢查59系列導體有無表面損壞。任何表面損壞應在測試報告中描述。- 測試額外的DUT樣本
對至少四個額外的DUT樣本重複進行第9節“測試程序”中的所有測試。